No part of this document may be reproduced, distributed, or transmitted in any form or by any means, electronically or mechanically, including photocopying and recording for ® any purpose, without the express written authorization of TORMATIC . Subject to technical modifications. – Variations possible. – The scope of delivery depends on the re- spective product configuration. 2 | Novoferm...
1.1 Contents and target group WARNING These assembly and operating instructions describe the door drive DCC-80 for the versions NHK, SK, ER, SK-WE, NHK-WE (hereinafter referred to as "DCC"). The in- Risk of injury when disregarding the safety information and instructions!
Manufacturer Novoferm tormatic GmbH Eisenhüttenweg 6 D-44145 Dortmund 4 DCC-80 NHK / DCC-80 NHK WE www.tormatic.de with emergency crank handle Specification according to EN 60335-2-103 5 DCC-80 SK / DCC-80 SK-WE The warranty is valid for 2 years or 36000 cycles (whichever is reached first).
Fig. Screw the mounting bracket on the gearbox side facing the door into the sists of the DCC-80 door drive, a control device and the assembly material. holes provided by using two M8 x 20 screws, spring washers and washers. Observe The assembly material usually contains the following components: the tightening torque of 15 Nm.
Page 7
Connection of pulse generator to J1.2 with pulse sequence OPEN-STOP- Fuse 5 x 20 3.15AT CLOSE-STOP... , or to J1.1 with pulse sequence HALF-STOP-CLOSE-STOP... Fig. Connection of ceiling pull switch to J1.2 with pulse sequence OPEN- STOP-CLOSE-STOP... , or to J1.1 with pulse sequence HALF-STOP-CLOSE-STOP... Novoferm | 7...
Page 8
Programming with IPD-E and Programming with IPD-S chapter. 8. Slot J9 – BTD K (optional accessory) The BTD-K (Bluetooth dongle) allows for configuration of the DCC using an APP via Bluetooth. Plug the BTD-K (Bluetooth dongle) into slot J9 as shown in the illustration. The BTD-K is automatically detected. 8 | Novoferm...
5. Confirm the selection with the button to accept the setting parameter and return to the configuration menu. 6. To exit the configuration menu, repeatedly press the or button until the red LED flashes quickly. Novoferm | 9...
You can reset the drive to the default settings in this menu item. To do so, press and STOP Default setting (5 seconds) hold the button for least 5 seconds. The setup wizard is then started automatic- fast STOP Exit menu ally. continu- * Default setting 10 | Novoferm...
9. If you want to complete the programming, press the button repeatedly until – – appears on the 7-segment display (1). 10. Confirm the selection with the button to exit the programming. After 120 seconds of inactivity, the configuration menu is exited. Novoferm | 11...
and buttons. ð Without auto detection: Use the and buttons to select the desired config- uration and briefly press the button to accept the indicated configuration and complete the setting. 12 | Novoferm...
ð Value 55 flashes on the 7-segment display (1). 3. Now press the button on the RSE-T. ð The RSE-R emits a long beep sound for confirmation. ð The drive confirms pairing by the decimal point flashing for 5 times in the LED display. Novoferm | 13...
24 of 40 memory locations are occupied. To delete all codes programmed, proceed as follows: 2. Press and hold the button for 5 seconds. ð Successful deleting the hand-held transmitters is indicated by the decimal point flashing 5 times. 14 | Novoferm...
Stop roll-up protection mechanism at J4.2 Stop roll-up protection mechanism at J4.3 Stop roll-up protection mechanism at J4.2 and J4.3 STOP Exit menu * Default setting Information on the pin assignment can be found in the IPD-S instructions (WN909009-01-6-50). Novoferm | 15...
Page 16
Programming the start button on the radio hand-held transmitter Maintenance cycles reached Programming the 1/2 opening button on the radio hand-held STOP Exit menu transmitter * Default setting Hand-held transmitter information / Deleting all radio codes STOP Hand-held transmitter information STOP 5 seconds STOP Exit menu * Default setting 16 | Novoferm...
Page 17
7000 cycles 7500 cycles 8000 cycles 8500 cycles 9000 cycles 9500 cycles 10000 cycles Overall cycle counter output door Firmware version output – serial number – creation date Reset to default setting STOP 5 seconds STOP Exit menu * Default setting Novoferm | 17...
Once the desired position is reached, con- firm it by pressing and holding the button. The rotation direction can be changed by simultaneously pressing the , button for 3 seconds. 18 | Novoferm...
DCC is set back to normal operation. If the set position is reached, returning to normal operation is only possible by disconnecting the power supply of the DCC. Novoferm | 19...
8.11.1 Emergency operation with emergency crank handle 2 x Photoelectric sensor (J3 / IPD-S) triggered 3 x Cycles per hour reached, let drive cool down This function applies to the DCC-80 NHK and NHK-WE variants. 4 x Supply voltage error (IPD-S) Fig. Insert the crank handle.
Page 21
No door movement Wrong rotation direction detected No door movement Emergency limit switch OPEN approached Retract the door in a de-energised state using the emergency manual override No door movement Travel distance exceeded in time. Check door for ease of motion Novoferm | 21...
1. Loosen the screw and remove the cover (1). 2. Turn the red lever (2) in clockwise direction while disconnecting the drive from the door. ð The door can now be moved by hand and the door movement can be checked. 22 | Novoferm...
Page 23
Model: ................Year of manufacture: ................Serial No................Wing weight: ................Door dimensions: ................Installation and commissioning Company, technician: ................Company, technician: ................Commissioning on: ................Signature: ................Other details Subsequent changes ......................................................................................................................................................... Novoferm | 23...
Page 24
Proof of inspection and maintenance of the door system Date Work performed / necessary measures Test carried out Defects rectified Signature / Signature / company address company address Commissioning, initial check 24 | Novoferm...
Page 25
............Closing edge safety device Function/State ............Documentation by the operating company Rating plate/CE marking complete/readable ............Declaration of Conformity for the door system complete/readable ............Assembly, operating, maintenance manuals complete/readable ............Novoferm | 25...
incorporated into a door system to thus form a complete machine within the meaning Dr. Mathias Machill, Director Operations Novoferm Tormatic of the EC Machinery Directive. The door system must not be put into service until the 13.2 Declaration of Conformity according to Directive 2014/53/EU final machinery has been declared in conformity with the provisions of the EC Ma-...
4.3 Mounting the door drive 14 Figures Types of assembly 4.1 Preparing for installation Tools required 4.2 Opening and closing the housing cover Novoferm | 27...
Page 28
Assembly with mounting bracket Assembly with Universal torque support 15 Nm 28 | Novoferm...
Page 29
4.4 Electrical installation 1. Using additional cable glands 2. Mains connection 5x20 3,15AT 1 x 230 V, N, PE Novoferm | 29...
Page 30
+24 V 5. Input J3 for door connection box 2kΩ 2kΩ 6. Input J4 – Roll-up protection mechanism 4. Input J2 – Photoelectric sensor 7. Slot J5 – Receiver module (optional accessory) LS 2 LS 2 LS 5 LS 5 30 | Novoferm...
Page 31
8. Slot J9 – BTD-K (optional accessory) 8 Operation Emergency operation with emergency crank handle 9. Slot J10 – Option module (optional accessory) 10. Connection J12 – Status relay +24 V GREEN Novoferm | 31...
Page 32
Emergency operation with quick chain Emergency operation with mechanical emergency 32 | Novoferm...