  • Page 2 Indu-Sol GmbH Blumenstraße 3 042626 Schmölln Phone: +49 (0)34491 / 580 0 +49 (0)34491 / 580-499 Fax: e-mail: info@indu-sol.com Web: https://www.indu-sol.com Our technical support team can be reached on +49 (0)34491 / 580 321, weekdays between 7:30 - 16:30 (CET).
  • Page 3: Revision Overview

    No claims can be derived from the information, illustrations and descriptions in this documentation. Any reproduction, further processing and translation of this document and extracts from it require the written authorisation of Indu-Sol GmbH. All rights under copyright law are expressly reserved by Indu-Sol GmbH. W A R N I N G This appliance may only be commissioned and operated by qualified personnel.
  • Page 4: Table Of Contents

    Web application Preparations System Login Web interface Start ASi Diag extension 3.5.1 Network overview 3.5.2 Participant overview Event list Settings 3.7.1 Participant names 3.7.2 Subscriber status 3.7.3 Triggers & alarms 3.7.4 Import/Export 3.7.5 Firmware ASi INspektor V2 - User manual...
  • Page 5 Table of contents System configuration 3.8.1 Device information 3.8.2 Network 3.8.3 password 3.8.4 e-mail 3.8.5 Date/Time 3.8.6 Access time 3.8.7 Backup and restore 3.8.8 Firmware update 3.8.9 Restart 3.8.10 System information Support ASi INspektor V2 - User manual...
  • Page 6: General Information

    1.2 Use of open source licences Indu-Sol offers the provision of source code of software that is licensed under the GPL or LGPL or other open source licences that require the distribution of source code. The individual licences used for the INBLOX system are listed on the website in the "Support and contact"...
  • Page 7: Scope Of Delivery

    Never open the housing of the appliance. Opening the housing immediately voids the warranty. In the event of a suspected defect, return the device to the supplier. There are no user-serviceable components in the devices. ASi INspektor V2 - User manual...
  • Page 8: Intended Use

    Always observe the technical specification of the device to ensure safe and optimal use. The device was developed for protective environments in accordance with IP20. Take suitable measures in the event of a different operating environment to ensure proper operation of the device ASi INspektor V2 - User manual...
  • Page 9: Connections And Status Displays On The Device

    LED orange - communication available Figure 1: INBLOX device connections - Ethernet head module 2.2 Device connections INBLOX - ASI Diag extension ASi connection ASi + ASi - Shield Figure 2: INBLOX device connections - ASi Diag extension ASi INspektor V2 - User manual...
  • Page 10: Installation

    Protect the INBLOX System from additional heat radiation and observe the authorised storage and operating temperature range. ASi INspektor V2 - User manual...
  • Page 11: Power Supply Connection

    M12 connection cable without interfering with ongoing system operation. The prerequisite is the use of the yellow ASi flat cable in the existing system, preferably directly on the master. No further settings are required on the ASi network. ASi INspektor V2 - User manual...
  • Page 12: Terminal Block

    If cable types other than the yellow ASi flat cable and terminal blocks are used in the system via the ASi network, the ASi Diag extension can also be clamped in directly. The ideal installation location is close to the master. No further settings are required on the ASi network. ASi INspektor V2 - User manual...
  • Page 13: Web Application

    It is your responsibility to document this password and protect it from unauthorised access. access. You can easily set your intended user addresses using the Indu-Sol ServiceTool. This is included in the scope of delivery or can be downloaded free of charge via the following link: https://sdx.indu-sol.com/s/qLZS8QgyqKNw9YL...
  • Page 14: System Login

    The cause of these events should be localised and rectified. Error: A critical fault has occurred in the network or in a device, resulting in a system failure. Urgent action is required to rectify the fault. ASi INspektor V2 - User manual...
  • Page 15: Start

    The selection in the menu bar allows you to call up the individual pages and make settings there. The menu items displayed are subdivided into further sub-items Information Message Menu bar window INBLOX system structure Figure 4: Start ASi INspektor V2 - User manual...
  • Page 16: Asi Diag Extension

    ASi faults occur permanently or occasionally. If faulty events occur within the monitoring period, this triggers the relevant fault trigger. This leads to entries in the alarm overview and the Event list. ASi INspektor V2 - User manual...
  • Page 17: Network Overview

    The meaning of the re statuses is explained in the legend. To increase clarity, you can select the display for the individual evaluation criteria. ASi INspektor V2 - User manual...
  • Page 18: Event List

    An entry in the Event list is made automatically when a trigger event is triggered and contains all important information, such as device address, error event and time. Figure 8: ASi Monitor - Event list ASi INspektor V2 - User manual...
  • Page 19: Settings

    An individual name and description can be assigned for each device under "Device name". This makes it possible, for example, to transfer and store the device type, the equipment identifier or the installation location from the electrical diagrams. All entries are then effective system-wide. ASi INspektor V2 - User manual...
  • Page 20: Subscriber Status

    By adding and editing further rules, the display of the participant statuses can be customised, e.g. due to special production conditions. In this case, the subscriber-specific settings overwrite the global values. This makes it possible to hide faulty events caused by normal system operation on a subscriber-specific basis. ASi INspektor V2 - User manual...
  • Page 21: Triggers & Alarms

    "Triggers and alarms". In the default setting of the device, all faulty events of any ASi subscriber automatically lead to an entry in the Event list. Figure 12: ASi Monitor - Triggers & Alarms ASi INspektor V2 - User manual...
  • Page 22: Import/Export

    These can be installed via a firmware update from this menu item. To do this, the new firmware file is selected via the button and uploaded or dragged directly into this field. After successful installation, it is necessary to restart the device using the "Restart" button. ASi INspektor V2 - User manual...
  • Page 23: System Configuration

    Web application Figure 14: ASi Monitor - Firmware If you would like to be informed automatically about the latest firmware changes, you can register for this via our download area (https://www.indu-sol.com/support/downloads/update-service) by selecting the relevant software. 3.8 System configuration The System configuration page displays the IP address settings, the time setting, access options to the device and general device information.
  • Page 24: Network

    DHCP server. As the device has now been assigned a new IP address, it can no longer be reached via the default IP. Please contact your network administrator or use an appropriate tool (Indu-Sol ServiceTool) to obtain the new IP address. Manual If your network does not have a DHCP server or you want to make the settings manually, deactivate the "Automatic (DHCP)"...
  • Page 25: E-Mail

    Time zone: Then select your valid time zone Manual In this setting, you have the option of manually entering the current date and time by clicking on the calendar icon. You can also select your valid time zone under "Time zone". ASi INspektor V2 - User manual...
  • Page 26: Access Time

    3.9 Support In the Support section you will find all relevant contact information for Indu-Sol Licence information The linked licence.txt file contains information about the "Open Source Software" used.
  • Page 27 Web application ASi INspektor V2 - User manual...