4.1 APP download ················································· All rights reserved. 4.2 Register ························································ Growatt has the final right to interpret this user manual. The information 4.3 Sign in and log out ·············································· in this manual is subject to change without notice. 5. EV Charger Internet Configuration·········································...
Product description Wiring definition in the side window Ic+/Ic- 485A/B la+/la- lb+/lb- 1.LOGO and status indicator 2.LCD display 3.RFID ready 4.Start or stop button 1. Terminal block for CT/meter wiring. The terminal 5.Socket outlet(plug holder for cabled version) definition is: 6.Mounting bracket 485A/485B is RS485 terminal for meter connection;...
Packaging list Installation and wiring 3.1 Mount on a wall Name Remark 3.1.1 Open the packaging, you’ll see a EV charger , a mounting bracket, a user manual Charger and a bag of mounting accessories. There is also an RFID card if the EV charger is RFID version.
Page 5
3.2 Mount on a pole 3.1.3 Put the EV charger onto the bracket, and fix it with the 2 screws at the bottom of the EV charger. The installation is done. 3.2.1 Open the package of the pole, take out the pole and mounting accessories. 3.2.2 The pole must be installed on a hard surface, concrete surface is recommended, it can also be mounted on a solid ground.
Page 6
3.2.4 Fix the mounting bracket onto the pole. 3.3 Wiring 3.2.5 Position the EV charger onto the bracket and secure it on the bracket with the 2 3.3.1 The EV charger has 4 power supply wiring, respectively as follows. screws. 400V TN-Grid 3-phase,single phase connection to charger.(L1+N+PE/L2+N+ PE/L3+N+PE) 400V TN-Grid 1-Phase with neutral...
Page 7
230V IT-Grid 1-phase,single phase connection to charger.(L1+L2+PE/L2+L3+ 3.3.2 Set up the power grid after the connection is complete.In the process of PE/L3+L1+PE) switching between different wiring modes, the charger will display the fault(undervoltage), and the fault will disappear after setting the corresponding power grid.(refer to part11 visit “web”...
Users can scan the QR code (Android and IOS ) with the WeChat, or go to the App Store and Google Play to search for ShinePhone or log in to our monitoring website server.growatt.com or server-cn.growatt.com to download. 4.2 Register Before using ShinePhone APP the first time, the user must register an account in advance.
EV Charger Internet Configuration 4.3 Sign in and log out For new users, please click the "+" in the upper right corner of the overview, select “GroHome” and add device (EV Charger), for users who already have had“GroHome” page, go to the “GroHome” page directly and click the "+" in the upper right corner to add device (EV Charger) The user can log in the APP through the existing account and password.
If the users haven’t build the “power plant” before and click “add device”, the app will remind you to add a plant firstly, and the app will allow to “add device” after finishing filling the information of the plant . (a)...
Advanced Setting If the EV charger has an external current sensing device, then click the “advanced”in the WiFi configuration page, and choose the corresponding configuration (CT or meter type, choose the right brand of the meter type, Acrel or Eastron) (a)...
Note: If the users want to set the static IP mode 5.3 4G Configuration 1.Click “go to set” during (d) step and make sure the network cable is disconnected If the EV charger is a 4G model, then the user can click the “skip” directly during 2.Do the hotspot connection, connect to the WiFi whose name is consistent with the page of network configuration methods.
a)Click the AP mode, and enter the hotspot connection, click “next” to switch to Operation instruction and LCD description other pairing mode. b)Connect the WiFi whose name is consistent with the series number of the EV 6.1 Charging mode and Operation charger and click next c)User can check the basic information, and do some basic parameters setting like User can go to the “setting”...
6.2 LCD interface introduction RFID mode: Charging can only be initiated or ceased by swiping RFID card. Interface of standby status. Charging mode is displayed at the bottom centre of the screen. Interface of user card information RFID mode operation process flow Displayed for user to check card ID and balance when swiping RFID card while EV is not connected...
EV Charger WorkModes 7.1 Fast Mode Plug & Charge Interface of fault status. Click “charge” directly and the EV will be charged at maximum power coming from Displayed with fault code and fault a renewable energy source or simply from the grid, especially quick if you’re in a description when fault occurs.
7.2 PV Linkage Mode Charging Capacity Reservation Users can set the target charging capacity(kWh) and the start time through clicking Introduction “energy”, and also can enable “every day” to make it to work following that strategy Driven by solar, charge your car with renewable energy, the EV will be charged by to work all the time the surplus solar power dynamically, combining PV and EV charger together to maximize the solar self-consumption rate and cut your bill.
Page 17
APP Operation The PV linkage mode require the EV charger to connect with an external current sensing device, and choose the corresponding configuration *(CT or meter type, choose the right brand of the meter type, Acrel or Eastron) Black White Black White White...
Page 18
Enabling this function will allow the EV charger to take power from the grid. During the solar power insufficient period, the EV charger will operate according to the default minimum charging power.For single phase EV charger the default value is 1.4kW.As for three phase EV charger, it’s 4.1kW.Once allowing the power take from the grid and set P(kW)value.
Smart Boost Function It’s useful to guarantees EV’s battery capacity before a set time when the off-peak time is not long enough. While users enable the smart boost function and set “pick-up time” and “preset electricity”, the EV charger will charge the EV with a target kWh figured by a set time, it may draw the power from the grid to guarantee the EV’s battery capacity when the off-peak time is not long enough.
Page 20
Black White Black White White Black If meter is used, please wire it as below Black S1 S2...
Other Settings Network setting: network connection method, network mode setting, gateway settings, subnet mask, DNS address The setting page includes basic information, network setting, pile setting, load balancing and authorization management. ●Charger setting: ●Basic information: EV charger ID, EV charger name, country and city, version 1) Charging activation: users can set the charging activation way like APP, RFID, number.
Page 22
●Authorization management: Permissions: it’s useful for authorization management, add and authorize the other account which can use the EV Charger directly ●Force 1-type charge: If your car does not support 3-phase IT/TT grid then ’Force1-type charge’ should ●Version upgrade be activated.Please consult your car dealer to verify if your car support 3-phase Users can check the latest version of the inverter’s firmware and the current IT/TT grid connected charger.
Record Data a)Charging record: The users can read the total charge capacity(kWh) and cost, also the self- Display the serial number of the EV charger, number of the charging gun, start consumption energy and rate by day, month, and year. time, end time,charging time, charging cost, charging capacity, and self- consumption rate b)Appointment record:...
Configuration through internal web 3. Right-click on Local Area Connection and click on Properties. (Service Tool ) After the installation and wiring is done, connect the Charger to a computer and configure parameters via the web browser of the computer, then the Charger can be ready for use. 11.1 Set computer’s IP The Charger’s default IP address is 192.168.1.5.
5. Select "Use the following IP address" and enter the IP address, Subnet Mask, Default Gateway. Click OK and close the Local Area Connection properties window. Overview of Parameter setting page 11.2 Configure parameters Connect the charger to a computer via a network cable. Open the web browser and type in http://192.168.1.5:8080/ in the address field and click enter, then the parameter setting page of the charger will be opened up.
Growatt back-office server via LAN cable and the router has MAC access connected to Growatt back-office server, this ID must be set as the serial number on the control, then you can put this MAC in the router to allow the charger to access server nameplate of the Charger.
Page 27
(15) Set the max output of the charger. (9) PIN of the charger, used to verify the PIN of user card. To use a RFID card with the charger, their PIN must be consistent. If the user card has a different PIN, then it cannot be used on this charger.
Page 28
(23) Over temperature protection value, not suggested to change. (31) This is for communication testing, no need to reset. Fig.20 Fig.25 (24) Charging-allowed time. Charging can only start within this time period. This is used for off-peak charging setting. (33) DC residual current real-time detection value. If you want to charge out of this period, just press the forced on/off button at the side of the charger.
Page 29
There are 2 ways to update firmware for EV charger 3. Open the txt file, write “state=1” in it and save the file. 1. Update by SD card 2. Update on parameter setting page 11.3 Update by SD card The firmware file must be named as “App.bin”. 4.
Page 30
3. Click the ”Browse” button and select the firmware file. Click “Upload”, then update will start automatically. During the update, the LED indicator will behave as below, First flash red and goes out with a short beep sound, during this period the firmware file is transmitted to the charger’s flash memory from the computer;...
Troubleshooting 12.2 Firmware update fails 12.1 Troubleshoot by LED behavior or LCD display 12.2.1 Firmware update failure with SD card: If fault occurs, users can check the fault information on the LCD or by the number of a. Check if the capacity is over 4G bytes,please use a SD card of less than 4G to retry; blinks of the LED indicator light.
Page 32
a. Please check and input the correct WiFi SSID and password to retry; If you check the WiFi setting on the APP, please turn off and back on the charger and connect your mobile to the WiFi emitted by the charger for checking and setting. c.
Page 33
(3). Right-click on Local Area Connection and click on Properties. d. Check if the charger is still connected to the computer. Please unplug it from computer otherwise the charger won’t connect to the back-office server. e. Check if server address is correct in the“Server URL” field. The correct setting is : ws://ess-charge.Growattpower.com:80/ocpp/ws 12.4 Cannot access parameter setting page a.
Page 34
12.5 Charging issue If charging cannot start after the car is plugged in, a. Check if the red emergency stop button is pressed. b. Check what charge mode is being used APP/RFID: Charge can only be started/stopped by APP or RFID card, and the charger must be connected to the back office server already;...
-25℃~ +50℃ Fig14-1. Main circuit diagram Relative humidity 5%~95% Altitude ≤2000m Frequency 50/60Hz 14.2 Contact Communication Ethernet/WIFI/4G Company Name:Shenzhen Growatt new energy Co.,Ltd Charging mode APP/RFID/Plug and charge Address: 4-13F,Building A,Sino-German(Europe) lndustrial Park,Hangcheng Ave,Bao'an Standby power <8W District,Shenzhen,China Standard IEC-62196-2;EN61851 Mounting Website: www.ginverter.com...