Item no. 14987-5-9970 · ENU · Change 260634 · Approved 2022-06-30 · Page 1 / 11
Operating instructions

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
2
2
2
2
2
2
3
4
4
5
5
5
6
6
6

1.2 Staff qualifications

6
The device may only be transported, unpacked, installed, operated,
6
maintained and otherwise used by suitably qualified, trained and
7
authorized technical staff.
8
Only authorized specialists are permitted to install the device, to carry
9
out a test run and to perform work on the electrical installation.
9
9

1.3 Basic safety rules

9
The safety hazards associated with the device must be assessed again
following installation in the final product.
10
The locally applicable industrial safety regulations are always to be
10
observed when working on the device.
10
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D2D146-AA28-28 and is the answer not in the manual?

Questions and answers

Summary of Contents for ebm-papst D2D146-AA28-28

  • Page 1: Table Of Contents

    Note the following when working on the device: ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 5.2 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions D2D146-AA28-28 WARNING 1.7 Emissions Live terminals and connections even with device WARNING switched off Depending on the installation and operating conditions, Electric shock the sound pressure level may exceed 70 dB(A). → Wait five minutes after disconnecting the voltage at all poles Risk of noise-induced hearing loss before opening the device.
  • Page 3: Intended Use

    Operating instructions D2D146-AA28-28 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions D2D146-AA28-28 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Cable PFA AWG20 (green/yellow AWG18), 6-pole connector housing Molex 46992-0610, 6x socket Molex 39-00-0059 PE (green/yellow) gray (TOP) gray (TOP) black blue brown Item no. 14987-5-9970 · ENU · Change 260634 · Approved 2022-06-30 · Page 4 / 11...
  • Page 5: Nominal Data

    Data obtained at optimum efficiency level. The efficiency values displayed for achieving conformity with the Ecodesign Regulation EU 327/2011 has been reached with defined air duct components (e.g. inlet rings). The dimensions must be requested from ebm-papst. If other air conduction geometries are used on the installation side, the ebm-papst evaluation loses its validity/the conformity must be confirmed again.
  • Page 6: Mounting Data

    Operating instructions D2D146-AA28-28 3.5 Mounting data 4.2 Electrical connection Further mounting data can be taken from the product drawing or Chapter DANGER 4.1 Mechanical connection as required. Voltage on the device Electric shock Strength class of screws → Always connect a protective earth first.
  • Page 7: Plug Connection

    Operating instructions D2D146-AA28-28 4.2.2 Voltage control The motor is provided with a thermal overload protector (TOP). Always check that the thermal overload protector (TOP) is properly connected NOTE before start-up. Failure to connect the thermal overload protector correctly Current overshoots may occur if speed control is implemented will invalidate your warranty claim.
  • Page 8: Connection Diagram

    Operating instructions D2D146-AA28-28 4.4 Connection diagram Note: Change of rotation direction by reversing two phases Δ Delta connection = U1 = black = V1 = blue = W1 = brown 2x gray green/yellow Item no. 14987-5-9970 · ENU · Change 260634 · Approved 2022-06-30 · Page 8 / 11...
  • Page 9: Checking Connections

    Operating instructions D2D146-AA28-28 4.5 Checking connections 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES ; Ensure isolation from supply (all phases). ; Make sure a restart is impossible Do not perform any repairs on your device. Send the device to ebm- ;...
  • Page 10: Cleaning

    Operating instructions D2D146-AA28-28 In the event of further malfunctions, contact ebm-papst. Fastening the Visual inspection At least every Fasten cables 6 months Fastening the Visual inspection At least every Fasten protective earth 6 months 5.1 Cleaning terminal To ensure a long service life, check the fans regularly for proper...
  • Page 11 Electrolytic capacitors ● Dispose of electronic components employing the proper procedures for electronic scrap. → Please contact ebm-papst for any other questions on disposal. Item no. 14987-5-9970 · ENU · Change 260634 · Approved 2022-06-30 · Page 11 / 11...

Table of Contents