Download Print this page
HIKVISION 2000VA Manual
HIKVISION 2000VA Manual

HIKVISION 2000VA Manual

Advertisement

Quick Links

MODEL
110V: 110/115/120VAC;
110V: 85~145 VAC;
110V: 110/115/120VAC;
110V: 102~132 VAC;
Battery rating
To test the UPS on battery mode, cut off the utility and UPS observes
"backup indicator" lights, then your PC can continue working normally.
1. Self-testing while switching on
Push the switch for 3 seconds, (the LCD displayinput & output voltage).
then the UPS will be ready for operation.
2. Silence Function
In Battery Mode, shortly press the switch will enable or disable the buzzer.
But when UPS is low battery or overloaded, the buzzer can not be silenced.
3. Autorun
In DC mode, UPS discharges till battery run out and cut off, UPS autorun
when AC recover.
4. Overload protection
When UPS is overloaded on operation, it will cut off the output
automatically if it is not solved by the user in time.
5. Low battery shut off
When the battery is about to be exhausted, UPS will shut down automatically
to protect battery s life.
6. Switching off
1) AC Normal
UPS will cut off the output and goes to AC standby mode by pressing the
switch for 3 seconds.
2) Backup
Press the switch for 3 seconds, the UPS will be turned off after a long beep.
2000VA
3000VA
220V: 220/230/240VAC
220V: 175~275VAC
45~65Hz
220V: 220/230/240VAC
220V: 200~240VAC
12V /9Ah x4
12V /9Ah x 2
8
The trouble shooting chart covers most of the difficulties that you may
encounter under normal working conditions. If the UPS fails to operate
properly, please review the following steps before calling the service center.
1. Is the UPS plugged into a correct working outlet?
2. Is the line voltage within the rating specified?
3. Is the fuse or breaker / ciruit protector on back panel open?
1. Model No. & Serial No.
2. Date of problem.
3. Full description of problem.
The buzzer beeps every
8 seconds
The buzzer beeps every
1 second
COMMUNICATION SOFTWARE DOWNLOAD
Communication software download address:
https://www.hikvision.com/en/support/download/software/
ups-software/
S/N:PN-CC625-70033-08D10-08140

Advertisement

loading
Need help?

Need help?

Do you have a question about the 2000VA and is the answer not in the manual?

Questions and answers

Summary of Contents for HIKVISION 2000VA

  • Page 1 The trouble shooting chart covers most of the difficulties that you may 2000VA 3000VA MODEL encounter under normal working conditions. If the UPS fails to operate properly, please review the following steps before calling the service center. 110V: 110/115/120VAC; 220V: 220/230/240VAC 1.
  • Page 2 1 .With the UPS unit off and unplugged, connect the computer, monitor, and any extemally powered data storage device Zip drive Jazz drive Tape drive)etc. Into the battey power supplied outiets. DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into the battery power supplied outlets.

This manual is also suitable for:

3000vaDs-ups2000-auDs-ups3000-au
Save PDF