1.2 Copyright notice The copyright of this user manual is owned by Growatt. No part or all of this user manual may be excerpted, reproduced or transmitted in any form, including information and publications, by any entity or individual without our written permission.
Meter Air disconnect switch Terminals The ShineSEM-XA-R is mainly composed of ShineMaster4G-X, electric meter, air isolating switch, and terminal block The functions of each part are as follows: 1. ShineMaster4G- X : the control core, which communicates with the inverter and the meter to realize the functions of remote monitoring, setting, upgrading, and collecting relevant operating information of the inverter.
Page 6
ShineMaster4G-X status LED lights, which can display the running status of ShineMaster4G-X. Figure 2- 3 Indicator lights Indicator light Meaning A. Power indicator Always off: The power supply is working abnormally; Power LED Steady on: The power supply is working normally. Always off: Bluetooth is not enabled;...
Page 7
The switch is switched off by default at the factory. The power meter and ShineMaster4G-X are in a powered off state. The power meter and ShineMaster4G-X work properly when powered up. Figure 2-4 Terminal block 4 wiring ports in the terminal block, which are as follows from left to right: (a) Three-phase voltage output interface (L 1 , L 2 , L 3 ) (b) Single-phase power input interface (L, N) The ammeter is an optional component, and it is used with the anti-reflux box...
2. The electric energy generated by the inverter can be used for user load or output to the grid, 3. The ShineSEM-XA-R is located between the inverter, the user load and the grid, and communicates with the inverter through RS485 .
ShineSEM-XA-R to the wall, and then install the Hang up the communication box of the smart sub-array, and lock the screws to complete the installation.
③ ④ Figure 2-9 Install Expansion screw ST6.3 ⑤ Figure 2- 10 Installation and fixing Note: This product is supplied with a special key to lock the upper cover, which can be operated by the customer according to the actual situation. 2.5 Wiring instructions Open the upper cover of the communication box of the smart array , and connect according to the figure below.
Page 11
2. RS485 interface The ShineSEM-XA-R is used to connect the RS485 interface of the inverter. For the wiring method of multiple inverters, please refer to the following figure. The precautions are as follows:...
Page 12
(3) When installing the transformer, foreign matter such as impurities and dust must not fall into the cutting surface of the iron core, so as not to affect the performance of the transformer. (4) If the ShineSEM-XA-R is not equipped with an ammeter, no current transformer needs to be installed.
For details, please refer to Chapter 5. 6. Ground terminal To ensure the reliable operation and personal safety of the ShineSEM-XA-R, the ground terminal on the housing must be reliably grounded. Note: Pay attention to the waterproofing of the ground terminal.
Operation and application 3 3.1 ShineMaster4G-X operation introduction You can access the built-in page of ShineMaster - X through static IP or dynamic IP to set or modify parameters of ShineMaster4G-X. Connect PC and ShineMaster - X directly through network cable. The computer IP is changed to 192.168.0.XXX (XXX ranges from 2 to 253).
Page 15
Figure 3- 2 Schematic diagram of running window Figure 3-3 Schematic diagram of command line input Figure 3- 4 Schematic diagram of the results of the ipconfig command 3. Enter 192.168.1.254 in the computer browser to access the built-in page of ShineMaster4G-X .
2. Enter the user name and password, the default login user name: admin, password: admin, click login after filling in, enter the ShineMaster4G-X system page. Figure 3- 7 System information bar 3. The system page mainly includes the following four columns A.
Log in to the built-in page, the login account is "admin", the password is "admin", select "Device Monitoring" in the first-level menu, select "Inverter" in the second- level menu, and select "Device Maintenance" in the third-level menu. (1) Select the device to be added, "inverter", "electric meter", "environmental monitor"...
Page 18
Figure 3- 11 Channel selection (4) Select the device type in the drop-down list of "Type". Figure 3- 12 Device type selection (5) "Start address" writes the start address of the added device, for example: suppose the address of the photovoltaic inverter to be monitored is "1", then the start address is 1 .
Page 19
Figure 3- 15 Add success prompt Figure 3- 16 Device list The device types are as follows: Inverter GROWATT Inverter SDM one-way meter SDM three-way electric meter CHNT one-way meter Electric meter CHNT three-way electric meter...
Page 20
The deletion of equipment includes "inverter", "electric meter", "environmental monitoring instrument", and "PID equipment". The method of deleting devices is the same, taking the inverter as an example: (1) Log in to the built-in page, the login account is "admin", the password is "admin", select "Device Monitoring"...
Figure 3- 20 Delete prompt ( 4 ) After the prompt is successful, click "Query" again to check whether the deletion is successful; Figure 3- 21 Prompt for successful deletion Figure 3- 22 Device list When you need to use the remote monitoring function of ShineMaster4G-X, you need to set up its network.
Page 22
Figure 3- 23 Wired communication window ( 2 ) The DHCP function is turned off by default at the factory , and the DHCP function needs to be turned on to automatically obtain an IP address from the router. Figure 3- 24 DHCP enabled ( 3 ) After the setting is successful, it needs to be restarted to take effect.
Page 23
Figure 3- 27 Schematic diagram of server settings (2) Enter the port number of the corresponding server, the domain name of the server, such as server-cn.growatt.com/server.growatt.com , and the time interval for data uploading, click Submit, and it will prompt to refresh the interface successfully to check whether the modification is successful.
Figure 3- 29 Enable active power adjustment 1. Power drawn from the grid: the maximum power allowed to be drawn from the grid (load consumption + battery charging power). 2. Feed-in power: the power allowed to be fed to the grid (only the PV power can be exported to the grid, not the battery power) 3.
Page 25
Figure 3- 32 Time mode settings Multiple time mode settings. You can select Special Day 1, Special Day 2, Quarter (1, 2, 3 4) or Full year, as shown below: Figure 3- 33 Time mode settings Procedure to set the working mode for idle time is illustrate below: (1) Add a time segment.
Page 26
Figure 3- 34 Idle time settings (2) Click the “x” icon, then you can set the working mode for idle time based on the inverter model and on-site situations. Figure 3- 35 Idle time settings...
Page 27
(2) If the datalogger fails to communicate with the PV inverter and PCS over the failure time, the PV inverter and storage inverter will enter the Failure State and operate at the failure power level. When the communication is re- connected, the PV inverter and storage inverter will exit the Failure State.
Page 28
Single Phase Adjustment: read Phase A, B and C power of the meter. Adjust the Ÿ power of the PV inverter or storage inverter based on the power and direction of each phase. Note: (1) If set to “Disable”, the adjustment mode is “Total Phase Adjustment” by default.
Note: 1. During idle time, the working mode is set to Standby Mode by default if not configured. Idle time: all time that has not been configured. 2. Overlapping time segments are not allowed. For instance, if Quarter 1 is selected and the first time segment is set to 8:00 am - 10:00 am, then setting the second time window to 9:00 am -11:00 am would be invalid.
Enable (limited): Only the pre-configured client IP addresses are allowed to Ÿ connect to the ShineMaster4G-X server. Less than 3 client IP addresses can be connected and they are configurable. Figure 3- 37 IEC104 settings Note: All meters involved in the power plant relationship should be on the same node.
Figure 3- 39 Adding nodes Figure 3- 40 Power plant relationship Show 1. If the interface is not refreshed for a long time after clicking Save when adding a device, power off and restart the collector. After restarting, click "Device Status" to check whether the last operation was successful.
Specification parameters and 4 model description 4.1 Specification parameters ShineSEM-XA-R (with electric meter) Technical Parameters Input voltage parameter Rated input voltage/range 400Vac (three specifications) Rated input frequency/range 50/60Hz Grid connection type 3W/N/PE Input current and CT parameters Maximum detection current...
4.2 Model description ShineSEM-XA-R ① ②③ ④⑤ The model introduction of the ShineSEM-XA-R takes ShineSEM-XA-RA-RL EU as an example: logo meaning Value ①ShineSEM Product Identification ShineSEM: Communication Box X: 1st generation, X2: 2nd ②XX Model representative generation, in descending order ③A...
Contact us 5 Growatt New Energy provides customers with comprehensive technical support. Users can contact the nearest Growatt New Energy office or customer service point, or directly contact the company's customer service center. Shenzhen Growatt New Energy Co., Ltd. 4-13/F, Building A, Sino-German (Europe) Industrial Park,...