USER MANUAL – XSI-PPS- 3K 1. GENERAL SAFETY INSTRUCTION Strictly comply with the safety warnings and advice in this manual, keep it for future reference, and read it carefully before using this equipment. SAFETY AND USAGE WARNING - RISK OF ELECTROCUTION: It is very important and necessary to read the user manual carefully before using the unit.
USER MANUAL – XSI-PPS- 3K 2. SAFETY, QUALITY AND PERFORMANCE STANDARDS EN 61000-6-1 EMC Domestic, Commerce & Small Industries EMC at Industries EN-61000-6-2 EN 61000-6-3 EM Emissions Domestic, Commerce & Small Ind. EN 61000-6-4 EME at Industries Safety AC Inverters for Inverters IEC/EN 62109-1/2 Safety for Li-Ion Batteries IEC 62619...
USER MANUAL – XSI-PPS- 3K 3. PRODUCT DESCRIPTION This unit is a Portable Power Station (PPS) and as such, it includes an intelligent battery system, an intelligent inverter, and a battery charging system that incorporates MPPT technology for maximum efficiency and performance of the system’s batteries. This PPS can receive power from its Solar Input, AC Grid, or even a power generator, both to charge its internal batteries and to power the equipment connected to it.
USER MANUAL – XSI-PPS- 3K 4. PARTS IDENTIFICACION Before installing this unit, verify the following parts are included in its packing: Power Cord Parallel Cable Solar Panels Connectors, with cable (2) Wheel brakes (2) Cable glands (2) Next, all different parts of Portable are displayed, properly identified: TOP VIEW TOP VIEW PARTS IDENTIFICATION...
USER MANUAL – XSI-PPS- 3K 5. INSTALLATION SAFETY INSTRUCTIONS WARNING: Before start checking information in this section, please be advised that checking and understanding safety and warning information from section 1 “Safety Instructions” is absolutely necessary. WARNINGS, RECOMMENDATIONS All installation instructions provided in this manual must be followed, as well as local and national safety regulations. ▪...
USER MANUAL – XSI-PPS- 3K INTERNAL BATTERY CONNECTION For safety reasons, the internal battery of the XSI-PPS-3K comes disconnected from the internal circuitry via the breaker located under the top cover of the equipment. To begin installation, the breaker must be connected as explained below: Start by removing the 2 screws located toward the back of the top panel of the equipment, as shown in the image on the right.
USER MANUAL – XSI-PPS- 3K Connection of the equipment's power cable to the electrical socket and to the outlet where it will be plugged in. SOLAR PANEL CONNECTION Item #19 in the Parts Identification, Section 4 of this manual. IMPORTANT: The overvoltage category of this inverter's solar input is Category II.
Page 10
USER MANUAL – XSI-PPS- 3K Remove the cover of the solar panel connection terminal block, located at the bottom of the rear panel of your XSI-PPS. The location of the securing screw to be removed is indicated in the figure on the right by a red arrow. Install the cable gland included with this equipment on the cover you just removed.
USER MANUAL – XSI-PPS- 3K SPECIFICATIONS AND RECOMMENDED SOLAR PANEL ARRANGEMENTS Please refer to ANNEX 1: SUGGESTED SOLAR PANELS ARRANGEMENT, for a detailed guide on the most recommended panels and configurations for optimal operation of this equipment. AC OUTPUT CONNECTION Via AC Output Sockets: This unit is equipped with AC output sockets on its rear panel.
USER MANUAL – XSI-PPS- 3K Prepare the cables that will be connected to the terminal block of the Centralized 3K Socket. To do this, strip 10 mm from the end of the cables and then trim 3 mm from the Line (L) and Neutral (N) cables.
USER MANUAL – XSI-PPS- 3K PARALLEL CONNECTIONS Your XSI-PPS-3K includes a powerful internal LiFePO4 battery that provides a very useful and versatile battery backup. However, this backup can be expanded by connecting up to 2 additional external batteries in parallel, which, in addition to increasing the system’s backup capacity, connect to the BMS system for enhanced longevity, better operation, greater efficiency, and optimal backup whenever needed.
USER MANUAL – XSI-PPS- 3K 6. KEYBOARD & LCD This unit is equipped with a rechargeable Lithium battery, so it is important to ensure that, before its first use, it is charged for at least 12 hours to guarantee optimal operating conditions. Figure 1 shows the location of the On/Off Button, while Figure 2 shows the XSI-PPS-3K operation panel, consisting of the LCD, Scroll Bar, and operation buttons.
Page 15
USER MANUAL – XSI-PPS- 3K The Scroll Bar allows you to navigate through the different available screens. If confirmation is required (such as in settings), this is done with the circular center area, as shown in Figures 3 and 4: Figure 3 Figure 4 DESCRIPTION OF PAGES ACCESSIBLE FROM THE OPERATION ICONS:...
Page 16
USER MANUAL – XSI-PPS- 3K ICON 2: AC INPUT The icon for this option is shown in the previous figure, and selecting it will display the available screens with information about the AC Input, as shown in the following figures: AC Input Screen 1 AC Input Screen 2 ICON 3: BATTERIES...
Page 17
USER MANUAL – XSI-PPS- 3K The icon representing battery charge displays the State of Charge (SOC) as shown in the following table:: SOC 0% SOC 20% SOC 40% SOC 60% SOC 80% SOC 100% In the CELL BALANCE screen, the small battery icons represent the voltage in the cells, according to the following table: <...
Page 18
USER MANUAL – XSI-PPS- 3K USB Charging Ports: ON USB Charging Ports: OFF ICON 6: LOAD The icon for this option is shown in the previous figure, and selecting it will display the available screens with information about the AC Output, as shown in the following figures: AC Output Screen 1 AC Output Screen 2...
USER MANUAL – XSI-PPS- 3K 7. CONFIGURATION VIA LCD Settings menu allows you to adjust the operating parameters of this device. The factory pre-configured options are shown on the screen as selected. To modify the operating parameters of the XSI-PPS-3K, you must understand its operation. To access the Settings Menu, press the Home Icon (identified in the image on the right) for 3 seconds.
Page 20
USER MANUAL – XSI-PPS- 3K Screen 1/8: Home Page. Allows you to configure which page will be the device's Home page. Default Value: Home. Screen 2/8: Wi-Fi Module Status. Allows you to turn the device's Wi-Fi module on or off. Default Value: Enabled.
Page 21
USER MANUAL – XSI-PPS- 3K Screen 6/8: Event Log Period. Allows you to set the time range during which events will be stored in the device's log. Default Value: 2 Weeks. Screen 7/8: Screen Timeout. Allows you to set the duration for which the device's screen will remain on after the user's last interaction.
Page 22
USER MANUAL – XSI-PPS- 3K Screen 2/17: Nominal Frequency. Allows you to configure the nominal frequency of the device, as shown in the image on the right. Default Value: 60 Hz. XSI-PPS-3K has two periods for managing its AC outputs: Regular and Scheduled. Regular period covers the entire day, except for the time within the Scheduled period.
Page 23
USER MANUAL – XSI-PPS- 3K XSI-PPS-3K has two periods for charging the batteries: Regular and Scheduled. Regular period covers the entire day, except for the time within the Scheduled period. Scheduled period covers the time within the limits set in the next screen (4/17). During both periods, the priority for charging the device’s batteries will be set as configured on the next screen (4/17).
Page 24
USER MANUAL – XSI-PPS- 3K Screen 6/17: State of Charge (SOC) to Resume Battery Discharge. Defines the SOC level at which the batteries must charge to be available for discharge again. The image on the right shows the available options. Default Value: 80%.
Page 25
USER MANUAL – XSI-PPS- 3K Screen 11/17: AC Input Type. Indicates to the device what type of power source is being used to supply it. Default Value: Utility (Grid). Note: The GENERATOR option makes the XSI-PPS more compatible with power delivered by an electric generator.
Page 26
USER MANUAL – XSI-PPS- 3K Screen 15/17: Reset Parameters to Factory Defaults (Critical Function). This function allows resetting the device’s parameters to factory default settings. Due to its operational impact, the first thing it requests is the access code to execute the command.
Page 27
USER MANUAL – XSI-PPS- 3K SCREENS BASED ON OUTPUT POWER PRIORITY Following images show examples of screens based on the configured priority for powering the load (Devices powered by XSI-PPS-3K), along with their respective explanations SUB PRIORITY (Default Value): Load connected to the unit’s output is powered first by the Solar Input, then by the AC Input, and finally by the Batteries, depending on availability.
Page 28
USER MANUAL – XSI-PPS- 3K XSI-PPS-3K uses both solar energy and the AC input to power the load because solar energy alone is insufficient. Batteries are not detected or have a voltage below 18Vdc. USB PRIORITY (Default Value): Load is powered first by the AC Input, then by the Solar Input, and finally by the Batteries, depending on availability. XSI-PPS-3K uses Solar Power to power the load and charge the batteries.
Page 29
USER MANUAL – XSI-PPS- 3K Neither AC input nor Solar Power is present. XSI-PPS-3K uses battery power to supply its output. XSI-PPS-3K uses both AC input and Solar Power to power the load because AC input alone is not sufficient. Batteries are not detected or have a voltage below 18Vdc.
Page 30
USER MANUAL – XSI-PPS- 3K XSI-PPS-3K uses solar energy to power the load, and since it is not sufficient on its own, it simultaneously uses the energy stored in the batteries. AC input is not used because it is not necessary and has the lowest priority. Neither AC input nor solar energy is present.
USER MANUAL – XSI-PPS- 3K 8. OPERATION INSPECTION BEFORE STARTUP Make sure that the unit is properly positioned according to the recommendations in this manual. If there are solar panels in your installation, verify that the cables are securely and firmly connected to their respective terminals. Any loose connection will cause overheating, failures, and equipment damage.
Page 32
USER MANUAL – XSI-PPS- 3K RGB BAR Si se presenta alguna Falla interna del equipo la barra se tornará roja y encenderá de manera fija. Además, la alarma acústica sonará continuamente, a menos que se haya silenciado. This bar constantly displays the status of the XSI-PPS-3K. The location of the RGB Bar on the device is shown to the right, identified as item 12 in Section 4: Parts Identification, as seen in the figure on the right.
Page 33
USER MANUAL – XSI-PPS- 3K Remove the base that was held in place by the screw you just removed, as shown in the image on the right. Take out the filter (foam) from the base where it is located, as shown in the image on the right.
USER MANUAL – XSI-PPS- 3K 9. TECHNICAL SPECIFICATIONS (1/2) XSI-PPS - PORTABLE POWER STATION (1/2) 3K-120V 3K-230V Output Cap. / Cap. de Salida (VA / W) 3000 VA / 3000W 3000 VA / 3000W MAIN FEATURES / FUNCIONALIDADES Built-in Charger / Cargador incorporado MPPT AC-Solar Priority / Prioridad Solar-CA Configurable by LCD - Display...
Page 35
USER MANUAL – XSI-PPS- 3K TECHNICAL SPECIFICATIONS (2/2) XSI-PPS - PORTABLE POWER STATION (2/2) 3K-120V 3K-230V CHARGERS (SOLAR & AC) Solar charger type / Cargador solar MPPT Charging process / Proceso de recarga Smart Specific for LiFePO4 Batteries / Inteligente, Específico para Baterías de LiFePO4 Nominal PV Voltage / Voltaje PV Nominal 230VDC PV Start-up Voltage / Voltaje PV Mínimo...
USER MANUAL – XSI-PPS- 3K ANNEX 1. SUGGESTED SOLAR PANELS ARRAY This Annex explains a suggested solar panel array for XSI-PPS-3K, including the equipment and solar panel data tables, followed by a representation of the calculated arrangement. This is a guide for the calculations that should be performed for each installation to ensure that, based on the individual data of the selected solar panel, the total arrangement meets the key parameters of the equipment, such as: Solar Input Power Maximum DC Voltage (Voc)
Page 37
USER MANUAL – XSI-PPS- 3K ANEXO 2. PARALLEL CONNECTIONS XSI-PPS-3K includes an internal LFP battery that provides a very useful and versatile backup. This backup can be expanded by connecting up to 2 additional external batteries in parallel, which not only increase the backup capacity but also connect to its BMS system to achieve a longer lifespan, better operation, greater efficiency, and optimal backup whenever necessary.
Page 39
USER MANUAL – XSI-PPS- 3K PREPARATION DC Connectors for External Batteries: Item #7 in the Parts Identification, Section 4 of this manual. Top Panel. Parallel Cable Connector: Item #14 in the Parts Identification, Section 4 of this manual. Rear Panel. Since the DC connectors for the external batteries are located on the top panel of the XSI-PPS-3K, underneath the protective cover, the cover must be removed for access, as explained in the following procedure Remove the 2 screws located toward the back of the top panel of the...
Page 40
USER MANUAL – XSI-PPS- 3K XSI-PPS-3K + 1 XBAT-PPS-LFP-2.5KWh XSI-PPS-3K + 1 XBAT-PPS-LFP-2.5KWh Backup Capacity: 5KWh Backup Capacity: 7.5KWh For parallel systems, the following figures illustrate the connection of 1 or 2 external batteries to each of the XSI-PPS-3K: 2 XSI-PPS-3K in Parallel+ 1 XBAT-PPS-LFP-2.5KWh / Backup Capacity: 7.5KWh 2 XSI-PPS-3K in Parallel + 2 XBAT-PPS-LFP-2.5KWh / Backup Capacity: 10KWh www.xmart-ups.com VER.
Page 41
USER MANUAL – XSI-PPS- 3K 2 XSI-PPS-3K in Parallel + 3 XBAT-PPS-LFP-2.5KWh / Backup Capacity: 12.5KWh 2 XSI-PPS-3K in Parallel + 4 XBAT-PPS-LFP-2.5KWh / Backup Capacity: 15KWh NOTE: It is VERY IMPORTANT to maintain the position of the batteries in relation to the XSI-PPS-3K units, as well as the order, orientation, and polarity of the DC cables.
Page 42
USER MANUAL – XSI-PPS- 3K After removing the protective covers from the device, locate the BMS ports of the device, identified as #5 in the image on the right. The two images below show the arrangement for connecting 1 or 2 external batteries to the XSI-PPS-3K. IMPORTANT NOTES: The cable from the first battery goes from the BMS1 port of the XSI-PPS-3K to P1 port of the battery.
Page 44
USER MANUAL – XSI-PPS- 3K 2 XSI-PPS-3K in Parallel + 4 XBAT-PPS-LFP-2.5KWh / Backup Capacity: 15KWh IDENTIFICATION CODE (ID CODE) FOR EACH BATTERY external batteries for each XSI-PPS-3K require a unique identification to communicate properly with the device's BMS. In other words, the codes used cannot be duplicated within the same XSI-PPS-3K.
Page 45
USER MANUAL – XSI-PPS- 3K PARALLEL CONNECTION OF AC OUTPUTS To power devices or complete installations with consumption higher than 3KW, it is necessary to connect the AC outputs of the two XSI-PPS-3K units in parallel to achieve a unified 6KW output in the system. To do this, simply connect the Parallel Connection Ports of both units using the Parallel Cable supplied with the devices.
Page 46
USER MANUAL – XSI-PPS- 3K The other will take the role of Slave, displaying a screen like the one on the right. These roles are random and do not affect operation in any significant way. www.xmart-ups.com VER. 2409.27 (ENG)
Page 47
USER MANUAL – XSI-PPS- 3K ANNEX 3. FAULT & WARNING CODES / TROUBLESHOOTING IMPORTANT: Alarm and fault status are stored in the device's Event Log, along with their numerical codes, date, and description. The code ▪ indicates whether it is a Fault (F) or a Warning (W). WARNINGS: When a warning occurs, in addition to being shown in the Event Log, the following happens: ▪...
USER MANUAL – XSI-PPS- 3K AVAILABLE FAULT CODES Faults can be viewed in the device's Event Log and are accompanied by a continuous audible alarm and continuous red illumination of the RGB bar. This situation should not be handled directly by the user; authorized technical support must be contacted immediately. The following table shows the available fault codes for this device.
Page 49
USER MANUAL – XSI-PPS- 3K TROUBLESHOOTING – WARNING TABLE Alarm Description Cause Solution Alarm Code: W01 Check the AC power supply to the device. Alarm 1 Beep/Sec. Output On. AC Input Not Detected Make sure AC input breaker has not tripped; if it has, reset it RGB Bar flashing red Alarm Code: W02 Check the connection of the solar panels to the device.
USER MANUAL – XSI-PPS- 3K FAULTS TABLE Fault Description Cause Solution Fault Code: F01 Continuous alarm. Output Off. Fan failure Contact technical support to replace the fan. RGB Bar solid red. Fault Code: F02 Continuous alarm. Output Off. PV voltage too high Use a solar panel array with voltage <450Vdc.
USER MANUAL – XSI-PPS- 3K ANNEX 4. WIFI SETTING AND MONITORING VIA APP – i.SOLAR WiFi module in our solar devices (both inverters and power stations) allows the user to have remote control and monitoring through the i.Solar App, available for both IOS and Android devices. All data logs and parameters are stored in the cloud. i.Solar is an application specifically designed for smartphones, so while it can be run on tablets, there may be some changes in style and appearance, although the functions will work the same.
Page 52
USER MANUAL – XSI-PPS- 3K Once communication with the inverter's WiFi network is established, launch the i.Solar application on your phone, and the login screen will appear, as shown in the image on the right. There, click on the "Network Config" button to enter the network configuration that allows the inverter to communicate with the Data server.
Page 53
USER MANUAL – XSI-PPS- 3K Once the data has been transmitted to the XSI-PPS, a pop-up window will appear confirming the success of the operation and offering the option to test the WiFi module's communication with the internet via the network just configured.
Page 54
USER MANUAL – XSI-PPS- 3K Once in the registration area: Enter your Username Password Re-enter your password for confirmation Click the "Register" button to save the account settings. The next time you need to access the App, you will only need to enter the account details you created and click the "Login"...
Page 55
USER MANUAL – XSI-PPS- 3K HOME PAGE The Home page of i.Solar is shown on the right, where the electricity generation graph can be seen. By tapping the Day, Month, Year, or Total tabs, you can view the electricity generation by hours, by days, by months, or the total for the current year, respectively.
Page 56
USER MANUAL – XSI-PPS- 3K By entering the Serial Number of an XSI-PPS and pressing the "Add" button, the device can be added to the App, as shown on the screen to the right. Newly added devices may display the name "unnamed" or their serial number.
USER MANUAL – XSI-PPS- 3K On the screen to the right, the icon to use for deleting any of the inverters from the App is indicated. DEVICE MANAGEMENT By selecting any of the devices listed on the home page, its specific screen will be displayed, showing its real-time data. The data includes battery information (Temperature, SOC, Capacity, Voltages, etc.), Input (Solar and AC), and Output information.
Page 58
USER MANUAL – XSI-PPS- 3K TURNING OFF THE AC OUTPUT: Between the Solar Generation graph and the Output Consumption graph, there is a command to turn the XSI-PPS-3K's output ON/OFF from the App. Simply toggle it and confirm to execute the command. The command is shown at the top of the image on the right, within the red box.
Page 59
USER MANUAL – XSI-PPS- 3K The images in the center and right show the parameter configuration screen, which is divided into Basic and Advanced groups. Following that are the Log and Product groups, which will be explained later. Once the desired changes are made, press the "SAVE" icon to send them to the device and store them. If the process is successful, the message "Send Succeeded"...
Page 60
USER MANUAL – XSI-PPS- 3K From the configuration screen, you can also rename the XSI-PPS-3K. The command is shown in the screen on the right. The result will be the same as when done from the Home screen. This group of functions allows the App to display the different logs available: •...
Page 61
USER MANUAL – XSI-PPS- 3K DATA LOG When selecting the first option, the Data Log is displayed. By default, the report lists all the data for the current day (Today). If the date field is selected, a calendar will appear where you can choose a specific date to review its data.
Page 62
USER MANUAL – XSI-PPS- 3K LOAD CONSUMPTION LOG The third option displays the Log of energy delivered to the load. By default, the report lists generation by year (Year). On the right, the initial screen is shown, and by selecting the field within the red rectangle, you can choose the report format: by Year, Month, or Day.
Page 63
USER MANUAL – XSI-PPS- 3K EVENT LOG – REPOR BY MONTHS If the Date Field, shown inside the red rectangle in the figure on the right, is selected, a list of stored logs organized by month will open. By selecting the desired month and tapping the "OK" icon, the chosen report will be displayed.
Page 64
USER MANUAL – XSI-PPS- 3K Customized Report – Start Date The red rectangle in the first image on the right shows the area to select to choose the Start Date of the report. The second image on the right shows the calendar that appears at the bottom of the screen, where the desired Date can be selected.
Page 65
USER MANUAL – XSI-PPS- 3K PRODUCT This group of functions allows the App to update the device's CPU firmware and display important device information. The options in this group are as follows: • Update • Product Information • Rating Information UPDATE When selecting the Update function, two available options are displayed:...
Page 66
USER MANUAL – XSI-PPS- 3K Firmware Update First screen on the right shows the "Apply" button for this function. Tapping it opens a pop-up window as shown in the second screen on the right, inside the red box. The top box represents the DSP (Main CPU of the inverter).
USER MANUAL – XSI-PPS- 3K Query Update Status The first screen on the right shows the "Query" button for this function. Tapping it opens the second screen on the right, which displays the last firmware update performed on the device, including its date and the status of the operation.
USER MANUAL – XSI-PPS- 3K RATING INFORMATION When selecting the Rating Information function, the main available technical information about the product is displayed, as shown on the screen to the right. CONFIGURATION From the home screen (Home), you can access the configuration screens for the operational parameters of i.Solar App.
Page 69
USER MANUAL – XSI-PPS- 3K Change Password This option allows you to change the password used to log into the App. When selected, the screen on the right appears, where you must enter the current password, then the new password, and re-enter the new password for confirmation.
Page 70
USER MANUAL – XSI-PPS- 3K Language Setting On this screen, you can choose from the available languages: English, Chinese (Traditional and Simplified), and Japanese. www.xmart-ups.com VER. 2409.27 (ENG)
USER MANUAL – XSI-PPS- 3K SUPPORT & WARRANTY XMART XSI inverters feature a powerful internal battery charging system, powered by both the AC input and the solar input. Both inputs can charge the batteries simultaneously or separately, depending on how the inverter is configured. Support: If a failure or problem is detected please check troubleshooting section in user manual.