Australian Communications and Media Authority (ACMA). Notice! This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. TS1020 Analogue Data Gathering Panel Installation Manual...
Challenger control panels. Analogue data gathering panel (DGP) models are also known as standard DGPs. The TS1020 DGP is part of the Challenger10 system, and may be used with Challenger V8 systems. Note: When used on a Challenger V8 system certain TS1020 DGP functionality may not apply.
Related documentation If used with a Challenger10 panel, refer to the Challenger10 Installation and Quick Programming Manual for information about connecting the TS1020 DGP to a Challenger system. If used with a Challenger V8 panel, refer to the Challenger V8 & V9 Installation and Quick Programming Manual for information about connecting the TS1020 DGP to a Challenger system.
A qualified service person, complying with all applicable codes, should perform all required hardware installation. See Figure 1 below for overall details of a TS1020 DGP installed in a TS0307 Universal Enclosure (supplied). Figure 1: TS1020 board mounted in enclosure 1.
25 mm between the enclosure and any side wall or ceiling. • The TS1020 DGP is powered via a 16 VAC plug pack (supplied). A power outlet (GPO) must be in proximity to the DGP. Only qualified Electricians should provide a GPO.
DGP 6 DGP 22 657 to 688 337 to 352 LAN 2 DGP 7 DGP 23 689 to 720 353 to 368 LAN 2 DGP 8 DGP 24 721 to 752 369 to 384 TS1020 Analogue Data Gathering Panel Installation Manual...
If used with a Challenger V8 panel, the rows marked “LAN 2” in Table 2 on page 5 do not apply. Refer to the Challenger V8 & V9 Programming Manual for input and relay numbering. Connections See on page 7 for the locations of connectors and other items. TS1020 Analogue Data Gathering Panel Installation Manual...
Page 11
Connect the T and C terminals to the panel tamper switch (supplied). Short circuit for sealed, open circuit for unsealed. Must be sealed if not used. Use only normally closed contacts such as the panel tamper switches. Zone input terminals. See “Zone inputs” on page 10. TS1020 Analogue Data Gathering Panel Installation Manual...
Page 12
Fused plug packs cannot be replaced under warranty as the fuse operation can only be caused by a direct short circuit. TS1020 Analogue Data Gathering Panel Installation Manual...
Page 13
12 V Battery The TS1020 DGP should be connected to a 12 V 7.0 Ah battery compliant with AS/NZS 2201.1:2007, Appendix C. Auxiliary power terminals Connect the + and – auxiliary power output terminals to devices that require 12 VDC power, such as detectors. Three sets of auxiliary power output terminals are provided: if you need more than three connections you can use a TS0844 Power Distribution Board to increase the number of terminals.
Page 14
Alternatively, the Challenger system can be configured to monitor zone inputs for two states (sealed and unsealed). This is accomplished by using one 10 kΩ resistor in each circuit, as shown in Figure 5 on page 11. TS1020 Analogue Data Gathering Panel Installation Manual...
Connecting expansion modules Input expansion TS1020 DGPs have eight zone input circuits. The DGP has a cable socket at J7 that may be used to connect (in series) up to three TS0021 or TS1021 eight-input expansion modules to increase the quantity of inputs to 32.
If connected to a Challenger panel ensure the DGP type is programmed as “Standard” in the Challenger Install menu option 4, DGP Database. After power-up, check the Rx and Tx LEDs. See “LED indications” above. TS1020 Analogue Data Gathering Panel Installation Manual...
“Install from a list or specific location” radio button, and then click Next. 7. Click to select the “Search for the best driver in these locations” radio button, and then browse to include the location of the Tecom Firmware Loader application in the search (for example, C:\Program Files\Tecom Firmware Loader\inf_driver).
Page 18
8. Run Tecom Firmware Loader (for example, double-click the file C:\Program Files\Tecom Firmware Loader\tecom-fw-loader_Vn.n.exe). When you run it will tell you if the device is ready, otherwise you can’t select a file. 9. Click Select File… and then browse to the location of the firmware upgrade file on your computer.
Programming guide Introduction TS1020 DGPs have a number of options that are programmable at the time of installation to help integrate the DGP into the local environment. Use the following steps to configure a DGP at address nn (where nn is a DGP address in the range 1 to 15 and 17 to 32).
Page 20
Certain input devices can bounce upon resealing and register nuisance sealed and unsealed changes. You can program a pause for the DGP to wait before reporting inputs as reset via the input reset timer. TS1020 Analogue Data Gathering Panel Installation Manual...
At the Setup DGP Options menu press [2] [ENTER] to display the DGP’s and the battery’s electrical condition. DGP: 13.72V, 0.03A Battery: –0.06A Next or Enter Press [NEXT] to update the display. Press [ENTER] to exit. TS1020 Analogue Data Gathering Panel Installation Manual...
Press [ENTER] to exit. Factory Defaults At the Setup DGP Options menu press [5] [ENTER] to reset the DGP’s programming to default. Restore Factory Defaults? 1–Yes, ENTER–No: Press [1] to restore or press [ENTER] to exit. TS1020 Analogue Data Gathering Panel Installation Manual...