TABLE OF CONTENTS Safety Precautions ............1 Preparations and Set Up ..........1 Specifications ..............2 Keyboard and character prompt ........2 Operating Instructions ............3-5 Calibration ................ 6 Battery ................6 Maintain and service ............7...
SUMMARY The OPX-SS waterproof scale uses a high-precision resistor strain type sensor and the latest carefully designed and manufactured single-chip microcomputer, mainly for the need of waterproof weighing places, such as shops, fish markets, seafood and meat processing establishments. SAFETY PRECAUTIONS •...
SPECIFICATIONS UNIT\MODEL OPX-SS-3 OPX-SS-6 OPX-SS-15 OPX-SS-30 Capacity 3 kg (6.6 lb) 6 kg (13 lb) 15 kg (33 lb) 30 kg (66 lb) Resolution 0.1 g 0.2 g 0.5 g Dimensions 9.1” x 11” x 4.5” Pan Size 9.1” x 7.5”...
OPERATION INSTRUCTIONS 1. Preparation Adjust the base foot, watch the level, make the pan in horizontal. 2. Turn on or turn off 2.1 Turn on Press the [ON/ZERO] key with “ding” sound, it displays version No. and the battery voltage level and 9,8,7···1,0, the “ZERO” lamp lighting. Now the scale is in a working state.
Page 6
9. Set parameter Press [SET/0~9] key 3 seconds to set. rAngE (Range set) UnItS (Unit choose) A-oFF (Auto power off choose) FILt (Display mode set) ZEro (Auto zero set) bUZZEr (Buzzle set) d (Division choose) on-rA (Range of power on choose) d-dP (Single or dual display choose) 9.1 Set of upper and low limit: 9.1.1...
Page 7
9.2.2 Counting: When the display shows “pcs”, press [TARE]. The “pcs” lamp lighting. press [ON/ZERO], it shows count and return to 0. then put the sample and press [TARE]. Press [SET/0~9] to add 1 and press [TARE] to choose. After finishing it shows pcs and pcs lamp lighting.
10 Turn LED lighting On powering on, long time press [zero/on], it shows LC-,press [SET/0~9] to choose LU-1 or LU-2. LU-1 is saving mode (commend). Press [TARE] to confirm. EXTERNAL CALICATION • Push the adjust key to switch on, the switch is on the bottom of the scale, locked with a seal.
MAINTENANCE & SERVICE • Electronic scales are made up of sensitive precision components and microcomputer circuit. So correct use and maintenance is optimal for a long lasting unit. • Handle with care and avoid strong vibrations, shock or impact. • When using DC power, you should charge the battery in a timely manner to prevent the battery voltage from being too low lead to function improperly or not power on.
Need help?
Do you have a question about the OPX-SS and is the answer not in the manual?
Questions and answers