SPL SUPREME AIRJET Installation & Maintenance Instructions Manual

SPL SUPREME AIRJET Installation & Maintenance Instructions Manual

Advertisement

Quick Links

Installation
& maintenance
instructions.
1
splwashrooms.co.nz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUPREME AIRJET and is the answer not in the manual?

Questions and answers

Summary of Contents for SPL SUPREME AIRJET

  • Page 1 Installation & maintenance instructions. splwashrooms.co.nz...
  • Page 2 splwashrooms.co.nz...
  • Page 3: General Safety Information

    3mm in all poles. • SPL (2021) Ltd accepts no responsibility for any damage or injury to property or persons caused by improper, incorrect or unreasonable use or installation.
  • Page 4: Specifications

    Retain instructions for future reference. Supreme AIRJET Hand Dryer Supreme AIRJET hand dryer, is a surfaced-mounted dryer, powered by a universal brushed motor, delivering up to 950 watts of drying power. These models operate at all voltages 277VAC. The AIRJET incorporates an integrated heating element, selectable blower speed and infrared sensing for automatic activation.
  • Page 5: Installation Instructions

    Planning We suggest that one hand dryer be installed for every two hand basins. NOTE: Ensure that no reflective object (such as hand basin) is located directly under infra-red sensor eye; the minimum distance is 460mm. Installation Instructions 1. Disconnect the power source 2.
  • Page 6 Adjusting IR Sensor Distance IR sensing distances for automatic Supreme AIRJET are factory set between 100 -150 mm. In some installation environments, sensing distance may need to be adjusted lower due to environmental conditions to eliminate unattended activation or ghosting. Installation close to a reflective surface, exposure to natural sunlight or other nearby IR activated devices can be conditions causing unattended activation.
  • Page 7: Adjusting Blower Speed

    Adjusting Blower Speed These models include adjustable blower speed control for (3) levels of operation - Hi, Med and Low. The switch is located on the printed circuit board inside the dryer as shown in FIG 2. The factory setting for blower speed control is “Hi”.
  • Page 8: Diagnostic Led Display

    The printed circuit board includes a set of LED’s that indicate the operational status of the hand dryer. When contacting SPL Technical Service, be prepared to remove the dryer’s cover and provide the condition of the LED’s as they can be helpful in troubleshooting the dryer.
  • Page 9: Hepa Filter Replacement

    HEPA Filter Replacement High efficiency particulate absorbtion (HEPA) filters remove a minimum of 99.97% of contaminants 0.3 microns in size or larger. The service life of a HEPA filter depends on the environment in which the dryer is installed and frequency of use. High traffic washrooms or high usage will require more frequent inspection and replacement of the HEPA filter.
  • Page 10: Troubleshooting

    Troubleshooting Symptom Possible Cause Corrective Action Dryer fails to start Incoming power supply Remove cover and check diagnostic LEDs. If no LED’s are lit, check power supply at the circuit breaker/ fuse. Defective PCB If no LED’s are lit above and supply circuit is confirmed to be active, replace PCB and transformer.
  • Page 11 splwashrooms.co.nz...
  • Page 12 SPL (2021) Limited warrants that should any part of the dryer fail within the given warranty period (2- 5 years product dependant), it will be remedied by SPL.

Table of Contents