OTA Series The OTA series is the second generation of Wi-Fi Sensors from SensoScientific. This series of nodes boasts over-the-air upgrade (OTA) capabilities. This enable the devices to remotely upgrade firmware without the need to be manually serviced. The devices offer a 2.7”...
“Setting Up Your Device” Step 1 – Download App Go to your phone’s app store. Search and download “SensoScientific”. Step 2 – Set Device to Provisioning Mode The OTA device must be configured to the provisioning mode. This is done by turning the device on (put the batteries in). The device screen will flash, and the yellow LED will turn on solid.
Page 4
Step 3 – Connect to Wi-Fi On your cell phone, connect to the Wi-Fi network “mysimplelink-…”. This will connect your phone to the OTA Node. See below for further instructions on how to connect your phone to a Wi-Fi network using an iOS or Android device: From your Home screen, go to Settings >...
Page 5
Step 4 – Configure Wi-Fi Now that you are connected to the OTA node from your cellular phone, go to the SensoScientific app. From the app, go to the Wi-Fi Set-Up link at the bottom of the main screen. Configure to the desired network from this platform.
Page 6
Note: The platform supports enterprise security Once all the appropriate information has been added, select “Join” at the top right of the screen to connect the device to the desired network. If any issues are found while trying to connect or at any time throughout the set-up process, contact technical support: 1-800-279-3101 Support extension - option 4 at the prompt...
Firmware The firmware version line identifies which version of v1.03 Version firmware that the device is using. The Power Supply symbol shows when the device is Power Supply connected to power via Micro USB. This symbol will not show when the power supply is not connected. The Speaker symbol shows whether the audible alarm is on or off.
When the device is connected to the Wi-Fi and can MAC Address Not access the internet, it will show a blinking yellow and red Registered light when the MAC Address is not registered. When the device reads data, which is outside the alarm limits provided in the cloud, an alarm will sound on the Data Alarm device.
Page 9
Silence Speaker: To silence the audible alarm speaker, hold the center button for five seconds. The yellow light will flash until you release. Once the button is released, the yellow light will turn solid and the screen will reset. This will silence the audible alarm until the next time the device wakes up and take a reading.
Page 10
Release the center button but continue holding the right button. The yellow light will remain solid and the green light will flash. Once the green light turns off, release the right button. Rev: 2; By: MB; Date: 06/20/2019 Page 10 of 12...
Page 11
Turn Off Device: To turn off your device. Press and hold the center button for 10 seconds. The screen will flash and turn off. To turn the device back on, press the center button once to reset/wake up the device. Delete Wi-Fi SSID and Password: To clear the memory on the device for the Wi-Fi information that has been configured, follow the steps below:...
Page 12
Phone: 1-800-279-3101 Support extension - option 4 at the prompt Sales extension - option 3 at the prompt Fax: 1-888-238-6002 E-Mail: salesinfo@sensoscientific.com support@sensoscientific.com Click for SensoScientific’s 24/7 Online Help Desk Rev: 2; By: MB; Date: 06/20/2019 Page 12 of 12...