PESA RCP-MP32D Technical Manual

PESA RCP-MP32D Technical Manual

Remote control panel with status display

Advertisement

Quick Links

T
M
ECHNICAL
ANUAL
RCP-MP32D
R
C
P
EMOTE
ONTROL
ANEL
W
S
D
ITH
TATUS
ISPLAY
Publication: 81-9059-0624-0, Rev. B
February, 2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RCP-MP32D and is the answer not in the manual?

Questions and answers

Summary of Contents for PESA RCP-MP32D

  • Page 1 ECHNICAL ANUAL RCP-MP32D EMOTE ONTROL ANEL TATUS ISPLAY Publication: 81-9059-0624-0, Rev. B February, 2012...
  • Page 2 We want you to know that if you ever have a concern or problem with a PESA product, we have a team of engineers, technicians and customer service professionals available 24/7/365 to help resolve the issue.
  • Page 3: Table Of Contents

    Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 ABLE OF ONTENTS CHAPTER 1 ABOUT THIS MANUAL ..................1-1 ................ 1-1 OCUMENTATION AND AFETY VERVIEW ................... 1-1 ARNINGS AUTIONS OTES CHAPTER 2 INTRODUCTION ....................2-1 ..................... 2-1 ENERAL ESCRIPTION ........................ 2-2...
  • Page 4: List Of Figures

    Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 IST OF IGURES 2-1. RCP-MP32D C ) ................2-1 IGURE ONTROL ANEL RONT 2-2. RCP-MP32D C ) ................2-1 IGURE ONTROL ANEL 3-1. R ..................3-2 IGURE EMOTE ONTROL ANEL NSTALLATION 3-2. DIP S ......................3-2...
  • Page 5: Chapter 1 About This Manual

    OCUMENTATION AND AFETY VERVIEW This manual provides instructions for the installation and operation of the RCP-MP32D Remote Control Panel built by PESA. It is the responsibility of all personnel involved in the installation, operation, and maintenance of the equipment to know all the applicable safety regulations for the areas they will be working in. Under no circumstances should any person perform any procedure or sequence in this manual if the procedural sequence will directly conflict with local Safe Practices.
  • Page 6: Chapter 2 Introduction

    Data keys on the front of RCP-MP32D Control Panel are divided into four pages of 32 keys each. Page one provides access to data keys 1-32, Page two provides access to data keys 33-64, page three provides access data keys 65-96, and page four provides access to data keys 97-128.
  • Page 7: Specifications

    Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 PECIFICATIONS GENERAL Mounting Push-buttons Illuminated and Legend-able INPUT Communications Port RS485 POWER Voltage Requirements +7.5VDC @ 800mA MECHANICAL Physical Dimensions 19"W X 3"D X 1.75"H 482.6mm X 76.2mm X 24.45mm...
  • Page 8: Chapter 3 Installation

    OCATION AND OUNTING The RCP-MP32D Control Panel has been designed to fit in a standard E.I.A. 19" equipment rack and occupy one rack unit of space (1.75"). An installation area should be selected where the ambient temperature will not exceed 40°C, and where air can circulate freely. The control panel should be mounted in an area convenient to control and power connections.
  • Page 9: Polling Address

    Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 Figure 3-1. Remote Control Panel Installation OLLING DDRESS For the system controller to identify a particular control panel, a specific device number or polling address must be assigned to each panel. Sequential binary numbers (1 through 1023) are used for this purpose.
  • Page 10: Control Panel /Controller Interconnection

    Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 ONTROL ANEL ONTROLLER NTERCONNECTION Each control panel has a single 3-pin MTA connector located on its rear panel which is utilized for system communications to and from the controller. Control panels are daisy-chained to a communications port on the rear panel of the system controller or to a communications port on the rear panel of the routing switcher containing the system controller.
  • Page 11: Wiring The Control Panel Connector

    Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 IRING ONTROL ANEL ONNECTOR Should an additional panel be added to your system, it will be necessary to wire the connector using shielded twisted pair cable and a 3-pin MTA connector using the following instructions. See Figure 3-4.
  • Page 12: Terminating Cable Runs

    OWER ONNECTIONS Power for the RCP-MP32D Control Panel is supplied an external 7.5 VDC, 800 mA power supply. Remove the power supply from the box it was shipped in and check to insure that no damage has occurred in shipping. Verify that the power supply is rated for the proper AC voltage (i.e. 115 VAC or 230 VAC) before connection to the AC line voltage.
  • Page 13: Switch Cap Assembly

    WITCH SSEMBLY Legends on the front panel pushbuttons of the RCP-MP32D Control Panel may be changed as needed. If it becomes necessary, due to configurations changes, to change the switch labels (legends) take the following steps to disassemble the switch cover to gain access to the switch legend while referring to...
  • Page 14 Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 Once the legend and the legend retaining are inserted into the clear cap, align the right and left sides (the sides with the tabs) with the right and left sides of the switch base.
  • Page 15: Chapter 4 Operation

    Win3500 Control System Manual or the PERC 2000 Technical Manual for configuration instructions. All RCP-MP32D Control Panels in a routing switcher system are custom configured at the factory prior to shipment. The information needed to configure the control panels comes from the System Design Guide filled out by the customer.
  • Page 16: Display

    YPES RCP-MP32D control panels are equipped with 40 pushbuttons configured with 32 data keys on the left, 4 page keys on the top right, 3 permanent data keys on the bottom right, and the lock/protect function key.
  • Page 17: Data Key Tally

    Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 • Level Key – The level keys activate or deactivate the level of control associated with the key. (Active levels cause their associated level button to be lit.) One or more level keys can be active at any one time.
  • Page 18 Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 OURCE ALLY REAKAWAY TATUS LED Illuminated Solid (not blinking) The current status matches the source assigned to the data key for all the selected levels LED Blinking The current status matches the source assigned to the data key for the highest priority level selected (level 1 is the highest priority level) but does not match for at least one other selected levels.
  • Page 19: Chapter 5 Panel Configuration

    Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 Chapter 5 Panel Configuration The following are the fields that need to be configured in the System Controller Configuration Editor. A more complete description of these fields is included in the Technical Manual for the System Controller.
  • Page 20: Levels Of Control List

    Remote Control Panel – RCP-MP32D Publication 81-9059-0624-0, Rev. B February 2012 EVELS OF ONTROL List of levels to be controlled by the panel. Any level not assigned in the Levels of Control List will not be accessible or affected by panel operations.

Table of Contents