Page 1
M U LT I E LEM EN T C A R T R I D G E F I LT ER Installation and Operation I n st a l l a t i o n a n d O p er a t i o n USER MANUAL Models: GX400...
TABLE OF CO N T EN T ..IMPORTANT SAFETY INSTRUCTIONS 1. OVERVIEW ..1.1 PRODUCT INFORMATION 1.2 DIMENSIONS ..2. INSTALLATION 3. STARTING THE PUMP AND FILTER SYSTEM ..3.1 BEFORE STARTING THE PUMP 3.2 STARTING PUMP 3.3 OPERATION 4.
IMPORTANT SAFETY INSTRUCTIONS THESE OPERATING INSTRUCTIONS CONTAIN IMPORTANT INFORMATION ON THE SAFE, PROPER, AND ECONOMICAL OPERATION OF THIS SWIMMING POOL APPLIANCE. STRICT OBSERVATION OF THE OPERATING INSTRUCTIONS WILL HELP TO AVOID DANGERS, REDUCE REPAIR COSTS, AND SHUTDOWN TIMES AND INCREASE THE RELIABILITY AND WORKING LIFE OF THE PRODUCT. Failure to follow the instructions in this manual may result in serious adverse health effects or even serious or fatal injury.
R E A D UN D ER S TA N D AND F O LLO W ALL S A FE T Y AND O P ER AT I O N : Do not operate the filter until you have read and understand clearly all the operating instructions and warning messages for all equipment that is a part of the pool circulating system.
1 . 1 PR O D U CT IN FO R M AT I O N EFFECTIVE FITRATION DESIGN FLOW RATE Model AREA Residential Commercial FT² M² GX430 39.97 [ Filter rate for commercial use at 0.375 GPM/ft². Recommend Flow Rate for 2” piping is 90 x 150 GPM ] ≤...
Air Relief valve Pressure gauge Handle Clamp Inlet Outlet Bottom Body REQUIRED CLEARANCE “B” side “C” above MODEL 18.1 ICF430 18.89 40.7 103.5 3. STARTING THE PUMP AND FILTER SYSTEM 3.1 BEFORE STARTING THE PUMP 1. Use ONLY GX system components; Clamp unit doing assembly, metal-reinforced seal. Non-tighten clamp components may fail in use and cause explosive component separation.
2. Close the filter drain. Note: drain plug requires an O ring seal. Sealing O ring Drain Plug Figure 2 3. Open all system valves to allow water from the pool to the filtration system and from the filter to return to the pool.
3. Monitor the pressure from time to time, when the pressure reading is over the Clean Filter arrow, follow step 4.2 to clean filter cartridge elements. R ep l a ce a n ew f i l t er c a r t r i d g e e l em en t . You should replace a new filter cartridge element: 1.
4 . 4 . 4 VACU U M I N G PO O L Vacuuming can be performed directly into the filter whenever needed. Clean cartridges after vacuuming if required. 4 . 5 R EMO V I N G T H E AI R R ELI EF VA LV E The filter comes with a preinstalled manual air relief valve.
5. WINTERIZING FILTER In areas where sub-freezing temperatures can be expected, the filter should be drained to protect the filter from damage. 1. Follow the steps in”Filter disassemble instruction” to remove and clean the cartridge. 2. Reinstall the cartidge in the filter. 3.
7. SPARE PART LIST Key No. Description Part No. 550178232 Handle Air relief valve 111040077 O-ring d14.3×2.5 111040078 O-ring d6×3.5 550178233 Air relief valve 117038519 Pressure gauge 60psi , plastic casing 111040079 O-ring d50×5 111000048 O-ring D76 x d65.6 x 5 430138225 Handle for the lid 550058225...
It is not transferable to anyone who subsequently purchases the product from you. It excludes all expendable parts. During the warranty period, Reltech authorized reseller will repair or replace defective parts with new parts or, at the option of Reltech , serviceable used parts that are equivalent or superior to new parts in performance.
Page 14
POOL EQUIPMENT RELTECH AUSTRALIA PTY LTD 43-45 KYLTA RD, WEST HEIDELBERG VIC 3081 03 94593838 EM: office@reltech.com.au WEB: www.reltech.com.au www.reltech.com.au...