Summary of Contents for Winncare CAIRFLOW PM100A EVO

  • Page 1 WINNCARE France Technical Manual TM_CPED_EN - 1 -...
  • Page 2: Table Of Contents

    After 13 august 2005: Electrical and electronic equipment placed on the market ....- 8 - SPARE PARTS ............................- 9 - CAIRFLOW PM100A EVO DIGITAL compressor – Reference 826780 ........- 9 - CAIRFLOW PM100A EVO compressor – Reference 826776 ..........- 11 - CAIRFLOW PM100A EVO and PM100A EVO DIGITAL mattress ...........
  • Page 3: Alarms And Troubleshooting

    WINNCARE France ALARMS AND TROUBLESHOOTING No daily maintenance is required. This medical device should be serviced by a qualified and authorised technician. For advice on the type of fault, you can refer to the table below. Problem encountered Inspection Solution 1.
  • Page 4: Maintenance And Disinfection

    WINNCARE France MAINTENANCE AND DISINFECTION It is essential to disconnect the mains plug from the electrical cable connected to the compressor. The "mains" indicator must be off. Do not use a high-pressure jet to clean a CAIRFLOW compressor. Do not spray any liquid on the compressor to avoid any deterioration of the compressor by penetration of liquid inside the casing.
  • Page 5: Cleaning Of The Cover

    WINNCARE France LEANING OF THE COVER Check the integrity of the mattress cover (if it is damaged, it should be replaced with a new one). Take some disposable paper (cellulose wadding) and impregnate it with Surfanios. Scrub the entire surface of the mattress cover.
  • Page 6: Recommended Maintenance And Disinfection Flowchart

    WINNCARE France ECOMMENDED MAINTENANCE AND DISINFECTION FLOWCHART - 6 -...
  • Page 7: Preventive Maintenance

    WINNCARE France REVENTIVE MAINTENANCE ERIODICITY OF REVISIONS It is recommended to check the CAIRFLOW compressors at least once a year, in terms of flow rate and pressure. It is also recommended to check the pump body every year and the distributor every two years.
  • Page 8: Weee (Waste Electrical And Electronic Equipment)

    Except in the case of a replacement by an equivalent equipment or ensuring the same function. In this case, WINNCARE France applies the same procedure for the elimination of Waste Electrical and Electronic Equipment (WEEE) placed on the market after August 13, 2005.
  • Page 9: Spare Parts

    WINNCARE France SPARE PARTS CAIRFLOW PM100A EVO DIGITAL – R 826780 COMPRESSOR EFERENCE - 9 -...
  • Page 10 WINNCARE France List of references: References Designation SAVNEG1765 FRONT BOX SAVNEG1766 REAR CASE SAVNEG1553 PM100A EVO/DIGITAL MOUNTING HOOK SAVNEG1759 AIR MOTOR - PM100A EVO DIGITAL SAVNEG1760 DISTRIBUTOR MOTOR - PM100A EVO DIGITAL SAVNEG1761 ELECTRONIC BOARD - PM100A EVO DIGITAL SAVNEG1762...
  • Page 11: Cairflow Pm100A Evo Compressor - Reference 826776

    WINNCARE France CAIRFLOW PM100A EVO – R 826776 COMPRESSOR EFERENCE - 11 -...
  • Page 12 WINNCARE France List of references: References Designation SAVNEG1544 COMMON POWER CORD SAVNEG1553 PM100A EVO/DIGITAL MOUNTING HOOK SAVNEG1555 AIR FILTER PM100A EVO SAVNEG1616 AIR FILTER HOLDER PM100A EVO SAVNEG1576 REAR BOX PM100A EVO SAVNEG1572 AIR MOTOR 6LMN PM100A EVO SAVNEG1612 M/A SWITCH (PM100A/PM100AEVO)
  • Page 13: Cairflow Pm100A Evo And Pm100A Evo Digital Mattress

    WINNCARE France CAIRFLOW PM100A EVO PM100A EVO DIGITAL MATTRESS - 13 -...
  • Page 14 WINNCARE France List of references: References Designation SAVNEG1585 CPR PM100A EVO/ PM100A EVO DIGITAL VALVE SAVNEG1556 MATTRESS TIP 3 CONNECTORS SAVNEG1601 TOP BOX SMAT DYNADJUST/ PM100AEVO/ DIGITAL SAVNEG1600 LOWER BOX SMAT DYNADJUST/ PM100AEVO/ DIGITAL SAVNEG1603 CELL WITHOUT PA DYNADJUST/ PM100AEVO/ DIGITAL...
  • Page 15: Valve Cpr

    WINNCARE France ALVE CPR valve reference: References Designation SAVNEG1585 CPR PM100A EVO/ PM100A EVO DIGITAL VALVE - 15 -...