Summary of Contents for Dracal Technologies TRH200
Page 1
User Manual TRH200 USB Temperature and Humidity Sensor With an Exposed End Model name Part number Description USB-TRH200 601032 USB temperature and humidity sensor with an exposed end USB-TRH200-CAL 608032 USB temperature and humidity sensor with an exposed end – calibratable...
6 Installation and Setup 6 Usage Guidelines and Applications 9 Care, Storage, and Recalibration 9 Troubleshooting Guide and Support 10 Return Process and Warranty Information 10 Accessories and Peripherals 10 Disassembly and Environmental Considerations 11 Document Revision History Dracal Technologies Inc.
It is available upon request to the relevant authorities. Signed for and on behalf of: Dracal Technologies Inc., January 2024 Ariane Garon President Dracal Technologies Inc. TRH200 – USB Temperature and Humidity Sensor With an Exposed End...
The TRH Series of instruments was designed for anyone interested in temperature and relative humidity (dew point). The TRH200: USB temperature and humidity sensor with an exposed end is the tool for hard surface monitoring or fast- response monitoring of temperature and relative humidity.
(t63% = 5 s), ensuring accuracy and responsiveness in diverse environments. Equipped with an exposed sensor, the TRH200 excels at measuring temperature on hard surfaces and can measure relative humidity levels up to 100% RH, making it suitable for various applications.
Connect an instrument. Launch DracalView. Verify the instrument appears in the Sources tab. Modify units and decimals in the Configuration tab (Optional). Customize the names of channels to record in the Sources tab (Optional). Visualize data on GraphView. Dracal Technologies Inc.
Page 7
Please refer to the TRH200 page for the complete guide, specifically the “Software & Documentation” tab. Of note, to log data with DracalView, these are the remaining main steps of the Getting Started guide: Initiate the logging task in the Logging tab.
Page 8
DracalView and the command-line tools. For additional information, please click the relevant link in the Software & Documentation section of the TRH200 page. Calibration “-CAL” suffix: If present, the product is equipped with a 3-point user-calibration mechanism.
If the instrument has a “-CAL” suffix, it can be adjusted for accuracy during the calibration. The long-term drift of the TRH200 is less than 0.03 °C per year. Therefore, depending on the user’s application, an adjustment might be required more frequently.
In most cases, there will be an easy solution. In the rare event of a faulty instrument under warranty, Dracal Technologies will proceed to a replacement upon evaluating the situation. The procedure will be explained through email once the customer advises support@dracal.com.
These USB sensors comply with CE (Conformité Européenne) and REACH (Registration, Evaluation, Authorization, and Restriction of Chemicals) regulations, meeting European safety and environmental impact standards. Document Revision History Version 1.0 2024-02-08 Creation of the User Manual. TRH200 – USB Temperature and Humidity Sensor With an Exposed End...
Need help?
Do you have a question about the TRH200 and is the answer not in the manual?
Questions and answers