For a listing of pressures and corresponding temperatures see Chapter 6, Table 6.1.1. Hoffman also offers a wide variety of options for the steam generators and boilers. For a listing of the options available, please contact your Hoffman Distributor.
ELECTRIC STEAM GENERATORS & OILERS TECHNICAL MANUAL 1.3 PRELIMINARY DELIVERY INSPECTION INSPECT BOX/CRATE AND STEAM GENERATOR OR BOILER FOR SHIPPING DAMAGE AND SHORTAGE. ANY DAMAGE OR SHORTAGE IN SHIPMENT SHOULD BE NOTED ON THE FREIGHT BILL BEFORE IT IS SIGNED. CALL THE CARRIER IMMEDIATELY TO REPORT ALL DAMAGE OR SHORTAGE AND ARRANGE TO FILE A CLAIM.
WARNING ALWAYS PROPERLY GROUND THE UNIT BEFORE OPERATING. ONLY A LICENSED ELECTRICIAN SHOULD SERVICE OR INSTALL A HOFFMAN STEAM GENERATOR. 7. Installation in an enclosed space shall require the following clearance around the steam generator: Each Side and Front/Rear Clearance….2 FT –...
3.0 OPERATING INSTRUCTIONS Open the gauge glass valves on the top and bottom of the gauge glass assembly (on units supplied). 2. Check the drain valve to be certain that it is closed. 3. Filling the boiler: A. For Manual Water Feed Models: Open the water fill valve on the side of the boiler.
The Hoffman Electric Steam Generator/Boiler is easy to clean and easy to maintain. It is strongly suggested that the following steps be followed to ensure a long and trouble- free life for the boiler.
4. Open the petcock at the bottom of sight glass (if so equipped). 5. Remove the sight glass and clean with a bottle washer. Use a plastic bristle brush. A metal wire brush could scratch the glass and is not recommended. 6.
ELECTRIC STEAM GENERATORS & OILERS TECHNICAL MANUAL 5.0 TROUBLESHOOTING & SERVICING 5.1 TROUBLESHOOTING TABLE PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Check incoming power Lack of power Check fuses Check On/Off switch is in “ON” position Unit does not Lack of water Fill unit heat up Bad Heating...
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Breather valve See Section 3.0 – Operation not open Lightly tap valve Clean valve seat. Disconnect power and Check Valve is remove pressure from the boiler. Check no Can not fill stuck pressure by leaving the breather open with water Replace valve Water Inlet...
(To be performed by a licensed electrician) The heating element is an immersion type, flange mounted, designed particularly for the Hoffman boiler. An element can be wired either single phase or three phase. However, machine electrical modifications would be necessary...
5.6 REPLACING THE ELECTRIC FOOT SWITCH AND/OR CORD (To be performed by a licensed electrician) For Models: JEL-10, JEL-11, JEL-12 Turn off the power to the boiler by pulling the plug or turning off the power at the branch switch or the circuit breaker.
ELECTRIC STEAM GENERATORS & OILERS TECHNICAL MANUAL 5. Disconnect the cord wires from the foot switch. 6. Check continuity through the switch while holding the switch lever down. If the switch passes the test, skip to number 10. 7. If the switch fails the continuity test, loosen two screws on the bottom side of the switch housing and remove the switch from the cord.
5.8 CLEANING THE ELECTRIC SOLENOID VALVE (To be performed by a licensed plumber) For Models: JEL-10, JEL-11, JEL-12 Turn off the power to the boiler by pulling the plug or turning off power at the branch switch or at the circuit breaker.
ELECTRIC STEAM GENERATORS & OILERS TECHNICAL MANUAL 6.0 TABLES 6.1 PRESSURE VS. TEMPERATURE The following table shows the relationship between steam pressure in pounds per square inch (psig), and temperature in degrees Fahrenheit (ºF). This table can be useful in determining the steam temperature at a corresponding pressure.
6.2 ELECTRICAL SPECIFICATIONS The following table lists voltage and amperage requirements of various models of Steam Generators. Table 6.2.1 MODEL VOLTAGE PHASE AMPS NUMBER 17/27 JEL-10 18/30 19/31 24/40 JEL-11 26/43 27/46 31/52 JEL-12 12.0 34/57 36/60 17/27 RHPG-15 18/30...