  • Page 3: General Safety Information

    3mm in all poles. • SPL (2021) Ltd accepts no responsibility for any damage or injury to property or persons caused by improper, incorrect or unreasonable use or installation.
  • Page 4: Specifications

    Operating Instruction and Parts Manual Please read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage.
  • Page 5: Installation Instructions

    Installation Instructions 1. Wall Bracket Removal 1. Place the main cover on a cloth to avoid marking its surface. 2. Using the security key provided, remove one security screw located on the bottom of the unit. (Fig 2). 3. Pull down the wall mounting bracket and remove from the unit. (Fig 3). 2.
  • Page 6 3. Installing Power Cable and Connection Terminal Block 1. Pull the cable through the hole in the wall mounting bracket. Ensure the cable is long enough to route correctly through the wall mounting bracket to the terminal block (Fig 6). 2.
  • Page 7 The unit has a built in UV-C lamp, avoid exposure to direct germicidal UV rays. Options: Heater, Quiet Mode & Air Sterilisation IMPORTANT: Turn power OFF at the isolater switch before performing next steps. 1. Remove one security screw located on the bottom of the unit, using the security hex key provided (Fig 2).
  • Page 8 HEPA Filter Replacing Red flashing LED light on front of unit indicated HEPA filter needs replacing. The filter functions for approximately 60,000 operations. 1. Remove the filter cover shown in pages 7 & 8. 2. Turn the filter cover to open direction (Fig 10). The dot is aligned with the arrow present on the motor cover (Fig 10A).
  • Page 9 WARNING - HEPA filter will need to be replaced after 60,000 operations but will continue working for a further 15,000 operations without the benefits of the HEPA filter. At approximately 75,000 operations the red LED will begin to flash and the unit will stop working until a replacement filter is fitted.
  • Page 10: Maintenance And Cleaning

    Maintenance and Cleaning Regular Maintenance Cleaning and maintenance must not be undertaken until the unit has been removed from the mounting bracket and power has been disconnected. 1. Regularly clean the outer casing using a soft, damp cloth to gently wipe away any dirt CAUTION: Never use abrasives or chemical to clean the cover.
  • Page 11: Troubleshooting

    Troubleshooting Symptom Possible Cause Corrective Action Filter is not fitted Refit HEPA filter, making sure Red LED continues to flash after replacing correctly the dot is aligned to the right HEPA filter arrow on the motor cover. Dryer fails to start Defective PCB If no LED’s are list above and supply circuit is confimred to...