USER MANUAL – XSI-PPS-1.2K – 2.5K VER. 2409.28 ENGLISH USER MANUAL XSI-PPS-1.2K XSI-PPS-2.5K PORTABLE POWER STATION (PPS) – 230V Technical information on this manual is property of XMART . This manual Information cannot be copied or distributed totally or partially ▪...
USER MANUAL – XSI-PPS-1.2K – 2.5K 1. GENERAL SAFETY INSTRUCTION Strictly comply with the safety warnings and advice in this manual, keep it for future reference, and read it carefully before using this equipment. SAFETY AND USAGE WARNING - RISK OF ELECTROCUTION: It is very important and necessary to read the user manual carefully before using the unit.
USER MANUAL – XSI-PPS-1.2K – 2.5K 2. SAFETY, QUALITY AND PERFORMANCE STANDARDS EN 61000-6-1 EMC Domestic, Commerce & Small Industries EMC at Industries EN-61000-6-2 EN 61000-6-3 EM Emissions Domestic, Commerce & Small Ind. EN 61000-6-4 EME at Industries Safety AC Inverters for Inverters IEC/EN 62109-1/2 Safety for Li-Ion Batteries IEC 62619...
USER MANUAL – XSI-PPS-1.2K – 2.5K 3. PRODUCT DESCRIPTION This unit is a Portable Power Station (PPS) and as such, it includes an intelligent battery system, an intelligent inverter, and a battery charging system that incorporates MPPT technology for maximum efficiency and performance of the system’s batteries. This PPS can receive power from its Solar Input, AC Grid, or even a power generator, both to charge its internal batteries and to power the equipment connected to it.
USER MANUAL – XSI-PPS-1.2K – 2.5K 4. PARTS IDENTIFICACION Before installing this unit, verify the following parts are included in its packing: RS232 Cable (1) Solar Panels Connectors (2) USB Cable (1) Bracket for Power Cord Power Cord Cable Retention Strap Next, all different parts of Portable are displayed, properly identified: TOP VIEW TOP VIEW...
USER MANUAL – XSI-PPS-1.2K – 2.5K 5. INSTALLATION SAFETY INSTRUCTIONS WARNING: Before start checking information in this section, please be advised that checking and understanding safety and warning information from section 1 “Safety Instructions” is absolutely necessary. WARNINGS, RECOMMENDATIONS All installation instructions provided in this manual must be followed, as well as local and national safety regulations. ▪...
USER MANUAL – XSI-PPS-1.2K – 2.5K AC INPUT CONNECTION Item #16 in the Parts Identification, Section 4 of this manual. The following steps explain how to connect the unit to the power grid, thus allowing the XSI-PPS to charge its batteries even when powered off.
USER MANUAL – XSI-PPS-1.2K – 2.5K Connect the other end of the AC power cable to the electrical outlet chosen for this purpose. AC OUTPUT CONNECTION Item #3 in the Parts Identification, Section 4 of this manual. Esta unidad está equipada con 4 tomas de salida AC en su cara superior. Conecte sus dispositivos a estas tomas para ser alimentados por el XSI-PPS.
Page 10
USER MANUAL – XSI-PPS-1.2K – 2.5K Necessary Components (included with the inverter) Male Connector Housing and Female Terminal Female Connector Housing and Male Terminal Necessary Tools (Not included with the inverter, must be suitable for MC4 solar connectors) Crimping Tool Wrench Assembly: Identify the Positive (+) and Negative (-) cables of the solar panel array.
USER MANUAL – XSI-PPS-1.2K – 2.5K Important Notes: Do not touch the terminals of the inverter directly, as there is a risk of exposure to high voltages. When the solar panels are exposed to sunlight, they generate electricity, so they should be handled with caution, keeping in mind that they could be supplying power to the inverter.
USER MANUAL – XSI-PPS-1.2K – 2.5K 6. KEYBOARD & LCD The operation panel of the XSI-PPS is shown on the right, consisting of: LCD, LED, and operation buttons. It is located on the top panel of the unit. LEDS DESCRIPTION: Identification Description On: Output powered from AC input (Online Mode).
USER MANUAL – XSI-PPS-1.2K – 2.5K LCD DESCRIPTION On the right, the LCD screen of this device is shown, which displays all real-time information, divided into 4 operational zones. Below are the details of each operational zone of the LCD screen: ZONE A: AC &...
Page 14
USER MANUAL – XSI-PPS-1.2K – 2.5K ZONE D: POWER FLOW This zone shows the energy flow within the device, as well as the operational states of the different blocks that comprise it. In particular, there are two blocks that we will explain in detail: •...
Page 15
USER MANUAL – XSI-PPS-1.2K – 2.5K SPECIAL ICONS: AC Power Detected Solar Power Detected Overload Power consumption of the devices connected to the XSI-PPS output exceeds its maximum capacity. Muted Alarm Bypass Activated La carga (Load) es alimentada directamente desde la Entrada AC. Rectifier Operating (AC-DC Converter) The battery is being charged from the AC input.
Page 16
USER MANUAL – XSI-PPS-1.2K – 2.5K 3. Solar Input Voltage Solar Input Voltage: 290V The key goes to previous information The key goes to the next information 4. Solar Input Current Solar Input Current: 4.9A The key goes to previous information The key goes to the next information 5.
Page 17
USER MANUAL – XSI-PPS-1.2K – 2.5K Charging Current: 12A Source: AC Input The key goes to previous information The key goes to the next information 7. Battery Charging Power Battery Charging Power, in Watts, from both available sources: AC Input and Solar Input. Charging Power: 400W Source: AC Input + Solar Input Charging Power: 400W...
Page 18
USER MANUAL – XSI-PPS-1.2K – 2.5K 9. Battery Voltage and Output Frequency Battery Voltage: 25.5V Output Frequency: 50Hz The key goes to previous information The key goes to the next information 10. Battery Voltage and Output Frequency Battery Voltage: 25.5V Output Frequency: 50Hz The key goes to previous information...
Page 19
USER MANUAL – XSI-PPS-1.2K – 2.5K Load: 1.10KW Loads of 1KW and above are displayed in KW The key goes to previous information The key goes to the next information 13. Battery Voltage and Discharge Current Battery Voltage: 25.5V Discharge Current: 1A The key goes to previous information The key...
USER MANUAL – XSI-PPS-1.2K – 2.5K 7. OPERATION MODES & LCD These are the operating modes of this unit: Stand-By: Connected to the input power sources (AC and/or Solar), but with the output turned off. Bypass: No solar input available. Grid is present and powers the Load and/or charges the batteries. Inversor: Normal operating mode, with solar and/or grid inputs available, batteries are charged whenever possible, and the devices connected to the inverter are powered as long as the output is not turned off.
USER MANUAL – XSI-PPS-1.2K – 2.5K AC input powers the Output and charges the battery: Battery being charged by both AC input and solar input simultaneously. Output powered by AC input. In this mode, the inverter is connected to If "Solar First" is selected as the priority for powering the Output power sources and has been turned on and the Solar Input is insufficient, AC input supports powering using the ON/OFF switch.
USER MANUAL – XSI-PPS-1.2K – 2.5K Solar Input powers the inverter's output, but it is not sufficient, so the battery supports powering the Load simultaneously: solar input powers the output and charges the battery simultaneously: In this mode, the inverter is powered solely by the solar energy source and has been turned on using the ON/OFF switch.
USER MANUAL – XSI-PPS-1.2K – 2.5K Charging the battery only from AC input: Charging the battery only from Solar input: In this mode, the inverter stops operating; it does not power the output FAULT MODE Charging the battery from both AC and Solar inputs but may charge the battery if its simultaneously: condition allows.
USER MANUAL – XSI-PPS-1.2K – 2.5K 8. CONFIGURATION VIA LCD Before starting the XSI-PPS to power the network of devices that you wish to energize, it is necessary to ensure that it is configured correctly. This can be done from the operation panel, the APP, or via software. This section explains how to do it from the operation panel of the Power Station.
Page 25
USER MANUAL – XSI-PPS-1.2K – 2.5K MAXIMUM CHARGING CURRENT Maximum current to charge the battery. Sum of the current from the AC line and solar input. Default: 15A. Range: 10A, 15A, 20A, 30A VALID AC INPUT RANGE: Allowed valid range for AC input. APL (Default) With this option, valid range for AC input will be from 90 to 280Vac.
Page 26
USER MANUAL – XSI-PPS-1.2K – 2.5K SOC TO SWITCH BACK TO SOLAR INPUT: In Battery Mode, when the battery recharges to this SOC, it switches back to powering its outputs from the Solar Input, if SBU or SOL was selected in parameter 1. Range: 50% - 100%, 1% increments Default: 30% BATTERY CHARGER SOURCE PRIORITY: (For Online, Standby, or Fault...
Page 27
USER MANUAL – XSI-PPS-1.2K – 2.5K BYPASS WITH OVERLOAD IN BATTERY MODE: Bypass Disabled (Default, byd=bypass disabled). If an overload occurs in Battery Mode, the unit will NOT switch to Utility Mode. Bypass Enabled (byE=bypass Enabled). If an overload occurs in Battery Mode, the unit will switch to Utility Mode.
USER MANUAL – XSI-PPS-1.2K – 2.5K 9. OPERATION INSPECTION BEFORE STARTUP Make sure that the unit is properly positioned according to the recommendations in this manual. If there are solar panels in your installation, verify that the cables are securely and firmly connected to their respective terminals. Any loose connection will cause overheating, failures, and equipment damage.
USER MANUAL – XSI-PPS-1.2K – 2.5K 10. TECHNICAL SPECIFICATIONS (1/2) XSI-PPS - PORTABLE POWER STATION (1/2) 1.2K - 230V 2.5K - 230V Output Capacity / Capacidad de Salida (VA) 1200 VA 2500 VA Output Capacity / Capacidad de Salida (W) 1200 W 2500 W MAIN FEATURES / FUNCIONALIDADES...
Page 30
USER MANUAL – XSI-PPS-1.2K – 2.5K TECHNICAL SPECIFICATIONS (2/2) XSI-PPS - PORTABLE POWER STATION (2/2) 1.2K - 230V 2.5K - 230V USER INTERFACE / INTERFAZ CON EL USUARIO Output Power Source, Battery Status, Fault or Warning Status / Fuente de Alimentación de Salida, Estado de las Baterías, Estado de Falla o Alarma AC&PV Inputs, Output, Load (%), Battery level, Charging status (%), Operation mode, etc Valores de entrada AC y Solar, Salida, Consumo, Batería, Cargador, Modo de operación, etc ALARM / ALARMAS...
USER MANUAL – XSI-PPS-1.2K – 2.5K ANNEX 1. SUGGESTED SOLAR PANELS ARRAY Next, for both models of XSI-PPS, the data tables for the equipment as well as the suggested solar panel for each case are shown, followed by the representation of the calculated array. This is a guide for the calculations that should be performed for each installation to ensure that, based on the individual data of the selected solar panel, the total arrangement meets the key parameters of the equipment, such as: Solar Input Power...
Page 32
USER MANUAL – XSI-PPS-1.2K – 2.5K XSI-PPS-2.5K Panel Model: XPV-330-34M SOLAR INPUT DATA - XSI-PPS DATOS DEL PANEL Max. Power Range (Vdc) Potencia I Max (Vdc) (Vdc) (Vdc) (Adc) x MPPT 3.000 40,3 9,71 ARREGLO DE PANELES SOLARES Imp x Total Total Voc Total...
Page 33
USER MANUAL – XSI-PPS-1.2K – 2.5K ANNEX 2. FAULT & WARNING CODES / TROUBLESHOOTING IMPORTANT: Alarm and Fault States are represented on the LCD screen through numerical codes, accompanied by the Alarm or Fault icon, ▪ as appropriate. ALARMS: Alarms are typically displayed intermittently on the screen, accompanied by an intermittent audible alarm. The ▪...
USER MANUAL – XSI-PPS-1.2K – 2.5K AVAILABLE FAULT CODES Error codes (Failures) are displayed on the screen, accompanied by a steady audible alarm and the ERROR icon on the screen. The following table shows the available error codes for this equipment FAULT FAULT FAULT DESCRIPTION...
USER MANUAL – XSI-PPS-1.2K – 2.5K TROUBLESHOOTING Fault Description Cause Solution Fault Code: [01] Fan failure Contact technical support to replace the fan. Continuous alarm 1. Check if the units ventilation is blocked or if the ambient Fault Code: [02] Component Overheating temperature is too high.
Page 36
USER MANUAL – XSI-PPS-1.2K – 2.5K Red LED of the Wireless Charger Possible fault in the wireless Restart the unit. blinking intermittently. charger. If the issue persists, contact technical support. IMPORTANT: In case of a severe fault or if a burning smell is detected, immediately turn off the inverter, cut power to the input lines, and ensure that the LCD screen and LEDs turn off.
USER MANUAL – XSI-PPS-1.2K – 2.5K ANNEX 3. WIFI SETTING AND MONITORING VIA APP – i.SOLAR WiFi module in our solar devices (both inverters and power stations) allows the user to have remote control and monitoring through the i.Solar App, available for both IOS and Android devices. All data logs and parameters are stored in the cloud. i.Solar is an application specifically designed for smartphones, so while it can be run on tablets, there may be some changes in style and appearance, although the functions will work the same.
Page 38
USER MANUAL – XSI-PPS-1.2K – 2.5K Once communication with the inverter's WiFi network is established, launch the i.Solar application on your phone, and the login screen will appear, as shown in the image on the right. There, click on the "Network Config" button to enter the network configuration that allows the inverter to communicate with the Data server.
Page 39
USER MANUAL – XSI-PPS-1.2K – 2.5K Once the data has been transmitted to the XSI-PPS, a pop-up window will appear confirming the success of the operation and offering the option to test the WiFi module's communication with the internet via the network just configured.
Page 40
USER MANUAL – XSI-PPS-1.2K – 2.5K Once in the registration area: Enter your Username Password Re-enter your password for confirmation Click the "Register" button to save the account settings. The next time you need to access the App, you will only need to enter the account details you created and click the "Login"...
Page 41
USER MANUAL – XSI-PPS-1.2K – 2.5K HOME PAGE The Home page of i.Solar is shown on the right, where the electricity generation graph can be seen. By tapping the Day, Month, Year, or Total tabs, you can view the electricity generation by hours, by days, by months, or the total for the current year, respectively.
Page 42
USER MANUAL – XSI-PPS-1.2K – 2.5K Ingresando el Número de Serie de un XSI-PPS y presionando el botón “Add” se puede añadir el equipo a la Aplicación, como se muestra en la pantalla de la derecha. Los equipos recién agregados pueden mostrar el nombre “unnamed”...
USER MANUAL – XSI-PPS-1.2K – 2.5K On the screen to the right, the icon to use for deleting any of the inverters from the App is indicated. DEVICE MANAGEMENT By selecting any of the devices listed on the home page, its specific screen will be displayed, showing its real-time data. The data includes battery information (Temperature, SOC, Capacity, Voltages, etc.), Input (Solar and AC), and Output information.
Page 44
USER MANUAL – XSI-PPS-1.2K – 2.5K The images in the center and on the right show the configuration parameters screen. Once the desired changes have been made, you must press the "SAVE" icon to send and store them. If the process is successful, the message "Send Succeeded"...
Page 45
USER MANUAL – XSI-PPS-1.2K – 2.5K CONFIGURACION From the home screen (Home), you can access the configuration screens for the operational parameters of i.Solar App. The image on the right shows the Configuration tab on the Home screen. The far-right image shows the available configuration options: Change Password Delete Account...
Page 46
USER MANUAL – XSI-PPS-1.2K – 2.5K Delete Account This option allows you to delete the account currently in use on the App. When pressing the Delete Account button, a pop-up window will appear asking for confirmation to permanently delete the account. Select OK to delete the account or Cancel to stop the action.
USER MANUAL – XSI-PPS-1.2K – 2.5K SUPPORT & WARRANTY XMART XSI inverters feature a powerful internal battery charging system, powered by both the AC input and the solar input. Both inputs can charge the batteries simultaneously or separately, depending on how the inverter is configured. Support: If a failure or problem is detected please check troubleshooting section in user manual.