Volt Polska SINUS PRO ULTRA-HV 6000 Product Manual

Volt Polska SINUS PRO ULTRA-HV 6000 Product Manual

Solar inverter

Advertisement

Quick Links

PRODUCT MANUAL
SOLAR INVERTER
SINUS PRO
ULTRA-HV 6000
ULTRA-HV 11000
VOLT POLSKA Sp. z o.o.
ul. Swiemirowska 3
81-877 Sopot
www.voltpolska.pl
pomoc@voltpolska.pl | hurt@voltpolska.pl | (58) 500 85 62

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SINUS PRO ULTRA-HV 6000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Volt Polska SINUS PRO ULTRA-HV 6000

  • Page 1 PRODUCT MANUAL SOLAR INVERTER SINUS PRO ULTRA-HV 6000 ULTRA-HV 11000 VOLT POLSKA Sp. z o.o. ul. Swiemirowska 3 81-877 Sopot www.voltpolska.pl pomoc@voltpolska.pl | hurt@voltpolska.pl | (58) 500 85 62...
  • Page 2: Table Of Contents

    ABOUT THIS MANUAL ......................1 Notice...........................1 Purpose ..........................1 Scope ..........................1 SAFETY INSTRUCTIONS ......................1 INTRODUCTION ........................2 Features ..........................2 Basic System Architecture ......................2 Product Overview .........................3 INSTALLATION ........................4 Unpacking and Inspection .....................4 Preparation ..........................4 Mounting the Unit .........................4 Battery Connection .......................5 AC Input/ Output Connection ....................6 PV Connection ....................8 Final Assembly ........................9 Communication Connection ....................10...
  • Page 3: About This Manual

    ABOUT THIS MANUAL Notice The purchased products, services and features are stipulated by the contract made between supplier and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
  • Page 4: Introduction

    INTRODUCTION This is a multi-function inverter/charger, combining functions of inverter, solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
  • Page 5: Product Overview

    Product Overview 97.00MM 97.00MM 12 16 12 16 AC INPUT AC OUTPUT AC INPUT AC OUTPUT PARALLEL CONNECTION PARALLEL CONNECTION 5.2KW parallel model 5.2KW single model 1. LCD display 2. Status indicator 3. Charging indicator 4. Fault indicator 5. Function buttons 6.
  • Page 6: Installation

    INSTALLATION Unpacking and Inspection Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package: The unit x 1 User manual x 1 USB cable x 1 Preparation Before connecting all wirings, please take off...
  • Page 7: Battery Connection

    Install the unit by screwing three screws 97.00MM 97.00MM 97.00MM 97.00MM 97.00MM 97.00MM Battery Connection CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed.
  • Page 8: Ac Input/Output Connection

    3. Insert the ring terminal of battery cable flatly into battery connector of inverter and make sure the bolts are tightened with torque of 2-3 Nm. Make sure polarity at both the battery and the inverter/charger is correctly connected and ring terminals are tightly screwed to the battery terminals. WARNING: Shock Hazard Installation must be performed with care due to high battery voltage in series.
  • Page 9 Please follow below steps to implement AC input/output connection: 1. Before making AC input/output connection, be sure to open DC protector or disconnector first. 2. Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N 3mm. 3.
  • Page 10: Pv Connection

    PV Connection CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules. WARNING! All wiring must be performed by a qualified personnel. WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection.
  • Page 11: Final Assembly

    Please follow below steps to implement PV module connection: 1. Remove insulation sleeve 10 mm for positive and negative conductors. 2. Check correct polarity of connection cable from PV modules and PV input connectors. Then, connect positive pole (+)of connection cable to positive pole (+) of PV input connector.
  • Page 12: Communication Connection

    Communication Connection Please use supplied communication cable to connect inverter and PC. Download the software by link on the first page of this manual into computer and follow on screen instruction to install the monitoring software. For the detailed software operation, please consult the seller if you have any questions. WARNING: It’s forbidden to use network cable as the communication cable to directly communicate with the PC port.
  • Page 13: Operation

    OPERATION Power ON/OFF AC INPUT AC OUTPUT PARALLEL CONNECTION Once the unit has been properly installed and the batteries are connected well, simply press On/Off switch (located on the bottom of the case) to turn on the unit. Operation and Display Panel The operation and display panel, shown in below chart, is on the front panel of the inverter.
  • Page 14: Lcd Display Icons

    LCD Display Icons Function description Icon Input Source Information and Output Information Indicates the AC information Indicates the DC information Indicate input voltage, input frequency, PV voltage, battery voltage and charger current. Indicate output voltage, output frequency, load in VA, load in Watt and discharging current. Configuration Program and Fault Information Indicates the setting programs Indicates the warning and fault codes.
  • Page 15 In battery mode, it will present battery capacity. Load Percentage Battery Voltage LCD Display <1.717V/cell 1.717V/cell~1.8V/cell Load >50% 1.8V/cell~1.883V/cell >1.883 V/cell <1.817V/cell 1.817V/cell~1.9V/cell 50%> Load>20% 1.9 V/cell ~1.983V/cell >1.983 V/cell <1.867V/cell 1.867V/cell~1.95V/cell Load<20% 1.95V/cell~2.033V/cell >2.033 V/cell Load Information Indicates overload. Indicates the load level by 0-24%, 25-49%, 50-74% and 75-100%.
  • Page 16: Lcd Setting

    LCD Setting After pressing and holding "ENTER" button for 2 seconds, the unit will enter setting mode. Press "UP" or "DOWN" button to select setting programs. And then, press "ENTER" or "MENU" button to confirm the selection and exit. Setting Programs: Program Description Selectable option...
  • Page 17 Appliances (default) If selected, acceptable AC input voltage range will be within 90-280VAC. If selected, acceptable AC input voltage range will be within 170-280VAC. AC input voltage range When the user uses the device to connect the generator, select the generator mode.
  • Page 18 Only Solar Solar energy will be the only charger source no matter utility is available or not. If this inverter/charger is working in Battery mode, only solar energy can charge battery. Solar energy will charge battery if it's available and sufficient. Maximum charging current: 80A (default) Setting range is from 1A to 80A for PV...
  • Page 19 24V model default setting: 20.4V If "User-Defined" is selected in program 14, this program can or”LI” be set up. Setting range is from 20.0V to 24.0V for 24Vdc model. Increment of each click is 0.1V. Low DC cut-off voltage will be fixed to setting value no matter what percentage of load is connected.
  • Page 20 Alarm on Alarm off (default) Beeps while primary source is interrupted Record disable Record Fault code click click click Percentage 20﹪(default) Increment of each click is 1%. ﹪ 95﹪(default) ﹪...
  • Page 21: Fault Reference Code

    (default) If "LI" is selected in program 14, program 41 can be set. After the program 41 is set,please restart the inverter to take effect.For example,if you set the program 41 to 0,the inverter can communicate with the must lithium battery.
  • Page 22 Inverter grid current sensor error Inverter load current sensor error Inverter grid over current error Inverter radiator over temperature Solar charger battery voltage class error Solar charger current sensor error Solar charger current is uncontrollable Inverter grid voltage is low Inverter grid voltage is high Inverter grid under frequency Inverter grid over frequency...
  • Page 23: Warning Indicator

    Warning Indicator Warning Code Warning Event Icon flashing Fan is locked when inverter is on. Fan 2 is locked when inverter is on. Battery is over-charged. Low battery Overload Output power derating Solar charger stops due to low battery Solar charger stops due to high PV voltage Solar charger stops due to over load Solar charger over temperature PV charger communication error...
  • Page 24: Operating Mode Description

    Operating State Description Operating State Description LCD display PV energy power is larger than inverter power Match load state PV energy is charger into Note: DC power produced from the battery or convertered your solar array is converted by the inverter to the AC by the inverter into AC power, load which is then sent to your main...
  • Page 25: Display Setting

    Display Setting The LCD display information will be switched in turns by pressing "UP" or "DOWN" key. The selectable information is switched as below order: battery voltage, battery current, inverter voltage, inverter current, grid voltage, grid current, load in Watt, load in VA, grid frequency, inverter frequency, PV voltage, PV charging power, PV charging output voltage, PV charging current.
  • Page 26 Line mode: Circuit Breaker Output Short Circuit Protection Battery mode: Electronic Circuits Efficiency (Line Mode) >95%(Rated R load, battery full charged) 10ms typical (UPS,VDE) 20ms typical (APL) Transfer Time 50ms typical (For parallel operation) Output power derating: 230Vac model: When AC input voltage drops to 95V or 170V depending on models, the output power will be derated.
  • Page 27 Low DC Cut-o ffVoltage @ load < 20% 21.0Vdc 42.0Vdc @ 20% ≤ load < 50% 20.4Vdc 40.8Vdc @ load ≥ 50% 19.2Vdc 38.4Vdc High DC Recovery Voltage 29Vdc 58Vdc High DC Cut-off Voltage 30Vdc 60Vdc Table 3 Charge Mode Specifications Utility Charging Mode INVERTER MODEL 3KW DC24V...
  • Page 28 Charging algorithm for lead acid battery Charging algorithm for Lithium battery Joint Utility and Solar Charging INVERTER MODEL 3KW DC24V 5.2KW DC48V Max Charging Current 80A/100A Default Charging Current 60A/80A Table 4 General Specifications INVERTER MODEL 3KW DC24V 5.2KW DC48V Safety Certification Operating Temperature Range -10°C to 50°C...
  • Page 29: Trouble Shooting

    TROUBLE SHOOTING What to do Explanation / Possible cause Problem LCD/LED/Buzzer LCD/LEDs and buzzer Unit shuts down will be active for 3 The battery voltage is too low 1. Re-charge battery. automatically during seconds and then ( < 1.91V/Cell) 2. Replace battery. startup process.
  • Page 30: Warranty Card

    WARRANTY CARD DATE OF PURCHASE SHIPPING ADDRESS SIGNATURE / STAMP DAMAGE DESCRIPTION SERVICE COMMENTS FILL IN IF NEEDEED (*) Cross incorrect I agree to pay the cost of inverter repair due to: * expiration of the warranty period / * warranty void Before proceeding with the repair, service will inform by phone about the exact costs of the repair.

This manual is also suitable for:

Sinus pro ultra-hv 11000