User manual
AKKUTEC 4806
1. General ...................................................................................................................... 2
1.1
General safety notes
1.2
Short description
1.3
Intended Use
2
Transportation and storage ..................................................................................... 3
3
Installation and connection ..................................................................................... 4
3.1
Installation
3.2
Connection
3.3
Connection lead accumulator
3.4
Connection of mains voltage
3.5
Connection load
3.6
Circuit diagram
4
Putting into operation .............................................................................................. 9
4.1
Display and messages
5
Operation .................................................................................................................. 9
5.1
Mains operation
5.2
Back-up operation
5.3
Deep discharge protection
5.4
Accumulator circuit monitoring
5.5
Accumulator test
5.6
Temperature tracking (optional)
5.7
Shut-Down
5.8
Acoustic alarm transmitter (optional)
6
Master/Slave-operation at parallel connection ..................................................... 11
6.1
Connection at Master/ Slave-operation
6.2
Signalisierung at Master/Slave-operation:
6.3
Shutdown at Master/Slave-operation
6.4
Configuration Master/Slave
7
Servicing .................................................................................................................. 13
7.1
Testing the lead accumulators
7.2
Exchanging the lead accumulators
8
Decommissioning .................................................................................................... 14
9
Disposal ................................................................................................................... 14
10 Norms and Regulations .......................................................................................... 14
11 Technical Data ......................................................................................................... 15
12 Accessories ............................................................................................................. 16
Snaptec Australia Pty. Ltd.
Email: sales@snaptec.com.au
DC-USV
NBPA1630G01***
http://www.snaptec.com.au
Seite
1/16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AKKUTEC 4806 and is the answer not in the manual?

Questions and answers

Summary of Contents for Snaptec Australia AKKUTEC 4806

  • Page 1 Servicing ........................13 Testing the lead accumulators Exchanging the lead accumulators Decommissioning ....................14 Disposal ........................14 10 Norms and Regulations ..................14 11 Technical Data ......................15 12 Accessories ......................16 Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au 1/16...
  • Page 2 VDE 0510-485-2. Never interconnect new and used lead accumulators, or lead accumulators of different types or from different manufacturers. Used lead accumulators must be disposed carefully Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au 2/16...
  • Page 3: Transportation And Storage

    (see section 11 Technical Data). The units must be pro- tected against humidity and direct sunlight. If lead accumulators are included, they must be recharged at least each half year in case of longer storage. Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au...
  • Page 4: Installation And Connection

    A warning notice "Warning of electrical voltage" -Shut (ASR A1.3 W012) must be attached to the en- Sync closure. Eingang / Input Mounting height: 155.0mm mounting width: 95.0mm mounting depth: 183.0mm (without terminals) Made in Germany www.j-schneider.de Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au 4/16...
  • Page 5 The unit is prepared for protection type I (protective earthing). The operating earth must be con- nected. If this is not observed, touchable parts may carry voltage in case of a fault. There is a danger of fatal electric shock. Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au...
  • Page 6 A connection of plus and minus is absolutely necessary. REFERENCE Used lead batteries must be disposed of in an environmentally friendly manner! Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au 6/16...
  • Page 7 (only at parallel connection) Control input IO-2: 3,4 Shut-Down Control input IO-2: 7 safety monitoring Current-share-bus (only at IO-2: 5 connection in parallel) (The LED’s are linked tot he message contacts with the corresponding names.) Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au 7/16...
  • Page 8 Störung / Fault 0,5A Betrieb / Operation Störung / Fault Netz / Mains OK AKKUTEC 4806 Bat OK IO-2 Temp. Sensor RS232 Shut- Down Current Share CS (Master/Slave) Sync COM1 (Master/Slave) Eingang / Input Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au 8/16...
  • Page 9: Putting Into Operation

    If the final discharge voltage is reached, the consumers are automatically disconnected from the lead accumulators by load rejection. Can be adjusted with the software paraTEC VdS Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au...
  • Page 10 (See section When the AKKUTEC 4806 is delivered it is configurated for three different accumulator dimensions. Herewith the limiting value for the measurement of the internal resistance is adjusted as follows 7 Ah -18 Ah 300 mΩ...
  • Page 11 Bat OK Netz / Mains OK Störung / Fault Betrieb / Operation Störung / Fault Netz / Mains OK Bat OK IO -2 Temp Temp RS232 +Shut -Shut Sync Eingang / Input Temp Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au 11/16...
  • Page 12 A lack of the signal CS results in the overload of the Master, then the Slave only supplies ap- proximately 44 V. All load and all accumulator lines must be connected in parallel each with and connected with separate lines at both AKKUTEC-units. Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au 12/16...
  • Page 13 Ensure the correct fixing of the lead accumulators after re-installation!  NOTE Only use VdS approved lead accumulators. Never use different lead accumulator types, nor lead accumulators of different manufacturers, nor old and new accumulators together. Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au 13/16...
  • Page 14: Norms And Regulations

    Optocoupler to ensure safe isolation primary/sec- EN 60747-5-1, complies with SELV / PELV ondary Power HF transformer to ensure safe separation EN 61558 2-16, complies with SELV / PELV of primary and secondary Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au 14/16...
  • Page 15: Technical Data

    -10 °C … 50 °C Operating temperature / storage temperature ≤95% no condensation Rel. Humidity Max. installation altitude without load reduction 2000 m above sea level .basic parameterization for VRLA-Batteries (AGM, SLA) Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au 15/16...
  • Page 16 (Tu < 15 °C) in order to ensure suffi- cient accumulator charge. • Temperature sensor MTIAQ33G3M01 • Temperature sensor MTIAQ33G3M04 • Temperature sensor MTIAQ33G3M05 Software for PC-aided monitoring and parametrization functions • Windows .NET Framework Software paraTEC VdS Snaptec Australia Pty. Ltd. Email: sales@snaptec.com.au http://www.snaptec.com.au 16/16...