Hinen PS1800 User Manual

Hinen PS1800 User Manual

1800w power station portable

Advertisement

Quick Links

FCC Statement
This device complies with Part �� of the FCC Rules. Operation is subject to the following two conditions:
(�)This device may not cause harmful interference.
(�)This device must accept any interference received, including interference that may cause undesired operation.
�. Changes or modifications not expressly approved by the party responsible for compliance could void the user' s authority to operate the equipment.
Note:This equipment has been tested and found to comply with the limits for a class B digital device,pursuant to Part �� of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequence energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipmemt does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment and receiver.
· Connect the equipment into an autlet on a circuit different from that to which the receiver is connected.
· Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement, This equipment should be installed and operated with a minumum distance of ��
cm between the radiator and your body.
ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada' s licence-exempt
RSS(s). Operation is subject to the following two conditions:
This device may not cause interference.
This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment should be installed and operated with a minimum distance of �� cm between the radiator and your body.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables auxappareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes :
(�)l'appareil ne doit pas produire de brouillage, et (�) l'utilisateur de l'appareil doit accepter toutbrouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre lefonctionnement. Cet équipement doit être installé et utilisé avec une distance minimale de �� cm entre le radiateur et
votre corps.
����W Power Station
portable
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PS1800 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hinen PS1800

  • Page 1 ����W Power Station portable FCC Statement This device complies with Part �� of the FCC Rules. Operation is subject to the following two conditions: (�)This device may not cause harmful interference. (�)This device must accept any interference received, including interference that may cause undesired operation. �.
  • Page 2: Table Of Contents

    �. Parameters General Net weight ≈��.�kg (≈��.�lbs) Content Dimension ���*���*���mm (��*��.�*��.�in) Battery capacity ����Wh, ��.�V , ��Ah Wi-Fi supported Output (EU/FR/AU/ZA) �. Parameters � AC socket x� (Inverter mode) pure sine-wave, total ����W (peak ����W), ���-���V~, � �Hz/��Hz, ��A ���-���V~, ��Hz/��Hz, ����W Max., ��A Max. �.
  • Page 3: Safety Guidelines

    Battery ��. Power supplies will inevitably generate electromagnetic fields when it is in use, which might affect the implantable medical device or normal operation of personal medical device, such as pacemaker devices, cochlear implants, hearing AIDS, defibrillators, etc. If any Cell Type lithium iron phosphate battery (LiFePO of these medical devices are used, please consult the manufacturer about the restrictions on the use to ensure that power station is...
  • Page 4: Lcd Screen

    �.� Use Ventilation opening Note: Long press the ON/OFF button to turn off the machine and clear the fault information. Overload protection switch AC input socket Solar / car charge input Quick charge / slow charge switch Short press to turn on Long press to turn off...
  • Page 5: Ac Charging

    Note: When no AC input, long press the above AC output button, you can switch the AC off-grid output frequency ( ), long press �s to switch, the AC output icon will flash � times after successful LED lights switching. ·...
  • Page 6: Pv Charging

    You can control and view information and data about this product by App. Software download, search for [HINEN] in the Google App Store or Apple App Store, download the software, register and open Charge the power station by solar panel.
  • Page 7: Eps Function

    �. Error messages & solutions �.� EPS function This product supports the EPS (emergency backup power) function. You connect the power grid and the AC input port of this product through the AC charging cable; Bypass mode (AC power comes from the grid, not the battery); when the grid suddenly loses Fault Description Icon Solution...
  • Page 8: Maintenance

    �. What's in the box Icon Fault Description Solution Turn on and off, Error code always on Fan stop contact after sales if still not fixed. Discharge soft start fault Error code always on Auto recover after fault is cleared. Error code always on Charge soft start fault Turn on and off,...

This manual is also suitable for:

Ps3000

Table of Contents