Do you have a question about the E300 and is the answer not in the manual?

Questions and answers

Summary of Contents for EcoloxTech E300

  • Page 1 EcoloxTech +1 954-900-6070 sales@ecoloxtech.com...
  • Page 2: Specifications And Requirements

    O PAGE 4 - System Alarms CAUTION! : The recipient/user must acknowledges all risks inherent in the use of O PAGE 5 - Safety Precautions the E300 system and knowledge about proper usage and maintenance. O PAGE 5 - Additive Formulas Specifications & Requirements...
  • Page 3: Buttons And Display

    Buttons and Display Page 3 CAUTION! : This product must be operated or managed by a designated responsible person who has received professional technical training on the proper use and handling procedures of this system. Description LED display System is running Check error code in LED display System RUN On/Off Mode button (see uses below)
  • Page 4: System Alarms

    Settings & Performance Page 4 Flow rate measured in Liters The flow rate can be controlled by tightening or loosening the inflow water valve. A higher flow per minute (L/min) rate will decrease the concentration of free available chlorine (FAC) and a lower flow rate will increase the concentration of FAC.
  • Page 5: Safety Precautions

    Safety Precautions Page 5 * Electrolyzed water contains small quantities of hydrogen (H2), that is released from the solution into the air. Hydrogen, if accumulated, can be explosive. * Electrolyzed water contains free chlorine molecules. Free chlorine molecules have the potential Ventilation to form chlorine gas (Cl2) when the pH of the solution becomes acidic (Below Ph4).
  • Page 6 Changing Additive Page 6 Refill additive tank when low. If additive tank runs dry, the system will stop and display Error 2. • Power Off system • Open the tank storage frontal door. (Lift up first and then open it) •...
  • Page 7 Controlling Concentration Page 7 Formula 1 (Water and food grade salt) Flow rate : 1 L/Min 120 ppm 180 ppm 2 L/Min 96 ppm 140 ppm 3 L/Min 85 ppm 100 ppm 4 L/Min 74 ppm 80 ppm 5 L/Min 52 ppm 65 ppm 6 L/Min...
  • Page 8: Routine Maintenance

    HCI will descale the mineral deposits from the electrolysis cell. Run the system until the actual ampere returns to the set ampere. This could take 30 minutes or several hours depending on the amount of scale. EPA. Establishment # 92405-KOR-1 Ecoloxtech inc Email: sales@ecoloxTech.com Phone: +1 954-900-6070 Webpage: https://ecoloxtech.com...