Galaxy Equipment 177UCCF5 User Manual

Ultra cold commerical chest freezers

Advertisement

User Manual
Ultra Cold
Commerical Chest Freezers
01/24
177UCCF5, 177UCCF8
Please read the manual thoroughly prior to equipment setup,
operation, and maintenance.
- 1 -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 177UCCF5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Galaxy Equipment 177UCCF5

  • Page 1 User Manual Ultra Cold Commerical Chest Freezers 01/24 177UCCF5, 177UCCF8 Please read the manual thoroughly prior to equipment setup, operation, and maintenance. - 1 -...
  • Page 2 User Manual Warning DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING. PELIGRO - RIESGO DE INCENDIO O EXPLOSION. REFRIGERANTE INFLAMABLE UTILIZADO. PARA SER REPARADO SOLAMENTE POR PERSONAL DE SERVICIO CALIFICADO. NO PINCHAR LA TUBERÍA REFRIGERANTE.
  • Page 3: Installation

    User Manual Installation This unit is intended for use in a temperature-controlled environment of less than 75°F and 60% relative humidity. Please read this manual thoroughly prior to equipment setup, operation, and maintenance. Important!!! Please Read Before Installation • If the unit has recently been transported on its side, please let the unit stand upright for a minimum of 24 hours before plugging it in.
  • Page 4 User Manual Electrical • Please ensure that the required voltage of the compressor is being supplied at all times. Low or high voltage can detrimentally affect the refrigeration unit. If the voltage is unstable, please choose a suitable automatic voltage regulator. •...
  • Page 5: Regular Maintenance

    User Manual Lock or Unlock Control Panel • The control panel default mode is unlocked. Press and hold the lock button for 3 seconds to lock or unlock the control panel manually. Defrosting the Unit • To ensure optimal performance, unit should be defrosted when the thickness of the ice on the cabinet wall reaches ¼".
  • Page 6: Safety Warning

    User Manual Safety / Warning Please pay close attention to the safety notices in this section. Disregarding these notices may lead to serious injury and/or damage to the unit. Attention • To minimize shock and fire hazards, be sure not to overload outlet. Please designate one outlet for your unit. •...
  • Page 7: Troubleshooting

    User Manual Troubleshooting Compressor Not Running Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker. Power cord unplugged. Plug in power cord. Thermostat set too warm. Set thermostat to a higher setting. Condensing Units Run For Long Periods of Time Excessive amount of warm product placed in cabinet.

This manual is also suitable for: