Sloan DROPSPOT DRS-100 Installation Instructions Manual

Bottle filler with chiller

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS FOR DROPSPOT™
Sloan Valve Company ("Sloan"), warrants its products against defects in materials and workmanship, excluding damage caused by matters beyond Sloan's
reasonable control. Instructions for filing claims can be found in the Limited Warranty which can be obtained at www.sloan.com or by requesting a free copy by
telephone at 888.756.2614. Sloan will repair or replace your defective product, or provide a refund, as your exclusive remedy. This is only a general summary
of Sloan's Limited Warranty so it is important to note that the specific terms, conditions, limitations and exclusions, including the duration of warranty coverage for
your particular Sloan product, are contained in the actual Sloan Limited Warranty. The Limited Warranty is subject to applicable laws in your country, state, province
or other jurisdiction—and disputes arising under the Limited Warranty are to be resolved by binding arbitration unless you provide Sloan with an opt-out notice no
later than 30 days after your purchase date. In case of a conflict with this summary, the terms and conditions set forth in the complete Limited Warranty will prevail.
IMPORTANT INFORMATION
Some options may slightly alter installation. To ensure proper installation, review this document thoroughly and verify rough-ins before beginning any
work. File this document with the owner or maintenance personnel upon completion of installation.
Sloan products are designed in accord with applicable National Codes and Standards, which may include UPC, ANSI, and ASSE. Installers should use industry
standard practice for details not covered within this document. ANSI, UFAS or ADA compliance is subject to the interpretation and requirements of the local code
authority and is the responsibility of the installer for verification.
Prior to installation, supply lines must be flushed of all foreign material such as pipe dope, chips, or solder. Debris or foreign material in water supply
may damage valve. An appropriate thread sealant is recommended on all MPT threaded waste and supply connections to reduce the possibility of leaks. Thread
sealant NOT recommended for slipjoint or gasketed connections.
Industry standard wall backing substrate, for wall hung fixtures, is required. Installer provided wall anchors and wall anchoring hardware must be appropriate for
wall construction and be able to support three (3) times the weight of the unit.
Electrical receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per NEC (National Electrical Code). This fixture is intended to
dispense water that has been lowered in temperature, but otherwise remains unchanged by the materials in the water cooler. It is common for electrical equipment
to be grounded to water lines either within a structure or away from it. Every attempt should be made to prevent this kind of grounding from generating electrical
feedback into the water cooler creating electrolysis. Electrolysis will cause a metallic taste or cause water metal content to increase.
NOTICE: A dielectric coupling must be used to connect the water cooler to the water supply. A nonmetallic coupler is furnished with this water cooler to meet this
requirement.
ON-WALL BOTTLE FILLERS
DRS-100
Bottle Filler with Chiller
®
SLOAN
LIMITED WARRANTY SUMMARY
1
Code No. 68160060
Rev. 2 (09/24)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DROPSPOT DRS-100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sloan DROPSPOT DRS-100

  • Page 1 Sloan Valve Company (“Sloan”), warrants its products against defects in materials and workmanship, excluding damage caused by matters beyond Sloan’s reasonable control. Instructions for filing claims can be found in the Limited Warranty which can be obtained at www.sloan.com or by requesting a free copy by telephone at 888.756.2614.
  • Page 2: Prior To Installation

    • Fixture operates within water pressure range of 20 psi (138 kPa) to 105 • Water supply service stop valve, water connections and electrical psi (724 kPa). Sloan will not warranty product damaged when connected connections to be supplied by others in accordance with local codes.
  • Page 3 3/8” (9.5 mm) OD COPPER 1-1/8” TUBING WATER OUTLET (30 mm) ELECTRICAL KNOCK OUT DIMENSIONAL DRAWING, CHILLER TOP VIEW FRONT VIEW RIGHT SIDE VIEW 15-5/8” (397 mm) 3” (76 mm) REMOVABLE 1-3/4” 3/8” (9.5 mm) OD ACCESS PANEL 2-1/8” COPPER TUBING (44 mm) (54 mm) WATER INLET...
  • Page 4 TUBING AND WATERPATH 36” TUBE ELBOW UNION LENGTH CONNECTOR SHUT-OFF VALVE SOLENOID BOTTLE FILLER SPOUT WATER FILTER LOCATION IF USED TUBE UNION CONNECTOR TO BUILDING 35" TUBE LENGTH WATER SUPPLY SHUT-OFF VALVE, WATER ACTIVATED CHILLER...
  • Page 5: Electrical Requirements And Connections

    COLLET DISCONNECTING THE TUBE To disconnect the tube from the fitting, ensure that the water line is depressurized. Use the Sloan Universal Maintenance Tool to push collet square/evenly towards the push-in fitting body and hold. While holding the collet in, pull on the tubing to remove from the push-in fitting.
  • Page 6: Installation Preparation

    1 – INSTALLATION PREPARATION IMPORTANT: Prior to Bottle Filler installation, adequate structural support in or behind the wall, water supply, drain, and electrical must be installed. All plumbing should be installed in accordance with applicable codes and regulations. All electrical wiring should be installed in accordance with national and local codes and regulations.
  • Page 7 2 – INSTALL CHILLER, CONTINUED Connect Chiller electrical. Install Tube Union Push-In Adapters onto Chiller inlet and outlet. Locate Chiller where there is 4" of space in front and above the Chiller for proper ventilation. Make sure the supply power is off. Remove front panel of Chiller and make the necessary electrical connections per the Chiller data label including the ground connection.
  • Page 8: Make Connections

    4 – MAKE CONNECTIONS Connect the bottle filler power supply to the pigtail connection on With unit attached to wall, and bottle filler assembly open, install the back of the control board and plug power supply into electrical P-Trap waste outlet (not provided). outlet.
  • Page 9: Care And Cleaning

    Use only a mixture of clean water and a mild detergent to clean unit weekly or more often as needed. For best results, always rinse well with fresh water and wipe completely dry with a clean soft cloth. DO NOT USE harsh chemicals, abrasive, or petroleum based cleaners. Use of these will void the Sloan warranty. To remove stubborn water marks or minor scratches, apply a stainless steel cleaner/polish to a synthetic abrasive pad and carefully rub the panel with the grain.
  • Page 10: Troubleshooting Guide

    (opposite to the direction shown by the arrow on the side of the solenoid valve) through the solenoid valve. Reconnect the compression fittings in the correct orientation. When assistance is required, please contact Sloan 4. BACKLIT LEDS ARE OFF OR FLICKERING: Technical Support at 1.888.SLOAN.14 or 1.888.756.2614.
  • Page 11: Parts List

    The information contained in this document is subject to change without notice. SLOAN • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131 Phone: +1.800.9.VALVE.9 or +1.800.982.5839 • Fax: +1.800.447.8329 • www.sloan.com Copyright ©...

Table of Contents