asis WebENTRA R500 Series User Manual

Se mobile reader
Hide thumbs Also See for WebENTRA R500 Series:

Advertisement

Quick Links

WebENTRA R500 Series SE Mobile Reader
User Manual
Document History
Description
st
Aug 2022 1
Release
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to operate this equipment. (Example - use
only shielded interface cables when connecting to computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference
received, including interference that may cause undesired operation.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WebENTRA R500 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for asis WebENTRA R500 Series

  • Page 1 WebENTRA R500 Series SE Mobile Reader User Manual Document History Description Aug 2022 1 Release Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 2: Limited Warranty

    Information in this manual is subjected to change without further notice. ASIS Technologies make all efforts to ensure this Manual is up to date and corresponds to the product being shipped. However, ASIS Technologies assumes no responsibility for any errors that may occur in this manual.
  • Page 3: Table Of Contents

    Contents Packaging List ........................5 R500 Series BLE NFC Reader Overview ................ 5 Reader Wiring and Color Code ..................6 DIP Switch Setting ......................6 Installation and Mounting Instruction ................7 Reader Connectivity to Controller ..................9 Operation Guide ......................10 Reader Transaction Indicator (R500) ................
  • Page 4: Packaging List

    UID card to double size UID card. Card ID data can be output via industry standard Wiegand, OSDP or ASIS Proprietary ADNET. Three models are available to cater for various modes of security and operation needs.
  • Page 5: Reader Wiring And Color Code

    3. Reader Wiring and Color Code Table 2 show Cable color of the reader and it function description Terminal Point Label Description Cable Color Dev+ RS485+ Blue Dev- RS485- Grey +12VDC DC Ground Black Wiegand Data 0 White Wiegand Data 1 Green Red LED Brown...
  • Page 6: Installation And Mounting Instruction

    56bit 64bit 80bit 168bit(ASIS) Table 5 Wiegand bit format DIP Switch setting Note: Since the Contactless Smartcard CSN is 32 bit, it can be up to 10 digits decimal when converted. This is the solution to truncate the CSN and provide a result that once converted, it only give maximum of 8-digit decimal.
  • Page 7 d) Mount the back cover on the wall using 2 screws. e) Connect the external (site) cable to the terminal block on the reader according to the wiring code below. Double-check the wiring connection. Replace the snap on cover and tighten it with the screw provided. g) Switch on the power to test the reader and observe.
  • Page 8: Reader Connectivity To Controller

    6. Reader Connectivity to Controller RS485 Black Blue Grey Reader Controller Ethernet PoE Switch Cat6 Cable Cat6 Cable Reader Controller...
  • Page 9: Operation Guide

    Operation Guide The R500 Series BLE NFC Reader can be used with NFC and BLE via following operations; a) NFC The NFC mode supports highly secure and intentional operation with the use of contactless smartcards and mobile phones. Typical range of operation is 5cm. Access using NFC card without PIN Bring the card in parallel to the R500 reader for a maximum read range.
  • Page 10: Radio Frequency Interference

    3 x 4 Keys (R51XK) Communication Interface RS485 or Wiegand (selectable) Wiegand Interface Output 26, 32, 37, 40, 56, 80, 168(ASIS) bits format and 8-digit 32, 37, 40 bits Bit Format format Support Card Type MIFARE ( ISO 14443-A, ISO 14443-B)

Table of Contents