Fantasy
UK
IRL
Installation Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fantasy and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Faber Fantasy

  • Page 1 Fantasy Installation Guide...
  • Page 2 Figures < < < <...
  • Page 3 Figures > > > >...
  • Page 4: Table Of Contents

    Cleaning the glass ................10 Appendix A: Example calculation..............11 Appendix B: Flue restrictor................12 Appendix C: Installation of the flue..............13 Appendix D: Technical specifications Fantasy............14 Appendix E: Dimensions Fantasy..............15 Appendix F: Dimensions Ventilation Grid ............16 <...
  • Page 5: Introduction

    1 Introduction Note: these instructions should be read carefully and retained for future reference. Please leave these instructions with the user. Special features: • Room sealed appliance, inlet and outlet are led to the outside using a natural draught concentric pipe system (100 mm/150 mm) (no power fan required). •...
  • Page 6: Safety And General Information

    2 Safety and general information Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible. This gas appliance is factory set and can not be adjusted. This appliance does not contain any component manufactured from asbestos or any asbestos related products.
  • Page 7: Installation Requirements

    The appliance is of the type C11/C31. The appliance will need to be supplied with the approved Faber flue pipes and terminal, it is not possible to supply your own. The minimum effective height of the flue system must be 1 meter.
  • Page 8: Flue Restrictor

    2. each 45-degree bend, which is in the horizontal area, counts for 1 meter; 3. elbows and bends at the transition from horizontal to vertically are not to be counted; 4. the wall mounted terminal counts for 1 meter. Flue restrictor If applicable, in the table of appendix B is also stated the size of a flue restrictor.
  • Page 9: Instruction For Installation

    4 Instruction for Installation Gas Connection Installation pipes should be in accordance with BS 6891. Pipe work from the meter to the appliance must be of adequate size. The complete installation including the meter must be tested for soundness and purged as described in the above code.
  • Page 10: Commissioning (Functional Checks)

    5 Commissioning (functional checks) Pilot ignition check • Ignite the pilot light as described in the user manual. • Check if the pilot burner stays alight. • Extinguish the pilot burner. Check functional burner and pilot burner The appliance is preset to give the correct heat input. No further adjustment is necessary. Always check the inlet pressure and burner pressure: •...
  • Page 11: Handing Over (Final Check And Customer Briefing)

    6 Handing over (final check and customer briefing) Instruct the customer on the full operation of the appliance and the remote control, including replacement of batteries. Advise the customer how to clean the appliance including the glass. Hand over these instructions including the user guide to the consumer. Recommend that the appliance should be serviced by a competent person at least once a year.
  • Page 12: Appendix A: Example Calculation

    Appendix A: Example calculation Calculation 1: Calculating horizontal extension fig. 2a: Flue length C + E = 1m + 1m Elbows D = 2m Total horizontal extension Measure or calculate effective height (Hvert) Flue length A Roof mounted terminal Total effective height Always check if the calculated situation is allowed (see appendix B: Flue restrictor) Calculation 2:...
  • Page 13: Appendix B: Flue Restrictor

    Determine according to the table the right flue restrictor size. • When meeting an X, and when the values are outside the table, the combination is not allowed. • Normally the 30 mm flue restrictor is pre-installed. Horizontal length (m) Fantasy > > > >...
  • Page 14: Appendix C: Installation Of The Flue

    Appendix C: Installation of the flue Connection with use of concentric duct material Make a hole of ø 153 mm for the wall or roof mounted terminal. The horizontal pipes need to rise away from the appliance at a rate of 3 degrees per metre.
  • Page 15: Appendix D: Technical Specifications Fantasy

    Appendix D: Technical specifications Fantasy Country UK / IRL UK / IRL II 2H3+ II 2H3+ Appliancetype C11 of C31 C11 of C31 Reference gas Input (nett) Efficiency class Inlet pressure Mbar Gas rate* Gas rate* gram/h Working pressure (high) Mbar 10.5...
  • Page 16: Appendix E: Dimensions Fantasy

    Appendix E: Dimensions Fantasy 15 < < < <...
  • Page 17: Appendix F: Dimensions Ventilation Grid

    Appendix F: Dimensions Ventilation Grid > > > >...
  • Page 18 17 < < < <...
  • Page 19 > > > >...
  • Page 20 – info@faber.nl Saturnus 8 NL - 8448 CC Heerenveen Postbus 219 NL - 8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501 40010...