Awenta KWS Operating Manual

Air exhaust fan

Advertisement

Quick Links

OPERATING MANUAL AIR EXHAUST FAN
KWS · KWT
IMPORTANT NOTICE
Please read the Operating Manual carefully before attempting to install or service the air exhaust fan! AWENTA shall not be liable for any
damage resulting from incorrect operation, non-intended use or unauthorized repair or modifications of the product.
The Operating Manual and the installation instructions contained in it are an essential part of the product equipment. The Operating
Manual speci es important technical information and instructions for the operating safety of the air exhaust fan. Carefully read the
installation instructions in the Operating Manual. Keep the Operating Manual available for future reference. A copy of the Operating
Manual can be downloaded from www.awenta.pl
Warnings
The following safety symbols show important safety information. Follow all safety regulations and the safety symbols shown in the
Operating Manual to avoid injury and hazards.
Danger!
Electrocution hazard: high voltage!
Caution – rotating elements!
Safety precautions:
This product can be used by children at least 8 years old, by people with impaired physical
EN
11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KWS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Awenta KWS

  • Page 1 IMPORTANT NOTICE Please read the Operating Manual carefully before attempting to install or service the air exhaust fan! AWENTA shall not be liable for any damage resulting from incorrect operation, non-intended use or unauthorized repair or modifications of the product.
  • Page 2 and/or mental abilities, and by people without any experience in or understanding of the operation of the product, if supervised or instructed by a competent adult in the safe use of the product so that they understand the relevant operating risks. This product is not a toy and children should not play with it.
  • Page 3: Application And Operating Conditions

    • Never attempt to modify or alter the air exhaust fan without authorization. • Before installing the air exhaust fan, verify the load bearing capacity of the installation substructure. Improper installation fastening may result in damage or failure of the air exhaust fan and hazards to the people nearby. The air exhaust fan can be hazardous when operated against its intended use or installed by unqualified personnel.
  • Page 4: Transport And Storage

    • The devices equipped with ball bearings are designed for a minimum operating life of 30,000 hours in S1 duty cycle at the maximum power output and the maximum ambient temperature. • The control system must prevent extremely frequent power cycling. Transport and storage •...
  • Page 5 exceeds the start threshold of the humidity sensor. Next, the fan will stop when the air humidity level is reduced below the stop threshold, plus the stop delay time set with the stop delay timer. If connected as shown in Fig.3, the fan can also be started with its standard light sensor or operating the separate on/o switch. When the indoor light is o or the on/o switch is turned o , the fan will stop after the stop delay time set with the potentiometer if the humidity level in the room is below the level preset on the potentiometer.
  • Page 6: Installation Process

    The stop delay time is counted down from the time the indoor lights are switched o or from the time the separate switch to which the device is connected is turned o . Movement (part index letter 'M'). Connect the air exhaust fan with the microwave motion sensor and timer as shown in the electrical wiring diagram, see Fig. 4. The fan starts when the motion sensor detects someone in the room.
  • Page 7: First Start

    check that there is enough clearance for the opening motion of the check damper closure on the fan outlet end (the check damper is sold separately); It is recommended to connect the fan to the duct system using a exible pipe connection! •...
  • Page 8: Electrical Connections

    touch due to their installation conditions (e.g. in line with the air ductwork), no direct touch guard is required if the installation conditions provide an equivalent level of safety. Note that the fan user is liable for compliance with current safety standards and may be held liable for accidental injury or death caused by failure to provide the required safety equipment.
  • Page 9: Warranty Terms And Conditions

    Cleaning Electrocution hazard by damaged wiring insulation! Before attempting to clean the vfan, isolate it from the mains voltage with the circuit breaker. Secure the circuit breaker against inadvertent operation! • Clean the front panel and the visible parts of the housing with a damp cloth. •...
  • Page 10 The product is made from recyclable materials and components. The product user is required to return the product which has become WEEE to a WEEE collection unit. The operators of WEEE collection units, including local WEEE locations, product resellers and other WEEE collection locations managed by local authorities form a proper waste disposal system.
  • Page 11 Rys. 1 Fig. 1 Изобр. 1 Obr. 1 Rys. 2 Fig. 2 Изобр. 2 Obr. 2 Rys. 3 Fig. 3 Изобр. 3 Obr. 3 Rys. 4 Rys. 5 SPEED TIME Fig. 4 Fig. 5 Изобр. 4 Изобр. 5 Obr. 4 LED1 LED2 LED3 LED4 Obr.
  • Page 12 INDEX / Ø are achieved with people moving towards the fan. / KWS/KWT 100 . / Upozornění: Nejlépe jsou detekované osoby, které se pohybují KWS/KWT 125 ve směru ventilátoru. / Pozor: Najlepšie sú detegované osoby, ktoré sa pohybuje smerom k ventilátoru.

This manual is also suitable for:

Kwt

Table of Contents