We want you to know that if you ever have a concern or problem with a PESA product, we have a team of engineers, technicians and customer service professionals available 24/7/365 to help resolve the issue.
Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 IST OF IGURES 2-1. RCP-MP32D C ) ................2-1 IGURE ONTROL ANEL RONT 2-2. RCP-MP32D C ) ................2-1 IGURE ONTROL ANEL 3-1. R ..................3-2 IGURE EMOTE ONTROL ANEL NSTALLATION 3-2. DIP S ......................3-2...
OCUMENTATION AND AFETY VERVIEW This manual provides instructions for the installation and operation of the RCP-MP32D Remote Control Panel built by PESA. It is the responsibility of all personnel involved in the installation, operation, and maintenance of the equipment to know all the applicable safety regulations for the areas they will be working in. Under no circumstances should any person perform any procedure or sequence in this manual if the procedural sequence will directly conflict with local Safe Practices.
Data keys on the front of RCP-MP32D Control Panel are divided into four pages of 32 keys each. Page one provides access to data keys 1-32, Page two provides access to data keys 33-64, page three provides access data keys 65-96, and page four provides access to data keys 97-128.
Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 PECIFICATIONS GENERAL Mounting Push-buttons Illuminated and Legend-able INPUT Communications Port RS485 POWER Voltage Requirements +7.5VDC @ 800mA MECHANICAL Physical Dimensions 19"W X 3"D X 1.75"H 482.6mm X 76.2mm X 24.45mm...
OCATION AND OUNTING The RCP-MP32D Control Panel has been designed to fit in a standard E.I.A. 19" equipment rack and occupy one rack unit of space (1.75"). An installation area should be selected where the ambient temperature will not exceed 40°C, and where air can circulate freely. The control panel should be mounted in an area convenient to control and power connections.
Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 Figure 3-1. Remote Control Panel Installation OLLING DDRESS For the system controller to identify a particular control panel, a specific device number or polling address must be assigned to each panel. Sequential binary numbers (1 through 1023) are used for this purpose.
Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 ONTROL ANEL ONTROLLER NTERCONNECTION Each control panel has a single 3-pin MTA connector located on its rear panel which is utilized for system communications to and from the controller. Control panels are daisy-chained to a communications port on the rear panel of the system controller or to a communications port on the rear panel of the routing switcher containing the system controller.
Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 IRING ONTROL ANEL ONNECTOR Should an additional panel be added to your system, it will be necessary to wire the connector using shielded twisted pair cable and a 3-pin MTA connector using the following instructions. See Figure 3-4.
OWER ONNECTIONS Power for the RCP-MP32D Control Panel is supplied an external 7.5 VDC, 800 mA power supply. Remove the power supply from the box it was shipped in and check to insure that no damage has occurred in shipping. Verify that the power supply is rated for the proper AC voltage (i.e. 115 VAC or 230 VAC) before connection to the AC line voltage.
WITCH SSEMBLY Legends on the front panel pushbuttons of the RCP-MP32D Control Panel may be changed as needed. If it becomes necessary, due to configurations changes, to change the switch labels (legends) take the following steps to disassemble the switch cover to gain access to the switch legend while referring to...
Page 14
Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 Once the legend and the legend retaining are inserted into the clear cap, align the right and left sides (the sides with the tabs) with the right and left sides of the switch base.
Win3500 Control System Manual or the PERC 2000 Technical Manual for configuration instructions. All RCP-MP32D Control Panels in a routing switcher system are custom configured at the factory prior to shipment. The information needed to configure the control panels comes from the System Design Guide filled out by the customer.
YPES RCP-MP32D control panels are equipped with 40 pushbuttons configured with 32 data keys on the left, 4 page keys on the top right, 3 permanent data keys on the bottom right, and the lock/protect function key.
Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 • Level Key – The level keys activate or deactivate the level of control associated with the key. (Active levels cause their associated level button to be lit.) One or more level keys can be active at any one time.
Page 18
Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 OURCE ALLY REAKAWAY TATUS LED Illuminated Solid (not blinking) The current status matches the source assigned to the data key for all the selected levels LED Blinking The current status matches the source assigned to the data key for the highest priority level selected (level 1 is the highest priority level) but does not match for at least one other selected levels.
Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 Chapter 5 Panel Configuration The following are the fields that need to be configured in the System Controller Configuration Editor. A more complete description of these fields is included in the Technical Manual for the System Controller.
Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 EVELS OF ONTROL List of levels to be controlled by the panel. Any level not assigned in the Levels of Control List will not be accessible or affected by panel operations.