Content Safety Instructions ......................... 4 Information about this Operation Instructions ................4 Warning Information System ..................... 4 Qualified Personnel ........................4 Intended Use ..........................4 Liability Limitation ........................4 Recycling ........................... 5 ROQSTAR Ethernet Switches ....................... 6 Models Described in this Manual ....................7 Interfaces ..........................
Intended Use Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that TRONTEQ products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.
► Disregard of the operating instructions in this manual ► Improper use ► Employment of non-qualified personnel ► Unauthorized technical modification or reconstruction The general terms and conditions are valid as well as the delivery terms of the manufacturer and the legal regulations which were taken when the contract was concluded.
ROQSTAR Ethernet Switches ROQSTAR Ethernet Switches are designed for use on public transport vehicles. They ensure the interconnection of Ethernet devices on an Ethernet network and facilitate the IP based communication for on board equipment of a public transport vehicle. ROQSTAR Unmanaged These devices are characterized by their simplicity.
Interfaces Description Description mounting holes USB port model label port LED status LED Ethernet port power port ground terminal M6 Installation Guide 2023-10-18 ROQSTAR 16-Port Managed Gigabit Ethernet Switch Page 8 of 16...
Installation Never perform wiring under voltage Do not perform any installation under voltage WARNUNG! Installation Guidelines Follow the steps below to install the device ► For installation choose a location with a flat plane ► Prepare the drill holes at the installation location for the device mounting holes ►...
Power Port The ROQSTAR device provides two power ports. For Ethernet Switch function apply power supply to V1 or V2. For PoE function the power supply must be applied to V1. V1 supplies both, Ethernet and PoE function V2 supplies Ethernet function only Connector type: M12 L-coded, 4 pins, male Name Signal...
Start Up and Operation A managed ROQSTAR model starts boot-up process after a valid supply voltage is applied. After boot- up process is finished, ROQSTAR Ethernet switch behaves according to configured settings. If no user configuration is saved or available, factory settings are loaded. Factory Settings ►...
Bypass Relay This feature is intended for bypassing the traffic between two dedicated ports, if ROQSTAR device is not powered or not in operation mode. The ports affected by this function called bypass ports. A relay provides electrical connection between these ports. The relay is switched on/off by operating state of the ROQSTAR device.
Technical Data Electrical Power Port parameters, standard model min. typ. Max. Dimension Operating voltage SELV +9.6 Reverse polarity protection - 60 Reset level Current consumption, all port with data transfer V1 = 9.6V Peak inrush current <1ms 10 @ 9.6V 14 @ 60V Power consumption, all port with data transfer Immunity of power interruption...
PoE parameters min. typ. max. Dimension Voltage Current limit PoE class 0/3 Current limit PoE class 1 Current limit PoE class 2 Current limit PoE class 4 Internal fuse per port 1500 Total PoE output power budget Data Transfer Ethernet-Ports min.