SUPPLEMENTARY DATA
EnPak A60GBHW PDI
The data contained in this supplement is either in addition to or takes exception to data appearing later in this
manual.
ORIGINAL INSTRUCTIONS – PRINTED IN USA
®
EnPak
Pre-Delivery Inspection
Checklist
2023-09
A60 GBHW
FORM: S295530A
© Miller Electric Mfg. LLC 2023-09

Advertisement

loading
Need help?

Need help?

Do you have a question about the EnPak A60 GBHW and is the answer not in the manual?

Questions and answers

Summary of Contents for Miller EnPak A60 GBHW

  • Page 1 The data contained in this supplement is either in addition to or takes exception to data appearing later in this manual. ® A60 GBHW EnPak Pre-Delivery Inspection Checklist ORIGINAL INSTRUCTIONS – PRINTED IN USA © Miller Electric Mfg. LLC 2023-09...
  • Page 2 EnPak A60GBHW ® Pre-Delivery Inspection, Setup, And Testing Check List Customer Company Name: Date: Location/Branch: Customer Contact: Phone: Email: EnPak Serial Number: Truck Chassis: Year: Make: Model: Register your customer’s EnPak at www.MillerWelds.com/registerenpak.  Date: ________________________________________ Name of Up-Fitter Install Representative ________________________________________ Signature of Up-Fitter Install Representative Date:...
  • Page 3: Pre-Delivery Inspection

    Pre-Delivery Inspection Clearances  Top – 24 in. Minimum for top mount fan. Service Side 18 in. Minimum for end mount fan. Fan End  Service Side – 18 in. Minimum  Non-Service Side – 7 in. Minimum  Fan End – 1 in.
  • Page 4 Grounding EnPak  Ground Cable from EnPak to Chassis.  EnPak mechanically bonded to chassis with metal-to-metal contact. Hoses Compressor  ¾ in. ID hose used.  Hose runs direct from EnPak to tank.  20-gallon tank recommended. 10-gallon tank minimum. ...
  • Page 5 Pre-Delivery Setup Compressor ON/OFF Settings Button Start Button Green LED Verify Safety Interlock -Watch Green LED. Should be flashing when Safety Interlock is engaged. Should be OFF when chassis can move. -Press Start button once to turn on Remote. -Press Settings button. -On Settings Screen, select the System Settings option.
  • Page 6 Crane Voltage Threshold For 0V to 12V Step or 0V to 12V Proportional remotes, set to .1V  For IMT Cranes, set higher than .1V For 12V to 0V Proportional remotes, set to slightly less than 12V.  IF unit does not idle down when all loads are off, increase the Crane Voltage Threshold slightly until unit idles down.
  • Page 7 Use of hydraulics Tapping a stick electrode to workpiece (weld equipped units, in stick mode, with Tap To Start Enabled) Chassis battery voltage drops below 12.3 volts  Start the unit with one of the above methods  Set Auto Start/Stop time to desired length Finishing Up ...