MECA-INOX R2 Installation And Operating Manual

MECA-INOX R2 Installation And Operating Manual

Flanged 2-piece valve

Advertisement

Quick Links

MECA-INOX
R2 FLANGED 2-PIECE VALVE
INSTALLATION AND OPERATING MANUAL
R2 Flanged 2-Piece Valve
INSTALLATION AND OPERATING
Ref.:
Date:
Edit:
Approval:
MANUAL
UM-2PCS-MANUAL-R2-v0
2024/03/15
JVE
ENE
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R2 and is the answer not in the manual?

Questions and answers

Summary of Contents for MECA-INOX R2

  • Page 1 Ref.: UM-2PCS-MANUAL-R2-v0 MECA-INOX Date: 2024/03/15 R2 FLANGED 2-PIECE VALVE Edit: INSTALLATION AND OPERATING MANUAL Approval: R2 Flanged 2-Piece Valve INSTALLATION AND OPERATING MANUAL...
  • Page 2: Table Of Contents

    Ref.: UM-2PCS-MANUAL-R2-v0 MECA-INOX Date: 2024/03/15 R2 FLANGED 2-PIECE VALVE Edit: INSTALLATION AND OPERATING MANUAL Approval: INDEX Foreword ..........................3 Storage and transport ......................3 Storage ......................... 3 Transport ........................3 Installation manual ......................3 Precautions before installation ..................3 Installation ........................4 Commissioning......................
  • Page 3: Foreword

    Before using the valve, please read the entire manual carefully and ensure everything is clear. If in doubt, please contact Meca-Inox. The R2 2-piece ball valves should be used under service conditions within the range defined by the pressure/temperature diagram (classification is determined by the body and seat materials).
  • Page 4: Installation

    Ref.: UM-2PCS-MANUAL-R2-v0 MECA-INOX Date: 2024/03/15 R2 FLANGED 2-PIECE VALVE Edit: INSTALLATION AND OPERATING MANUAL Approval: Space requirements :  Before positioning the valve on the line, ensure that the pipes do not exert stress on the valve. There should be no misalignment between the upstream and downstream pipes.
  • Page 5: User Manual

    4 User Manual 4.1 Principle The R2 2-piece valve is primarily used for on/off applications. It allows fluid flow when fully open and cuts off the line when closed. Caution: It is not recommended to use the valve in an intermediate position, as this could cause seat deformation and eventually lead to leakage.
  • Page 6: Maintenance

    Ref.: UM-2PCS-MANUAL-R2-v0 MECA-INOX Date: 2024/03/15 R2 FLANGED 2-PIECE VALVE Edit: INSTALLATION AND OPERATING MANUAL Approval: 5 Maintenance Please refer to the maintenance manual. 6 Contact us MECA-INOX 1, rue de la Croix des Maheux 95031 CERGY-PONTOISE CEDEX (France) Tel.: +33 (0) 1 78 47 80 00 Fax: +33 (0) 1 78 47 80 01 Email: infos@meca-inox.com...