Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series INDICE 1. GENERALITA’ ..........................7 CONDIZIONI DI FORNITURA ...................7 FABBRICANTE .........................7 CONTENUTO DEL LIBRO D’USO ..................7 DESIGNAZIONE, TIPO .....................8 EMISSIONI SONORE .......................8 CAMPI E LIMITI DI APPLICAZIONE. USI CONSENTITI E NON ........8 2.
Page 4
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series 5. MESSA IN SERVIZIO, FUNZIONAMENTO, ARRESTO .............. 16 DOCUMENTAZIONE ...................... 16 PREPARAZIONE DELLA POMPA PER IL FUNZIONAMENTO........16 5.2.1 Riempimento / scarico ..................16 5.2.2 Connessioni elettriche ..................16 5.2.3 Verifica del senso di rotazione ................
Page 5
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series CONTENTS 1. GENERAL INFORMATION ......................25 SUPPLY CONDITIONS ....................25 MANUFACTURER ......................25 USER MANUAL CONTENT .................... 25 NAME, TYPE ........................26 NOISE EMISSIONS ......................26 APPLICATION FIELDS AND LIMITS. ALLOWED AND NOT ALLOWED USES ....26 2.
Page 6
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series 4. COMMISSIONING, OPERATION, SHUTDOWN ................. 34 DOCUMENTATION ......................34 PUMP PREPARATION FOR STARTUP ................. 34 4.2.1 Filling / discharge ....................34 4.2.2 Electrical connections ..................34 4.2.3 Verifying the direction of rotation .................
(serie WPP, unicamente per pompe ad asse nudo) oppure tramite lanterna (serie WPL). FABBRICANTE Il Fabbricante della pompa è la POMPE CUCCHI S.R.L., cui ci si può rivolgere per assisten- za, al seguente indirizzo: Via dei Pioppi 39 - 20073 OPERA (MI) ITALY Tel.
La Pompe Cucchi s.r.l. declina ogni responsabilità riguardo alle conseguenze derivanti da un utilizzo della pompa non conforme a quanto indicato nel presente manuale o all'atto...
ZINAMENTO GENERALITA’ La Pompe Cucchi vende “franco fabbrica”. Conseguentemente il trasporto dall’officina di produzione al luogo di destinazione è a cura e sotto la responsabilità del Cliente. Per ogni trasporto è assicurato un imballo adeguato standard oppure secondo le specifiche del Clien- te che, in ogni caso, è...
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series IMMAGAZINAMENTO PER LUNGO PERIODO Per quanto riguarda i motori, consultare le istruzioni di uso e manutenzione del Fornitore. Le pompe devono essere conservate al coperto, in un ambiente pulito, asciutto, senza umi- dità...
La pompa viene normalmente fornita corredata di tenuta meccanica. Se il tipo di tenuta è prescritto dal Cliente, la Pompe Cucchi s.r.l. installa la tenuta richiesta dopo aver verificato la compatibilità delle dimensioni della tenuta con quelle della pompa. Se il Cliente richiede solo la marca della tenuta, l’Azienda fa selezionare il tipo di tenuta alla Casa costruttrice,...
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series INSTALLAZIONE, MONTAGGIO ATTREZZI SPECIALI PER IL MONTAGGIO La pompa non richiede attrezzi speciali per il montaggio, ad eccezione degli estrattori della tenuta (vedi Manutenzione). DATI RELATIVI AL SITO DI INSTALLAZIONE Requisiti spaziali per il funzionamento e l’installazione 4.2.1 Lo spazio previsto dal Cliente per l’installazione deve essere sufficiente per l’allocazione del...
Page 13
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series In caso contrario, interpellare il nostro Ufficio Tecnico. Fig. Ogni pompa deve avere una propria tubazione di aspirazione; il montaggio di due o più pompe aventi un tratto di tubazione in aspirazione in comune provoca interferenze idrauliche durante il funzionamento (Fig.III).
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series INSTALLAZIONE INIZIALE A seconda delle condizioni di fornitura si distinguono due casi: 4.3.1 Gruppo di pompaggio completo In questo caso il Cliente deve provvedere al fissaggio rigido del gruppo in modo da garantire il corretto allineamento degli assi in tutte le condizioni di funzionamento.
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series MONTAGGIO DELL’AZIONAMENTO E DEGLI ACCESSORI 4.4.1 Motore L’Azienda monta motori elettrici a norma CE, di potenza adeguata a quella della pompa, se- lezionati in base alle previste condizioni di servizio ed alle caratteristiche dell’ambiente. In particolare se il gruppo è...
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series 4.6.3 Coppie di serraggio per le viti La coppia di serraggio per le viti delle nostre pompe deve essere: - per viti da M6 11-12 Nm - per viti da M8 20-22 Nm - per viti da M10 38-40 Nm...
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series 5.3.2 Isolamento acustico I valori di emissione acustica sono riportati nel presente manuale. L’Utente dovrà sempre verificare se i regolamenti del proprio Paese prevedono, in relazione alla frequenza di espo- sizione e/o ai valori di emissione, l’uso di dispositivi di protezione individuale.
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series Requisiti dell’impianto relativi alla pompa 5.4.3 Nelle pompe volumetriche, la prevalenza non dipende dalla portata e/o dalla velocità di rota- zione; di conseguenza bisogna evitare di installare sulla tubazione di mandata valvole di in- tercetto e, comunque, tra la pompa e la valvola di intercetto deve essere sempre installata una valvola di sicurezza.
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series - Nel caso, prestare particolare attenzione agli effetti del tiro magnetico; in particolare fare attenzione alle dita (utilizzare guanti di sicurezza) ea non danneggiare i magneti con urti accidentali. Si raccomanda di utilizzare utensili in materiale amagnetico. - Predisporre un recipiente per la raccolta del liquido presente nella pompa.
Page 20
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series 1) Tenuta singola (vedi Figura 1) a) Accesso alla tenuta meccanica Separare la lanterna dal motore svitare il grano e smontare il giunto . Smontare la fa- scetta ...
Page 21
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series Creare un riferimento sul corpo centrale per impedire di invertire i piani di appoggio al ri- montaggio ed estrarlo unitamente alle 2 guarnizioni O-ring in esso alloggiate; l’operazione potrebbe essere resa difficoltosa per la precisione degli alberi e delle spine di centraggio .
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series GUASTI: CAUSE E RIMEDI Qui di seguito vengono brevemente elencate le cause più frequenti di anomalie nel funzio- namento delle pompe e sono citati i possibili rimedi.
Page 23
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series...
Gear Pump - WP, WL Series CONDIZIONI DI GARANZIA La Pompe Cucchi s.r.l. garantisce le pompe ed i gruppi di pompaggio esenti da vizi e/o da difetti di fabbricazione e di assemblaggio per un periodo di 12 (dodici) mesi dalla data di consegna (indicata sul D.D.T.).
The coupling can be direct (WPP series, only for bare shaft pumps) or through bell housing (WPL series). MANUFACTURER The pump Manufacturer is POMPE CUCCHI S.R.L.. You can apply for assistance by send- ing a request to the following address: Via dei Pioppi 39 - 20073 OPERA (MI) ITALY Tel.
Pompe Cucchi S.r.l. declines every responsibility for the consequences arising from an im- proper use of the machine which does not comply with what prescribed in this manual or...
TRANSPORT, HANDLING, PACKAGING, STORAGE GENERAL Pompe Cucchi sells “ex works”. Consequently, transport from the manufacturing shop to the named place of destination is carried out by the Customer under his own responsibility. For each transport a suitable standard packaging is ensured or established based on Customer requirements who, in any case, must give information about the type of shipment to be per- formed (by land, air, “overseas“).
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series STORAGE FOR LONG PERIOD As far as motors are concerned, please consult the operating and maintenance instructions of the Supllier. Pumps must be stored indoors, in a clean, dry, moisture-free and vibration-less environ- ment.
The pump is usually supplied equipped with mechanical seal. If the Customer requires a particular type of seal, Pompe Cucchi S.r.l. installs the desired seal after verifying if its di- mensions are compatible with those of the pump. In case the Customer requires only the seal mark, the Company leaves the Manufacturer to select the type of seal, by giving infor- mation about the pumped liquid.
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series INSTALLATION, ASSEMBLY SPECIAL ASSEMBLY TOOLS To assemble the pump you do not need special tools, except for seal extractors (see Maintenance). INSTALLATION SITE INFORMATION 3.6.1 Space requirements for operation and installation The space destined by the Customer to the installation of the machine should be enough to gain access to, install and maintain the pump unit.
Page 31
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series Otherwise, contact our Technical Department. Fig. Each pump must have its own suction pipe; the installation of two or more pumps with a common suction pipe length causes the pump to work less efficiently (Fig.III). The length of the suction pipe must be reduced as much as possible to minimize pressure losses in such segment;...
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series INITIAL INSTALLATION According to the conditions of supply, the pump can be delivered as follows: 3.7.1 Complete Pump Unit In this case the Customer must stiffly fasten the pump unit in order to ensure the correct axis alignment in all operating conditions.
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series DRIVE UNIT AND ACCESSORY ASSEMBLY 3.8.1 Motor The Company installs EC approved electric motors, of power compatible with that required by the pump, selected according to the desired operating conditions and environmental characteristics.
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series 3.10.3 Fastening screw torques The fastening torque for the screws of our pumps shall be: - for M6 screws 11-12 Nm - for M8 screws 20-22 Nm - for M10 screws 38-40 Nm For more detailed information, contact our Technical Department.
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series 4.3.2 Acoustic insulation Sound emission values are specified in this manual. The User should always verify if the regulations of his own country prescribe, in relation to the frequency of exposure to emission values, the use of individual protection devices.
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series 4.4.3 Pump system requirements In volumetric pumps, pressure is not related to flow rate and/or rotation speed; therefore, avoid installing shut-off valves on the discharge pipe and, in any case, between the pump and the stop valve a relief valve must always be installed.
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series - Pay special attention to the effects of the magnetic pull force; in particular beware of fingers (always use safety gloves). Be careful not to damage magnets by acci- dental shocks.
Page 38
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series 1) Single seal (see Figure 1) a) Access to the mechanical seal Remove the lantern from the engine, unscrew the fastening pin and disassemble the coupling . Disassemble the clamp and disconnect the pump from the lantern ; re- move the feather key ...
Page 39
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series Draw a reference mark on the main body to avoid reversing base planes on reassembly and remove it together with the 2 O-ring gaskets housed in it; the operation may become difficult for the accuracy of shafts and dowel pins .
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series FAULTS: CAUSES AND SOLUTIONS Here below the most common causes of malfunctions in the operation of pumps are shortly listed together with the possible solutions.
Page 41
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series...
- the pump was not tampered with; - the pump is returned to Pompe Cucchi s.r.l. clean, after removing any trace of the process fluid and in a proper packaging; - a short description of the fault is provided in writing together with the operating parameters of the pump or the pump unit;...
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series ALLEGATI/ANNEXES Le operazioni di manutenzione e lo smontaggio della pompa vanno effettuate unica- mente da personale autorizzato e specificamente addestrato. I portatori di pacemaker devono stare ad almeno 2 metri di distanza dai giunti magne- tici o dalle pompe con tale tipo di giunto.
Page 44
Pompa ad Ingranaggi - Serie WP, WPL Gear Pump - WP, WPL Series Figura 1 Figure 1...
Page 45
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series...
Page 46
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series Figura 2 Figure 2...
Page 47
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series...
Page 48
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series Istruzioni supplementari per l’esercizio e la manutenzione di pompe e gruppi destinati all’uso in atmosfere potenzialmente esplosive (Direttiva 2014/34/UE) La direttiva 2014/34/UE (che abroga la Direttiva 94/9/CE, nota anche come ATEX), è entrata in vigore il 30/04/2014 e riguarda “gli apparecchi ed i sistemi di protezione destinati ad essere utilizzati in atmosfera po- tenzialmente esplosiva”.
Page 49
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series Non è consentito l’utilizzo della pompa con parametri diversi da quelli definiti in ordine, se non espressamente autorizzato per iscritto dal Fabbricante. POMPE SERIE WLX, WLZ La marcatura delle pompe per l’utilizzo in ambienti con atmosfere potenzialmente esplosive è la seguente: II 2G Ex h T4-T1 Gb X per pompe ad albero nudo...
Page 50
Cliente, devono sottostare ai requisiti della Direttiva 2014/34/UE. Qualora si avessero dubbi sulla possibilità di impiego della pompa rivolgersi a: Pompe Cucchi S.r.l. Via dei Pioppi, 39 - 20073 Opera (MI) Tel. 02 57606287 Fax. 02 57602257 E-mail: sales@pompecucchi.it...
Page 51
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series Verificare il corretto allineamento fra pompa e motore elettrico, seguendo le istruzioni del libretto d’uso della pompa e le avvertenze del Costruttore del giunto elastico o del giunto magnetico. Accertarsi che le tubazioni abbiano diametro adeguato (sul lato aspirazione, in particolare, il dia- metro non deve essere inferiore al valore nominale della connessione della pompa), che non vi ATTENZIONE...
Page 52
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series Non avviare mai la pompa a secco. Il liquido pompato, oltre a provvedere alla lubrificazione degli ingranaggi, svolge anche la funzione di lubrificare e raffreddare i supporti e la tenuta meccanica o il magnete interno ed il “bicchiere”.
Page 53
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series Supplementary instructions for operation and maintenance of pumps and pumping sets which work in potentially explosive atmospheres (Directive 2014/34/EU) Directive 2014/34/EU (that replaces Directive 94/9/EC, also known as ATEX), came into force on 30/04/2014 and concerns “equipments and protective systems intended for use in potentially explosive atmospheres”.
Page 54
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series PUMPS TYPE WPLX, WPLZ The marking of the pumps intended for use in potentially explosive atmospheres is as follows: II 2G Ex h T4-T1 Gb X for base shaft pump II 2G Ex h db IIB (or IIC) T4-T1 Gb X for pumping unit ATTENTION...
Page 55
Customer, must be in accordance with requirements of the directive ATTENTION 2014/34/EU (ATEX). If you have any doubt concerning the operation limits of the pump, please contact: Pompe Cucchi S.r.l. Via dei Pioppi, 39 - 20073 Opera (MI) - Italy Tel. +39 02 57606287 Fax. +39 02 57602257 E-mail: sales@pompecucchi.it...
Page 56
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series Wherever foreseen, check the connection of the thermocouples and of their related accessories ATTENTION with detecting equipment and with alarm signal and stop device of the pump and of the motor. We remind you that every protection device, safety component and safety, control and regulat- ing device installed by the Customer, must be in accordance with requirements of the Directive 2014/34/EU...
Page 57
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series An equipment for detecting outlet flow, joined to an alarm signal and a stop device of the pump, is recommended. Before starting on, be sure that both upstream and downstream stop cocks are open and filter is not stopped up.
Page 58
DECLARATION OF CONFORMITY POMPE CUCCHI S.r.l. declares, under its own responsibility, that the pump units series B, F, FM, FT, MG, MX, N, WPP, WL, CP, CPP, CMP, CM, DMP, AM5, S, SK are in accordance with the following Directives:...
Page 59
DICHIARAZIONE DI INCORPORAZIONE PER FORNITURA DI POMPE AD ASSE NUDO La POMPE CUCCHI S.r.l. dichiara, sotto la propria esclusiva responsabilità, le pompe serie B, F, FM, FT, MG, MX, N, WPP, WPL, CP, CPP, CMP, CM, DMP, AM5, S, SK sono conformi per progetto a quanto prescritto dalla Direttiva 2006/42/CE.
Page 60
Pompa ad Ingranaggi - Serie WP, WL Gear Pump - WP, WL Series Edizione: 01/2021 Edition: 01/2021 POMPE CUCCHI s.r.l.