INTRODUCTION The “Wifipool Twin” is used to monitor and control pH, and Redox (chlorine), of your swimming pool. pH and redox (chlorine) are measured continuously. If pH is too high, or chlorine levels too low, it will automatically pump liquid pH- or Chlorine in the swimming pool. With three versatile variants available : the standalone option for DIY installation, the pre-mounted panel option, or the box-mounted version.
SAFETY WARNINGS AND INSTRUCTIONS General • Installation personnel should read this manual carefully before proceeding with installation. In case of incorrect use, contact your provider. • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental abilities, or lack of experience and knowledge, except under the supervision or instruction of a responsible person regarding its safe use.
Page 5
• To ensure proper operation of peristaltic pumps, check the pumps weekly for leaks. In case of leaks, please refer to the complete manual of your installation on www.beniferro.eu • Ensure that the measuring probes remain consistently moist during transportation, especially when being transported for maintenance or repair work at the supplier's facility.
The dosing capacity can be regulated with the “duty cycle” down to 1 % of the normal dosing velocity. Therefore , the Pool size has a wide capacity : from 2m³ to 150 m³. On demand, Beniferro can use dosing pumps with higher dosing capacity (up to 1000 m³ swimming pools)
PAIRING AND SETUP INSTRUCTIONS Carry out pairing and setup before physical installation, indoors in a environment with a ethernet connection and a strong wifi signal of the future swimming pool wifi network Setting up the wifi connections • Install Wifipool app Install the Wifipool app on your telephone.
Page 8
Here are some recommendations for expanding your automation Create a scheduler-snippet to define the time during which the pH pump and RX pump can run. Make sure the automation starts 15 min after start-up of flow, to make sure the pH and Redox probes are in equilibrium before starting the chemical treatment.
Page 9
PFFS: - pH > 7.6 and flow switch detects flow: This will enable the pH pump. - RX < 700, pH ≤ 7.6, and flow switch detects flow: This will enable the RX pump. 2 automation via scanning For additional information regarding automation features and setup via scanning, please refer to the Wifipool and Simple Device manual.
Page 10
The pH- pump will work if: pH>7,6 AND Flow = true pH drum is not empty (only if level detection is present) The RX pump will work if: pH<=7,6 AND RX<700 Flow = true 3 automation via manual entry Enter the conditions described above, manually into your Wifipool app. Consult the Wifipool app and simple device manual for details.
Page 11
1. To add a manual entry, simply tap the plus icon and select "Manual Automation Entry." This will initiate a new procedure. 2. Ensure to rename the procedure to a more fitting title. 3. You can incorporate conditions by using the "Add Condition" icon. 4.
INSTALLATION INSTRUCTIONS General The factory supplies the water treatment unit electrically connected and, in some case, already mounted on a plate or in a box. Modification to the unit has to be made by trained personnel, knowledgeable about swimming pool technology and electrical systems. The attention points below must be respected.
Page 13
If you purchased a Pool Twin liquid chlorine, in parts, or if modifications are made to the unit: Install the different elements in the following order: 1. pH and RX measurement 2. pH and RX adjustment Follow the installation scheme just as the picture above Make sure following requirements are met: •...
Page 14
If you do not have a flow switch on the unit, adjust the electrical connections so that The • chlorine and acid pumps cannot work if the filter pump does not work. The electrical 230V feed to the wifipool control box must loose power as soon as the filter pump switches off.
OPERATING INSTRUCTIONS General instructions After pairing and physical installation of the unit, we are ready to start calibrate, leak-test and start-up the unit. • Before using the equipment, pH and RX probes have to be calibrated • The measuring probes must always be kept moist during transport. A small box containing fluid is provided for this purpose, ensuring the integrity of the product.
Page 16
Unpair Calibrate module Rx Rename Calibrate module pH Calibrate • The calibration process will take +- 3-4 minute per probe, and the app will indicate whether the calibration was successful or not. Leaktesting and leak managment Insert the pH and RX probes after calibration and put water pressure and flow through the unit.
Page 17
Start up Start up the filterpump, and switch on the power to the water treatment unit. As soon as flow is detected, the unit will start up. Consider starting up the water treatment 15 min later than the filter pump by using a scheduler. pH and RX setting We recommend to set the pH at 7.6.
Page 18
Deviation of the pH measurement compared with another method. When working with probes, one must accept the following as true: - In principle, a calibrated probe measures correctly, more correctly than a color method. - A probe that calibrates itself works - The color method works correctly, only if the alkalinity of the water is correct - A difference of 0.2 between two methods is normal, a difference of 0.5 is not acceptable.
Page 19
Deviation of the Redox measurement compared with another method. A deviating RX value is not so bad, as long as the probe is sensitive to changes and the redox increases when more chlorine is added to the pool. You can test this by mixing 5 drops of liquid chlorine in a bucket of water and measuring the redox before and after adding the chlorine.
Page 20
Reducing pH dosing speed and Chlorine generation intensity for small pools or SPA The pH / chlorine dosing speed can be reduced by adjusting the Duty cycle in the pH and RX automation sheet. In the example where the duty Cycle is 33% per 60 seconds, the pH pump will dose 33% of 60 seconds = 20 seconds each minute.
MAINTENANCE INSTRUCTIONS • Maintenance should be carried out at the recommended time and frequency as stated in the manual. Maintenance of the water treatment Maintenance has to be carried out by a person knowledgeable off swimming pool technology. Make sure to take the necessary safety precautions before starting the maintenance such as: •...
Maintenance of the Chlorine injection nipple Anti calc The chlorine injection nipple can leak due to blockage by saling / Calcium carbonate cristals coming from the chlorine (blockage before the one-way rubber in the chlorine injector), or from high water hardness (Calcium content) of the swimming pool water. This can be avoided by adding anti-scalinig to the chlorine.
The accumulation of scale within the injection nipple obstructs its function, potentially disrupting the flow. This obstruction can result in various undesirable outcomes: Decreased or halted chlorine flow Leakage from the injection nipple itself Swelling and leakage of peristaltic tubes Such issues not only jeopardize operational efficiency but also present safety hazards.
Page 24
Method 2 : Chemical descaling Step 1: Flush the chlorine injection circuit with a minimum of 1.5 liters of water. • Unscrew the injection nipple from the measurement and injection tube, ensuring that you can catch the chlorine/water mixture that you are about to pump through the chlorine injection system.
Page 25
Step 3: Flush the chlorine injection circuit with a minimum of 1.5 liters of water. This step is a repetition of Step 1 to ensure no residual acid remains in the system. Remember: Liquid chlorine and acid react to form poisonous chlorine gas. After completing these steps, screw the injection nipple back into position, pressure test, and restart chlorine addition.
WINTERIZING AND SPRING START-UP INSTRUCTIONS Winterizing the system Winterize the units containing electronics, unit in a dry and warm (15 – 25 ° C) environment. Winterize the pH and RX probes in a special winterizing solution for probes (which is a KCl-water mixture).
TROUBLESHOOTING Troubleshooting Wi-Fi / app related problems For Wi-Fi equipment, it is possible to share the app with your supplier or the manufacturer. This is explained in the Problem-solving section of the Wifipool app and simple device manual. Setting up a Teams meeting via your telephone and sharing the screen will also allow your supplier / manufacturer to see your telephone screen.
3. Renew the pills/liquids of your measurement tool and remeasure the pH with your color method. If doubt remains : 4. Buy a new calibration solution and measure pH with probe. If doubt remains 5. Buy a certified pH 7.4 solution and measure pH with a probe. If the pH of the probe is between 7.2 and 7.6 accept the probe.
Page 29
PROBLEM CAUSE SOLUTION Acid pump does not dispense No electrical power present Verify electrical power Startup acid pump via manual control. Acid pump does not dispense Switch under the dosing pump is Set switch to "1" set to "O" Settings of pH control are wrong : Verify settings pH+ while pH- is dosed (or vice versa)
Page 30
Injection nozzle is clogged Replace injection nozzle ZWMX2220 Liquid (acid) in dosing Santoprene or Viton tube leak Verify if dosing nipple is clogged, compartment of acid pump and replace dosing hose. Ensure dosing tube is greased regularly Dosing tube in pH forms a Supply of acid in injection nipple Immediately stop dispensing acid bladder...
Once linked, he/she adds you as a user and promotes you to owners. Also let us know (info@beniferro.eu) what phone you have and what IOS or Android version it has so we can customize the app.
Need help?
Do you have a question about the Wifipool Twin and is the answer not in the manual?
Questions and answers