GRAFIK Systems
Installation Instructions
Occupant Copy
Features
GRX-IO
• Integrates a GRAFIK Eye lighting control system with
equipment that has contact-closure I/O, including:
- Motion and occupant sensors.
- Timeclocks and push buttons.
- Motorized projection screens, skylights, window shades,
and movable walls.
- AV equipment.
- Security systems.
• May be programmed to control any combination of one to
eight GRAFIK Eye 3000 or 4000 Series control units.
Inputs/Outputs:
• Provides five inputs and five outputs.
• Provides both normally open (NO) and normally closed
(NC) dry contacts.
• Using the inputs, contact closures in other equipment can
operate control units to:
- Select scenes.
- Run sequences (loop through scenes).
- Lock control units.
- Activate panic mode (lights go full on).
- Adjust scenes to reflect status of movable walls.
- Turn lights on or off based on room occupancy.
• Using the outputs, scene changes in control units can:
- Trigger outputs to control other equipment.
- Provide status feedback to other equipment.
Four Types of Configuration:
1.4S Scene Selection Control: Provides for remote control of
GRAFIK Eye 3000 or 4000 Series control units. Can be used
to select any group of four scenes and turn the system and
all corresponding lighting off.
Maintain Outputs: Allows the selection of up to 5 contact
closures to other manufacturers' A/V equipment.
Momentary Outputs: Allows the selection of projection
screens or other equipment requiring momentary output
closures.
2.4Q Special Function Control
Sequencing: Cycles the preset light levels from scene 1
through scene 4 (or 5 through 16) and back to scene 1 (or
5) looping indefinitely and using the programmed fade times
for each scene.
Zone Lockout: Prevents modifications to set light levels on
the GRAFIK Eye control unit. Only temporary changes can
be made.
Scene Lockout: Prevents changing of the selected scene
or preset levels on all GRAFIK Eye control unit(s) and
wallstations.
Panic: Activates scene 16 on assigned GRAFIK Eye control
unit(s) and places them in Scene Lockout. Toggle of this
closure will return controls to their status before Panic was
activated.
Please Read
R
GRX-IO and OMX-IO
Control Interfaces
PELV (Class 2: USA) Devices 12 - 24 V
3. 4PS Partition Control: Allows independent (partition
closed) or parallel (partition open) operation of multiple
GRAFIK Eye control units.
4.Occupant Sensor Special Control
OS1 Occupant Sensor Scene 1/Off: maintained
contact so occupant sensor can turn ON assigned
GRAFIK Eye control unit(s) while still allowing scene
changes once room is entered.
Note: Use 4S function if occupant sensor provides a
momentary closure.
OS2 Occupant Sensor Off Only: Occupant must turn
lights on manually, while still allowing energy-saving
benefits.
OMX-IO
• Integrates GRAFIK 5000
TM
7000
, LCP128
, and Softswitch128
TM
®
equipment that has contact-closure I/O, including:
- Motion and occupant sensors.
- Timeclocks and push buttons.
- Motorized projection screens, skylights, window
shades, and movable walls.
- AV equipment.
- Security systems.
• Use the processor panel from one of the systems listed
above to set up the OMX-IO interface for different modes,
functions, and momentary/maintained inputs and outputs.
Inputs/Outputs:
• Provides five inputs and five outputs.
• Provides both normally open (NO) and normally closed
(NC) contacts.
• Using the inputs, contact closures in other equipment
can operate controls to:
- Select scenes.
- Turn lights on or off based on room occupancy.
• Using the outputs, scene changes in control units can:
- Trigger outputs to control other equipment.
- Provide status feedback to other equipment.