ILC Dover Sentinel XT S-3301 User Instruction Manual

Full hood papr system

Advertisement

Quick Links

SENTINEL XT™ FULL HOOD
PAPR SYSTEM
MODEL NO. S-3301
Top Level Assy S-3300
USER INSTRUCTION MANUAL
ECO: 222-1009-01
S-3301
Rev. G

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sentinel XT S-3301 and is the answer not in the manual?

Questions and answers

Summary of Contents for ILC Dover Sentinel XT S-3301

  • Page 1 SENTINEL XT™ FULL HOOD PAPR SYSTEM MODEL NO. S-3301 Top Level Assy S-3300 USER INSTRUCTION MANUAL ECO: 222-1009-01 S-3301 Rev. G...
  • Page 2 ∆ WARNING IMPROPER USE OF THIS HOOD AND RESPIRATOR MAY RESULT IN PERSONAL INJURY OR DEATH. IMPROPER USE INCLUDES, BUT IS NOT LIMITED TO, USE IN ATMOSPHERES CONTAINING UNKNOWN CONTAMINATES AND/OR UNKNOWN CONCENTRATIONS CONTAMINANTS, WITHOUT ADEQUATE TRAINING, DISREGARD OF THE WARNINGS AND INSTRUCTIONS CONTAINED HEREIN...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS ITEM PAGE DESCRIPTION ....................2 GENERAL SAFETY INFORMATION ............4 REPLACEMENT PARTS ................8 COMFORT BELT CONFIGURATION ............9 PREPARATION FOR USE ................12 CHARGING THE LiPOLYMER BATTERY PACK ........12 BATTERY USAGE AND STORAGE REQUIREMENTS ......13 INSTALLING THE LiPOLYMER BATTERY PACK INTO THE BLOWER ....................
  • Page 4: Description

    DESCRIPTION The ILC Dover SENTINEL XT™ FULL HOOD PAPR SYSTEM is a blower-assisted air-purifying respirator known as Powered Air Purifying Respirator or PAPR. The SENTINEL XT™ FULL HOOD PAPR SYSTEM is comprised of the following components: Sentinel XT™ Full Hood, one size fits all P/N S-3113 The Sentinel XT™...
  • Page 5 Cartridge P/N S-2027 (Optional) The ILC Dover SENTINEL XT™ FULL HOOD PAPR SYSTEM alternative filter option utilizes three Chlorine/Hydrogen Chloride/Sulfur Dioxide/Chlorine Dioxide/Ammonia/Methylamine/Formaldehyde/High Efficiency Particulate Air cartridges. Comfort Belt P/N S-3104 This is a comfortable blower mounting option that allows quick and easy attachment or removal of the blower from the belt using clip-on mounting feature.
  • Page 6: General Safety Information

    GENERAL SAFETY INFORMATION Intended Use The ILC Dover SENTINEL XT™ FULL HOOD PAPR SYSTEM can be used as a belt mounted blower unit, connected to the hood via a flexible breathing tube. The ILC Dover SENTINEL XT™ FULL HOOD PAPR SYSTEM must be combined with the appropriate cartridges and battery pack.
  • Page 7 SYSTEM TO YOUR JOB SITUATION, CONSULT AN INDUSTRIAL HYGIENIST OR CALL ILC DOVER TECHNICAL SERVICE. Use the ILC Dover SENTINEL XT™ FULL HOOD PAPR SYSTEM for: Respiratory protection is provided against certain particulate contaminants and/or Organic Vapors, Acid Gases, depending on the selected cartridge.
  • Page 8 FAILURE TO DO SO MAY RESULT IN INJURY OR DEATH. NIOSH APPROVAL For a listing of the components in the ILC Dover respirator systems (ILC Dover SENTINEL XT™ FULL HOOD PAPR SYSTEM) that are NIOSH approved refer to the NIOSH approved label insert.
  • Page 9 D. Do not use this respirator if airflow is less than four cfm (115 lpm) for tight- fitting facepieces or six cfm (170 lpm) for hoods and/or helmets. E. Follow established cartridge/canister change schedules or observe ESLI to ensure that cartridges/canisters are replaced before breakthrough occurs. F.
  • Page 10: Replacement Parts

    REPLACEMENT PARTS Part No. Component Hood S-3113 Sentinel XT™ Full Hood Blower S-3114 Sentinel XT™ Blower Power Source S-3108 Lithium Polymer Battery Pack Cartridges and Plug S-4002 HE-High Efficiency Particulate Air (2/package) S-4012 (Optional) OV/CD/CL/HC/HF/SD/HE Cartridge (3/package) S-2027 (Optional) CL/HC/SD/CD/AM/MA/FM/HE Cartridge (3/package) S-4006 Blower Plug (with knob);...
  • Page 11: Comfort Belt Configuration

    ASSEMBLY AND PREPARATION FOR USE OF COMFORT BELT ILC DOVER SENTINEL XT™ FULL HOOD PAPR SYSTEM HE PROTECTION COMFORT BELT CONFIGURATION ECO: 222-1009-01 S-3301 Rev. G...
  • Page 12 ASSEMBLY AND PREPARATION FOR USE OF COMFORT BELT ILC DOVER SENTINEL XT™ FULL HOOD PAPR SYSTEM OV/CD/CL/HC/HF/SD/HE PROTECTION COMFORT BELT CONFIGURATION ECO: 222-1009-01 S-3301 Rev. G...
  • Page 13 ASSEMBLY AND PREPARATION FOR USE OF COMFORT BELT ILC DOVER SENTINEL XT™ FULL HOOD PAPR SYSTEM CL/HC/SD/CD/AM/MA/FM/HE PROTECTION COMFORT BELT CONFIGURATION ECO: 222-1009-01 S-3301 Rev. G...
  • Page 14: Preparation For Use

    PREPARATION FOR USE USING COMFORT BELT Open the package and take out the components: Sentinel XT™ Full Hood Users Instruction Manual S-3301 • Sentinel XT™ Full Hood S-3113 • Sentinel XT™ Blower S-3114 • Lithium Polymer Battery S-3108 • HE- High Efficiency Filter Particulate Air Cartridge S-4002, 2 each •...
  • Page 15: Battery Usage And Storage Requirements

    charging cradle. Be sure to insert the pack far enough down to hear/feel an engagement click. If the battery • is not fully charged the LED light on the charger will change from green to red, indicating that charging is underway. Charge the •...
  • Page 16: Installing The Lipolymer Battery Pack Into The Blower

    With a fully charged LiPolymer Battery the approximate run time of • the Sentinel XT™ is 12 hours. Charge battery upon receipt unless storing for more than 1 month. • In order to maintain proper battery performance; the battery must be •...
  • Page 17 STANDARD FOUND IN 29 CFR 1910.134 PRIOR TO USING ANY RESPIRATOR SYSTEM. BEFORE USE, THE USER MUST BE TRAINED BY THE EMPLOYER IN THE PROPER USE AND MAINTENANCE OF THE ILC DOVER SENTINEL XT™ FULL HOOD PAPR SYSTEM. SUCH TRAINING MUST BE IN ACCORDANCE WITH THIS USER INSTRUCTION.
  • Page 18: Cartridge Installation

    Cartridge Installation The SENTINEL XT™ FULL HOOD PAPR system uses two (2) HE cartridges that thread into the blower inlets as shown. The third blower inlet must be plugged using the standard plug with knob (S-4006) or with the flat plug (S-4007). Note: Screw in Note: Screw in both HE cartridges...
  • Page 19: Blower Plug Installation And Airflow Check

    ∆ WARNING DO NOT OVER TIGHTEN CARTRIDGE. OVER TIGHTENING MAY RESULT IN DISTORTION OR DISPLACEMENT OF THE SEAL AND ALLOW CONTAMINATED AIR TO ENTER THE RESPIRATOR HEADPIECE. RESULTING IN INJURY OR DEATH. Blower Plug Installation S-4006 blower plug with knob Verify that the blower plug and blower inlet connection thread are not •...
  • Page 20 If using the blower cover, be sure to re-check that blower plug is • installed prior to operation. Optional Cartridges Blower plug is not used with S-4012 and S-2027 Cartridges. • Airflow Check with the Flow Meter Ensure that the cartridges and plug are installed on the blower. •...
  • Page 21: Installing The Blower Onto The Comfort Belt

    Installing the Blower onto the Comfort Belt A. Comfort Belt (S-3104) Align the two mounting clips with the blower slots. A. Engage the clips into the blower slot and listen for the audible click ensuring they are locked into place. Positioning the blower on the Decon and Quick Release Belt and Clip.
  • Page 22 ∆ WARNING DO NOT ALLOW THE BLOWER COVER TO INTERFERE WITH THE FILTER INLETS OR BREATHING TUBE CONNECTOR. THIS MAY RESULT IN FAILURE OF ONE OR MORE OF THE CARTRIDGES OR BREATHING TUBE TO SEAL AND ALLOW CONTAMINATED AIR TO ENTER THE RESPIRATOR HEADPIECE RESULTING IN INJURY OR DEATH.
  • Page 23: Connecting The Breathing Tube To The Hood And Blower

    11. Connect the Hood to the Breathing Tube and to the Blower Check that both ends of the breathing tube threads have the black • rubber gasket seal present. Check that the thread in the blower unit is in good condition and clear of anything that might prevent achievement of a good seal.
  • Page 24: 12. Donning The Hood With A Suit Configuration

    IF YOU HAVE ANY DOUBTS ABOUT THE APPLICABILITY OF THE EQUIPMENT TO YOUR JOB SITUATION, CONSULT AN INDUSTRIAL HYGIENIST OR CALL THE TECHNICAL SERVICE DEPARTMENT OF ILC DOVER AT (800) 631-9567. DO NOT REACH YOUR HAND INTO THE HOOD IN AREAS WHERE CONTAMINATED.
  • Page 25 Comfort Belt Donning Sequence (S-3104) Step 1 Step 2 Turn on the blower. Allow the After the belt is adjusted, pull the hood/breathing tube to drape down, Sentinel XT™ Full hood over then wrap the comfort belt around your head. your waist and snap the belt buckles together.
  • Page 26 Step 5 Tuck the inner hood skirt all way Step 6 around your neck and shoulders Front view of the completed into the suit. Be sure to tuck the donning sequence. inner skirt all the way down into the suit to prevent it coming loose and pulling out during use.
  • Page 27 29 CFR 1910.134 PRIOR TO USING ANY RESPIRATOR SYSTEM. BEFORE USE, THE USER MUST BE TRAINED BY THE EMPLOYER IN THE PROPER USE AND MAINTENANCE OF THE ILC DOVER SENTINEL XT™ FULL HOOD FULL HOOD SYSTEM. SUCH TRAINING MUST BE IN ACCORDANCE WITH THIS USER INSTRUCTION.
  • Page 28: Removing The Papr System

    SYSTEMS MUST FIRST READ AND UNDERSTAND THIS ENTIRE USER INSTRUCTION. FAILURE TO DO SO MAY ADVERSELY AFFECT RESPIRATOR SYSTEM PERFORMANCE AND RESULT IN INJURY OR DEATH. IF THESE RESPIRATOR SYSTEMS FAIL ANY OF THE REQUIREMENTS OF THE USER INSPECTION AND PERFORMANCE CHECK, DO NOT USE THE RESPIRATOR SYSTEM UNTIL ALL NECESSARY REPAIRS HAVE BEEN PERFORMED AND THE RESPIRATOR SYSTEMS PASS THE...
  • Page 29: Cleaning

    Breathing Tube Carefully examine the entire breathing tube. Look for tears, holes or cracks. Bend the tube to verify that it is flexible. Blower Remove the cartridges and assure that the rubber gaskets are in place in the blower. Examine the blower housing for cracks. Replace if cracked or damaged. Examine the outside of the battery pack for cracks.
  • Page 30: Storage

    ∆ WARNING CLEAN SENTINEL XT™ FULL HOOD WITH DETERGENTS THAT CONTAIN LANOLIN OR OTHER OILS SINCE THEY MAY SOFTEN OR DISTORT THE VISOR. DO NOT WIPE THE VISOR WITH SOLVENTS LIKE MEK, ACETONE, TOLUENE, AS THOSE MAY DAMAGE OR DISTORT THE VISOR.
  • Page 31: Customer Service

    DAMAGED BATTERIES MAY RESULT IN INJURY OR DEATH. CUSTOMER SERVICE INFORMATION If you need additional information on the Sentinel XT™ Full Hood PAPR or any ILC Dover product, consult your distributor or contact: Customer Service ILC Dover One Moonwalker Road Frederica, DE 19946-2080 Phone: 800.631.9567 OR 302.335.3911, ext.
  • Page 32: Troubleshooting

    Replace cartridges. PAPR blower malfunction. Switch to a different blower unit. Blower gasket is Gasket is not properly Contact ILC Dover Customer raised, twisted, or seated into the blower and Service Department has any visible may produce a leak path...
  • Page 33 THIS PAGE INTENTIONALLY LEFT BLANK ECO: 222-1009-01 S-3301 Rev. G...
  • Page 34 THIS PAGE INTENTIONALLY LEFT BLANK ECO: 222-1009-01 S-3301 Rev. G...

Table of Contents