Page 1
IDENTIFICATION === Ende der Liste für T extm arke Deckbl att === INSTALLATION MANUAL ID CPR60 RFID Reader Module Model Article No. ID CPR60-A 5491.000.00 M91210-3e-ID-B...
Page 2
Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
Declaration of Conformity (CE) ..................15 Declaration of Conformity (UKCA) ................. 15 USA (FCC) and Canada (IC) .................... 16 ANNEX Annex A: ID CPR60-DevBoard Reference Design ............18 === Ende der Liste für T extm arke Note === Page 3 of 22...
Page 4
IDENTIFICATION ID CPR60 1 Safety Instructions ► The device may only be used for the intended purpose designed by for the manufacturer. ► The operation manual should be conveniently kept available at all times for each user. ► Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries.
(COM Interface) and an SPI interface. For data transfer with a host computer the ISOHost mode (polling) is available via the USB, COM and SPI interface. The functionality of the ID CPR60 is based on the well known CPR-family, like the reader module ID CPR74 or the wall-mount reader ID CPR50.10 and is compatible with them mainly.
(see The ID CPR60-DevBoard offers 3 SAM sockets for ID-000 smart cards, 1 smart card connector for full size ID 1 cards and different connectors for the USB, COM and SPI interface. The integrated antenna can be used in combination with the CPR60 to communicate with transponders.
IDENTIFICATION ID CPR60 3 Dimensions The ID CPR60 reader module has been designed for the integration into terminals, printers or handheld devices and so on. Figure 1: Dimension (Top View) Figure 2: Dimension (Side View) Page 7 of 22...
X1 (Connector Type: Hirose DF17(2.5)-80DP-0.5V(57)) is the main connector for power supply, interfaces and control signals. The following table shows the pin-assignment of the connector. Interfaces and functions are described from the ID CPR60 view (an input must be connected to one output or vice versa). Figure 3: Connector X1 At connector X1 four external smart card connectors can be connected.
Page 9
IDENTIFICATION ID CPR60 Standby / Low Power Card Detection Function Remark Function Remark n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. 3,3 V DC Supply 3,3 V DC Supply 3,3 V DC Supply SAM3_ CLK n.c. KCC_CLK (SAM4) n.c. SAM1_I/O n.c.
Page 10
IDENTIFICATION ID CPR60 Function Remark Function Remark Control input for low SAM3_RST nLOW_PWR power card detection 0: low power mod low 1: normal mode KCC_RST (SAM 4) n.c. n.c. n.c. n.c. 5 V DC Supply n.c. n.c. n.c. nRESET Reset Input...
IDENTIFICATION ID CPR60 4.2 Connector ANT The ID CPR60 module is equipped with an connector for an external 50 -antenna. The connection of the external antenna is possible via the U.FL connector „ANT“. ANT: (U.FL) Figure 4: Connection of an external antenna The technical description and hints for building external 50 -antennas can be taken from the application...
IDENTIFICATION ID CPR60 5 Standby / Low Power Card Detection The ID CPR60 offers a standby mode to reduce the power consumption to a minimum. The standby mode Connector X1 can be controlled by the host via input nLOW_PWR (see: The standby mode is activated if input nLOW_PWR is set to low.
IDENTIFICATION ID CPR60 6 Technical Data Tab. 2: Technical data ID CPR60 Dimension (W x H x D) max. 41 mm x 41 mm x 6,5 mm Weight approx. 10 g Operating -25 °C up to +70 °C (-13 °F up to +158 °F)
Page 14
IDENTIFICATION ID CPR60 4 SAM card interfaces Contact Interface (ISO 7816) T=0 and T=1 Protocol, Power Class A, B & C Operating Modes ISOHost Mode (Polling Mode) Europe EN 300 330 EN 300 330 Radio Approval FCC - Title 47 CFR Part 15...
UKCA Declaration of Conformity Hereby FEIG ELECTRONIC GmbH declares that the radio equipment type ID CPR60 is in compliance with Directive No. 1206 Radio Equipment Regulations 2017. The full text of the UKCA declaration of conformity is available at the following internet address: https://www.feig.de/en/service/ukca-declarations-of-conformity/...
Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. Installation with FCC / IC Approval: The reader module was tested according to the standard FCC - Title 47 CFR Part 15 §207, $209 and §225...
Page 17
IDENTIFICATION ID CPR60 The manufacturer is obliged to test the terminal equipment without RF transmitter, according to the national FCC requirements according to 47 CFR Part 15 Subpart B. For this purpose, the HF transmitter of the reader module must be switched off. The HF transmitter is switched off by the SW command: Transparent...