DANGER: DO NOT MIX CHEMICALS! The PowerBase 3070AT Chlorinator system is designed for use with Westlake Water Solu ons approved tablets only. Do not use Cal-Hypo tablets with stabilized chlorine or bromine products, or other sani zing chemicals. Rev 02-05-2021...
Page 2
flip a relay in the electrical box causing the pump to turn on/off as needed. The chlorina on system is designed for use ONLY with Westlake Water Solu ons Accu-Tab Blue SI tablets u lizing the Westlake Water Solu ons erosion feeder technology that erodes only the bo om layer of tablets on the sieve plate, while keeping tablets above the sieve plate dry and ready for use.
Installa on Instruc ons 1. Place the chlorina on system in a loca on near the place of applica on. 2. Level the system. This is important for proper chlorine delivery. 3. Connect the inlet flow meter assembly to the solu on tank. The parts were shipped separately to prevent breakage in shipping.
Page 4
8. If a chemical controller is u lized, plug the controller cord into the controller’s 120v switched output. NOTE: IF A HIGH PRESSURE WEBTROL PUMP IS ORDERED, A LARGER CAPACITY PUMP CONTACTOR IS INSTALLED IN THE ELECTRICAL BOX AND NO CORD/PLUG IS PROVIDED AS A 25 AMP CIRCUIT IS REQUIRED.
Page 5
Start Up 1. Close the discharge gate valve. 2. Open the feed and discharge isola on valves. Water will begin to fill the solu on tank. 3. When water stops flowing, switch the system “ON” using the chemical controller. The pump will circulate water through the black tubing.
Opera on 1. Remove lid from chlorinator and fill with the appropriate amount of Accu-Tab Blue SI tablets. Add no more than the amount of tablets that will be used within one week. 2. Check pool water for desired chlorine level and adjust flow through chlorinator as needed.
Prepara on for cleaning 1. Prepare 2 gallons of muria c acid. 2. Always use appropriate safety equipment while servicing the unit or handling chemicals. 3. Clean the feeder in a well-ven lated area. Chlorine gas may be released during the cleaning process! Inlet/Outlet Bypass To facilitate the cleaning process a Bypass may be installed between the inlet and outlet...
Page 8
Troubleshoo ng System overflows 1. Debris in the float valve. 2. Debris in the check valve. 3. Float valve stuck in down posi on. Clean float valve. Pump will not run. 1. Check power supply and connec ons, and controller 110v signal. 2.
Page 11
For other ques ons, contact Westlake Water Solu ons Technical Service (855-934-3570) for assistance.
Page 12
Cal-Hypo Commercial System Limited Warranty Westlake Water Solu ons warrants (subject to the below condi ons) only its tle to this water treatment system equipment (the "System") and that the System will be free of defects in materials and workmanship for a period of eighteen (18) months from its original shipment date.