Summary of Contents for Dracal Technologies USB-I2C-SPS30
Page 1
USB-I2C-SPS30 USB Adapter for SPS30 Particulate Matter Sensor Model name Part number Description USB-I2C-SPS30 612001 USB adapter for SPS30 particulate matter sensor USB-I2C-SPS30 + Sensor 624065 USB adapter for SPS30 particulate matter sensor + Sensirion SPS30 sensor HS code: 8471.60.10.50...
6 Installation and Setup 6 Usage Guidelines and Applications 9 Care, Storage, and Recalibration 9 Troubleshooting Guide and Support 10 Return Process and Warranty Information 10 Accessories and Peripherals 10 Disassembly and Environmental Considerations 11 Document Revision History Dracal Technologies Inc.
It is available upon request to the relevant authorities. Signed for and on behalf of: Dracal Technologies Inc., January 2024 Ariane Garon President Dracal Technologies Inc. USB-I2C-SPS30 – USB Adapter for SPS30 Particulate Matter Sensor...
Overview At Dracal Technologies, we want to democratize access to precision data to engineers and scientists to ease their lives so they achieve their goals more quickly. We believe that precision data should not be compromised by ease of use.
USB port. The SPS30 sensor is powered directly by the USB converter. Our downloadable software automatically identifies the SPS30, enabling real-time data acquisition of all sensor channels. The USB-I2C-SPS30 features a USB communication interface for the PC and an I...
Connect an instrument. Launch DracalView. Verify the instrument appears in the Sources tab. Modify units and decimals in the Configuration tab (Optional). Customize the names of channels to record in the Sources tab (Optional). Visualize data on GraphView. Dracal Technologies Inc.
Page 7
Please refer to the USB-I2C-SPS30 page for the complete guide, specifically the “Software & Documentation” tab. Of note, to log data with DracalView, these are the remaining main steps of the Getting Started guide: Initiate the logging task in the Logging tab.
Page 8
DracalView and the command-line tools. For additional information, please click the relevant link in the Software & Documentation section of the USB-I2C-SPS30 page. Calibration “-CAL” suffix: If present, the product is equipped with a 3-point user-calibration mechanism.
If the instrument has a “-CAL” suffix, it can be adjusted for accuracy during the calibration. The long-term drift of the USB-I2C-SPS30 is 1.25 µg/m3 per year, for concentra- tions of 0 to 100 µg/m . For higher concentrations, it is of 1.25 % m/v per year.
In most cases, there will be an easy solution. In the rare event of a faulty instrument under warranty, Dracal Technologies will proceed to a replacement upon evaluating the situation. The procedure will be explained through email once the customer advises support@dracal.com.
Minimize Energy Consumption: Power down or disconnect the USB sensor when not in use to minimize energy consumption. Document Revision History Version 1.0 2024-02-08 Creation of the User Manual. USB-I2C-SPS30 – USB Adapter for SPS30 Particulate Matter Sensor...
Need help?
Do you have a question about the USB-I2C-SPS30 and is the answer not in the manual?
Questions and answers