Elid EL2315D User Manual

Door controller
Table of Contents

Advertisement

Quick Links

EL2315D & EL2316D
DOOR CONTROLLER
USER MANUAL
(R1.1.21)
ELID SDN BHD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EL2315D and is the answer not in the manual?

Questions and answers

Summary of Contents for Elid EL2315D

  • Page 1 EL2315D & EL2316D DOOR CONTROLLER USER MANUAL (R1.1.21) ELID SDN BHD...
  • Page 2: Table Of Contents

    Shunt Activation Time 3.1.3 Door Sensor 3.1.4 Push Button 3.1.5 PIN Select 3.1.6 PIN Entry 3.1.7 Valid Buzzer 3.1.8 Door Sensor Debounce 3.1.9Exchange Reader (only on EL2315D) 3.2 CARD MENU 3.2.1 Database Mode 3.2.2 TRANSACTION SIZE 3.2.3 Card Size 3.2.4 Dual Card...
  • Page 3 3.2.5 Auto Lock Release Mode 3.2.6 Special Card Mode 3.2.7 Continuous Swipe Mode 3.3 SENSOR MENU 3.3.1 Sensor Type 3.3.2 Operation Mode 3.3.3 Delay Time 3.3.4 Alarm Duration 3.4 OUTPUT MENU 3.4.1 Output Type 3.4.2 Output Events Command 3.4.3 Output Duration Command 3.4.4 Example of Using EVENT Mode 3.5.1...
  • Page 4 4.3.2 Print Transaction 4.3.3 Second Field 4.3.4 Clear Transactions 4.3.5 Log Transactions 4.4 DOOR MENU 4.4.1 Parameter Menu 4.4.2 Anti-Passback Command 4.4.3 Anti Passback Time Setting 4.4.4 Automatic Lock Release Time Zone Command 4.4.5 Automatic PIN Disable Time Zone Setting 4.4.6 Keypad Lock out Command 4.5 SENSOR MENU...
  • Page 5: El2316D Two Door Controller

    CHAPTER 1 1. EL2316D TWO DOOR Controller INTRODUCTION EL2316D is Elid’s new 2-door controller that replaces EL2207 controller. EL2316D is different from EL2207 in the following ways:- EL2207 consists of a main board plus an expansion board, EL2316D has everything built on a single circuit board whose dimensions and mounting holes are identical to an EL2205.
  • Page 6 Thus, it is an optional board. EL2316D can run without this board in normal operation. ELID offers a wide range of readers that may be used in EL2316D. Some of these are listed below: - Keypad...
  • Page 7: Door Sensor

    EL2315D & EL2316D Door Expansion Kit Manual Chapter 1- Introduction E-NE If the controller is set to "Inhibit Access" mode, then only certain category of users can gain entry. All cards of lower category will not be granted entry, and the display will show "E-NE", Error-No Entry.
  • Page 8 EL2315D & EL2316D Door Expansion Kit Manual Chapter 1- Introduction inputs are connected. EL2316D can support 2 units of EA8 (with 2 inputs and 6 outputs). First EA8 is related to Door 1 and second EA8 is related to Door 2. If your installation does not use these devices, ignore this section.
  • Page 9: Cards

    This output is usually connected to a sounder to alert the occurrence of a break-in. 1.2 CARDS There are 4 types of cards used in ELID EL2316D Access Control System. Master Card : Master Card is supplied with each controller.
  • Page 10: Card Features

    EL2315D & EL2316D Door Expansion Kit Manual Chapter 1- Introduction 1.2.1 Card Features An ELID card is coded with 3 important information; CARD IDENTIFICATION NUMBER (Card ID number, also known as User Number), CUSTOMER CODE (also known as Facility code) and PERSONAL IDENTIFICATION NUMBER (PIN).
  • Page 11: Special Cards

    EL2315D & EL2316D Door Expansion Kit Manual Chapter 1- Introduction 1.2.3 Special Cards Special cards are different from normal User cards in that these cards, apart from being able to open doors can also control output points and arm/disarm sensor alarms.
  • Page 12 EL2315D & EL2316D Door Expansion Kit Manual Chapter 1- Introduction Now key in the point number, which can be from 1 to 6, for any of the 6 outputs, followed by "#" key, and the operation is executed. The display returns to :- SPCL Waiting for the next command to be entered.
  • Page 13: Command Code

    EL2315D & EL2316D Door Expansion Kit Manual Chapter 1- Introduction Note that you can continue the operation as many times as you want without exiting the special programming mode. To exit the special card mode, press "*" key. Following is a summary of the commands: -...
  • Page 14 EL2315D & EL2316D Door Expansion Kit Manual Chapter 1- Introduction ELID EL2316D has powerful features for implementing Time Zone. A calendar clock incorporated inside the controller keeps track of the date, day-of-week and the time. You can program 2 time periods separately for each day of the week (Sunday through Saturday) and a special one for any date declared to be a holiday.
  • Page 15: Installation

    If you decide to use LAN, then you need to purchase a LAN module from ELID. The part number is EA-0079-G02. This module will plug into TCP/IP Module. It has an RJ45 socket allowing you to connect the controller to a standard HUB.
  • Page 16: Miscellaneous Inputs / Outputs

    EL2315D & EL2316D Door Controller Manual Chapter 2 – Installation The third choice is RS485, and we only recommend this mode if you require higher than 9600 bauds of transmission speed, and you do not have large surges on the communication bus. To select this mode, you must set the hardware jumper link to RS485 (default setting is Multidrop).
  • Page 17: Power Supply

    12VDC supply provided from pin 8. Similarly input voltfree contacts can be wired to the sensor inputs using the 12VDCpower source. ELID supplies a standard interface panel fitted with relays and LED display for each output and opto-isolated inputs for the 2 sensor inputs.
  • Page 18: Powering Up El2316D

    EL2315D & EL2316D Door Controller Manual Chapter 2 – Installation The Power Supply must be fed into connector CN9 pins 2 and 1. A fuse rated at 2A is connected immediately after this and feeds all other devices. Note that the 12VDC available at CN1/pin 8, CN4/Pin 4 and CN5/pin 4 are merely for supplying small currents to relays and sensors.
  • Page 19 EL2315D & EL2316D Door Controller Manual Chapter 2 – Installation If you press the <#> key, the screen changes to:- EL2k Swip Pressing the <#> key brings you back to the first screen. The keyboard used on EL2316D consists of 16 keys; most keys have dual functions.
  • Page 20 EL2315D & EL2316D Door Controller Manual Chapter 2 – Installation MC 01 9999 920258 The number you need to enter is “920258” followed by <#>. If you make a mistake, you can correct it by the "<-" (“C”) key. After you have pressed the <#>...
  • Page 21 EL2315D & EL2316D Door Controller Manual Chapter 2 – Installation Press D to select "DISPLAY TYPE" command. The screen will show: - EL2306D SET-UP Disp Type ER5S Pressing the <D> Key causes the setting toggle between ER5S, ER5M, DUAL, ER5. When the desired setting is shown, press the <#>...
  • Page 22 EL2315D & EL2316D Door Controller Manual Chapter 2 – Installation SET CARD SIZE Ofs00 Ln06 Max 17 This command is for setting the data capture window of a Free Format or Wiegand 34+. It is NOT applicable to Wiegand format.
  • Page 23 EL2315D & EL2316D Door Controller Manual Chapter 2 – Installation You can now select commands from either Engineering or User Menu. Revision 1.1.21...
  • Page 24: Engineering Menu Commands

    EL2315D & EL2316D Door Controller Manual Chapter 3- Engineering Menu CHAPTER 3 3. ENGINEERING MENU COMMANDS DOOR MENU COMMUNICATION MENU   LOCK RELEASE TIME BAUD RATE   SHUNT ON TIME (Shun T.) ADDRESS NUMBER   DOOR SENSOR (Dr Ssor) SET LAN ...
  • Page 25: Door Menu

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu 3.1 DOOR MENU Select DOOR Menu, you will notice that the screen changes to: - Shun Push Ssor exit Lock Shunt Door Push Release Activation Sense Button Time Time...
  • Page 26: Lock Release Time (L-R Time)

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu (PIN1/PIN2), PIN Entry (yes/no), Valid Buzzer (yes/no) and Debounce Setting -- have common settings, applicable to both door 1 and door 2, and cannot be set individually for each door.
  • Page 27: Door Sensor

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu In order to change the multiplication factor, press the <D> Key. Each time the <D> Key is pressed the value changes. When the desired value is shown on the screen, press the <#> Key to accept.
  • Page 28: Pin Select

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu 3.1.5 PIN Select When PIN SELECT command selected, the display will show:- Set Door Param PIN Compare PIN 2 PIN 2 is the factory setting. You can choose to use the other PIN Code (PIN 1) by pressing the <D>...
  • Page 29: Door Sensor Debounce

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu Setting the parameter to “YES” will cause the reader buzzer to sound when a valid card is swiped 3.1.8 Door Sensor Debounce This command is applicable for certain locks, which have built-in door sensors.
  • Page 30: Card Menu

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu 3.2 CARD MENU Select Card Menu Command. The display will show: - Dual Size Size Database Transaction Card Size Dual Card Mode Size Database Mode And pressing <#> key, a second screen appears;...
  • Page 31: Transaction Size

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu 3.2.2 TRANSACTION SIZE For firmware version 1.2.40 onwards, added command to select transaction buffer size. If user wished to extend the transaction buffer, then set the transaction database to “extended”.
  • Page 32: Auto Lock Release Mode

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu other words, it requires 2 persons to be present in order to activate the event such as granting door access to a highly secured area controlled by the controller.
  • Page 33: Continuous Swipe Mode

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu And you are required to type in the range Card ID numbers that the controller will recognize as special cards. If CTYPE is selected, then, whether a card is recognized as special card or normal user card depends on how the card is encoded.
  • Page 34: Operation Mode

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu Key whereupon the following screen will appear: - Ssr Oprn Dly Alm Door Enter the sensor for door number ‘01’, the following screen will appear:- Set Sensor Param Ssor Type NO...
  • Page 35 EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu INHB=Inhibit Status Input (such as MOTOR ON/OFF) can be in either state both of that are normal in operation. Alarm Input (such as a Motion Detector) however is normally in Non-alarm State and when it goes to the other state, it is in an abnormal condition and must cause the Sensor Alarm Output to be activated.
  • Page 36: Delay Time

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu 3.3.3 Delay Time The third command for setting sensor input parameter is Delay Time Setting. Press the <C> Key and the screen will show: - Set Alm Trg Dly...
  • Page 37: Alarm Duration

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu seconds before activating the Sounder. A point that is excluded cannot be armed. To set the desired Delay Time, key in the value (in 2 digits) which may be any from 00-99 seconds and press the <#> Key.
  • Page 38: Output Type

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu It can have Time Zone control so that different category of people can use it only during their assigned times. There is a record of its usage in the transaction log.
  • Page 39 EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu In the GP (General-Purpose) mode, the output can be activated manually by means of a special card, or from a PC or by a timer. In the EVNT (event) mode, the output is also activated by an input event, which may be any of the transaction codes recognized by the unit.
  • Page 40: Output Events Command

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu number in succession. pulses programmable. PULSE Each event will cause the output to turn on for a time defined by the command "OUTPUT DURATION". 3.4.2 Output Events Command This command allows you to define what type of activity occurring at the door will trigger a specific output.
  • Page 41: Output Duration Command

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu Invalid Card Output Off Duress Alarm Exclude Sensor Invalid PIN Include Sensor Door Open Alarm Status On (Sensor #1) Pulse Door Open Status Off (Sensor #1) Invalid Customer Code...
  • Page 42: Baud Rate

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu Suppose it is desired to use EL2316D as a time recording terminal, with a buzzer/light to indicate correct swipe and a different buzzer tone for indicating an incorrect swipe.
  • Page 43: Unit Number

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu Press the <A> Key to choose the Baud Rate Setting and the screen changes to: - Set Comm Para Baud Rate 9600 The factory setting is 9600 bauds. You can change the baud rate to any of the following 2400, 4800, LAN, 19200, 38400, COM2 by pressing the <D>...
  • Page 44: Apply Lan Command

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu If you wish to use LAN, you need to set the network parameters using the SET LAN command. When you select the SET LAN command, the following screen appears.
  • Page 45: Test Keypad

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu This menu contains 8 diagnostic test routines for checking the hardware of the controller. The eight commands are displayed in 2 screens as shown below: - Test Test Test...
  • Page 46: Test Input

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu On entering this command, the following display will show:- Reader Test Plse Swipe Card You can swipe card on any of the 4 Readers. The display will be as...
  • Page 47: Test Communication

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu If Key 1 is pressed, the Duress Alarm Output for both EA8 is switched on and the display will show: - > Output Test < 1 GP Output #1...
  • Page 48: Test 7 Segment

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu The first test (echo test) is useful when a PC is linked via EL70 to the controller. You should run a communication program such as HyperTerminal on the PC and set it to behave as a terminal.
  • Page 49: Test Rom

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu Press the <#> Key to commence testing. The unit will automatically test the various pages of memory by first writing data into it, shift the memory up and then down and then reading back what has been written in.
  • Page 50: Clear Memory

    EL2315D & EL2316D Door Controller Manual Chapter 3 – Engineering Menu The screen will show: - Save Memory..Confirm ( * / # ) Press the <#> Key to confirm. Note that in so doing, previously saved parameters are written over with the new data.
  • Page 51: User Menu Commands

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu CHAPTER 4 4. USER MENU COMMANDS DOOR MENU TRANSACTION MENU   PARAMETER MENU VIEW TRANSACTION   ANTI-PASSBACK TIME PRINT TRANSACTION   AUTO LOCK RELEASE SECOND FIELD ...
  • Page 52: Time Menu

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu 4.1 TIME MENU Enter into the TIME MENU. There are five sub-menus. Date light 4.1.1 Set Date To choose the Set Date Command, press the <A> Key, and the following display is shown: - >>>...
  • Page 53: Set Time

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu Sunday Monday Tuesday Wednesday Thursday Friday Saturday When this field is set and the <#> Key is pressed, the Set Date Command is complete and the display jumps back to: - Date 4.1.2 Set Time...
  • Page 54: Set Holiday (Set Hol)

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu 4.1.3 Set Holiday (SET HOL) EL2316D may be programmed to recognize holidays. During such days, a different set of time zones may be activated. A total of 20 holidays may be preprogrammed, using the Set Hol. Command <C>.
  • Page 55: Set Timer

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu 4.1.4 Set Timer A total of 24 timers may be programmed for each door, each timer has two sets of start-stop times. The timers are used in other commands to set time zones.
  • Page 56: Adjust Clock

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu Where D02 signifies Door #2. Repeat the same procedures outlined earlier to enter in the timers needed for door #2. On completion, press the <*> key to return to main menu.
  • Page 57: Card Menu

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu Enter the start date and end date, then set ‘Enable Auto’ to “Yes’ in order to activate the day light saving function. 4.2 CARD MENU Under this menu are the following commands displayed on two screens.
  • Page 58: Delete Cards

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu You can select either to install cards in Door 1 or Door 2. For example, if you wish to select door 2, just key in [ 0 2 <#> ]. If you wish to select door 1, key in [ 0 1 <#>...
  • Page 59: Print Card Database

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu On executing this command, the following screen appears:- View User Cards Door You can select either to view cards in Door 1 or Door 2. For example, if you wish to select door 2, just key in [ 0 2 <#> ]. If you wish to select door 1, key in [ 0 1 <#>...
  • Page 60: Programmable Pin

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu Four digit customer code The 4-digit value may be set as desired to any value between 0001 and 8000. Values between 8000 and 9999 are not allowed. 4.2.6 Programmable PIN...
  • Page 61: Access Time Zone

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu setting of the PIN value is 0000. Note that within each page, the numbers are stored in ascending order. Serial No Card ID PIN Code The first card ID will be shown and the cursor will be placed at the PIN code, and you can enter in any 4 digit number as the new PIN code for the card ID shown.
  • Page 62: Transaction Menu

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu CLEAR DB – will clear database of both doors CLR D1DB – will clear database in door #1 CLR D2DB – will clear database in door #2 4.3 TRANSACTION MENU There are 5 commands in this menu, all of which are related to transactions logged in the controller.
  • Page 63: Print Transaction

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu You can select either to view data in Door 1 or Door 2. For example, if you wish to select door 2, just key in [ 0 2 <#> ]. If you wish to select door 1, key in [ 0 1 <#>...
  • Page 64: Clear Transactions

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu Command. The screen will show: - Send Seconds? Second field OFF You may set the Second field to ON or OFF by pressing the <D> Key. When the desired value is shown, press the <#> Key to accept.
  • Page 65: Door Menu

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu The default setting is to record all events. If you desire to record only selected activities, you should press "D" to change the setting to "NO" followed by <#>. Now the screen will show: -...
  • Page 66: Parameter Menu

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu DOOR MENU PARA MENU Permanent Lock Release Inhibit Access Anti Pass-back PIN Mode ANTI PASS-BACK TIME AUTOMATIC LOCK RELEASE TIME ZONE AUTOMATIC PIN DISABLE TIME ZONE KEYPAD LOCKOUT 4.4.1...
  • Page 67: Anti-Passback Command

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu Door Param Lock Here, “01“ refers to Door 1, and “OFF“ shows that the door is NOT released. To release Door 1, press key <F4> once, and the display will change from “OFF“...
  • Page 68: Anti Passback Time Setting

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu must be installed. Therefore, it is only applicable in single door configuration. 4RDR (4-Reader) – This mode is currently not applicable in EL2305D 4.4.3 Anti Passback Time Setting As explained in Section 4.4.2, one of the Anti-Passback Mode that can be selected uses Time Delay.
  • Page 69: Automatic Pin Disable Time Zone Setting

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu now move to Tuesday and Wednesday. Continue to set the desired timers until all eight days (Sunday through Saturday, plus holiday). The display will then show:- A.L.R. TZ SUN:00MON:00 Where the value “#02”...
  • Page 70: Manual Operation Of Sensing Inputs

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu Functions that can be performed on these points are as follows: - =Sensing is Operational DISARM =Sensing is Disabled EXCLUDE =To remove a sensing point from service (ISOLATE) INCLUDE...
  • Page 71: Automatic Operation Of Sensing Inputs

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu You should enter the sensor number as before. If Arm Sensor Command is selected, then the screen will show: - Sensor Confirm ( * / # ) Press the <#> Key to confirm arming of sensor point. (Press the <*>...
  • Page 72: Output Menu

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu 18:00 23:59 00:00 06:00 Similarly there is another set of Time Zone for Sensor Point # 2: - Sensor TZ 02 SUN:00 MON:00 8 timers may be assigned to it, one for each day.
  • Page 73: On Output Command

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu By timers, set in the command OUTP TZ (Output Time Zone). By EVENTS, which are set in the Engineering Menu. If you do not desire a point to be time controlled, set all the timers to 0 (which is the default setting).
  • Page 74: Set Output Time Zone

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu If Off Output Command is selected, the screen will show: - Off Output Output #1 Output point number This command allows you to turn off an output. 4.6.3 Set Output Time Zone The Set Output Time Zone command allows you to program the 6 outputs to be activated automatically according to timer settings.
  • Page 75: Communication Mode

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu When an output point is under Automatic Timer Control, it can still be overridden by manual control. For example, if output point #1 is set to "come on" between 0800 and 1200 and again between 1300 and 1600, then if at 0900, it is manually turned OFF;...
  • Page 76: Pin Entry Menu

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu 4.8 PIN ENTRY MENU EL2316D allows you to store up to 10 sets of PIN numbers for opening door – without using card. There are 2 commands under this menu. PIN LENGTH sets the number of digits of the PIN code.
  • Page 77: Clear Memory

    EL2315D & EL2316D Door Controller Manual Chapter 4 – User Menu The user must press the <*> key until the display shows “Pin_”, indicating that the controller is ready to read PIN number. The display will show a “-” symbol for each digit keyed in. When the correct number is keyed in, the door lock will be activated, and the display will show “gO”.
  • Page 78: Appendix

    APPENDIX Figure 1 : EL2316D with EK9R/EK8R Keypad+Reader Wiring Revision 1.1...
  • Page 79 Figure 2 : EL2316D sensor & output using EA8 Revision 1.1...
  • Page 80 Figure 3 : EL2306D Multidrop wiring using EL70Q communicator Revision 1.1...
  • Page 81 Figure 4 : EL2306D RS485 wiring using EL70Q communicator Revision 1.1...

This manual is also suitable for:

El2316d

Table of Contents