Summary of Contents for HYXIPOWER HYX-EA1000 Series
Page 1
HYX-EA1000 Series Portable Power Station User Manual Before using the product, please read this manual carefully and keep it properly Zhejiang Hyxi Technology Co., Ltd. for future reference!
Page 2
Notice to Customers Dear customer, thank you for choosing our products and services. Before using the product, please read this user manual carefully to have a clear understanding based on which you can use the product successfully. Once you use this product, it is considered that you have understood, approved, and accepted all the terms and service contents specified in the user manual.
Contents I. Safety Guidelines ....................1 Safety precautions ....................1 Disposal ........................2 II. Product Introduction ..................3 1. Product appearance ....................3 2. UI …………………………………………………………………………………………………………………………………4 3. Specifications ......................5 III. Use of the product ................... 7 1. Use of the product ...................... 7 2.
I. Safety Guidelines Safety precautions 1. Do not immerse the product into liquid or water, or make it hygroscopic. If there is dirt on the surface or interface of the product, use a dry cloth to clean it. 2. It is strictly forbidden to put the product near a heat source, combustion source, or heating furnace to prevent the hazards because the product becomes overheated.
10. If the product catches fire by accident, it is recommended that you use extinguishing devices in the following order: sand, fire blanket, dry powder, and carbon dioxide extinguisher. 11. If the product is seriously damaged, do not touch the exposed cell. For safety, place the product in an open area, away from combustibles and people, and then retire it in accordance with local laws and regulations.
II. Product Introduction This product is a portable power station, with a battery capacity of 998 Wh and rated output power of 1000 W. It has built-in high-rate lithium iron phosphate (LFP) power cells with excellent safety. This product provides the bidirectional inverter function. The AC output is a pure sine wave of voltage, ranging from 220 V to 240 V (50/60 Hz), and the rated output power is 1000 W.
Page 7
2. UI Alarm EPS function High temperature protection Charging gear Low temperature protection Overload protection AC input Battery percentage AC output startup AC input mode Fan operation Remaining discharging / charging time DC output startup Input power USB output startup Output power For more information about fault display and handling, refer to Chapter 4.
3. Specifications Basic specifications 38.0 × 21.4 × 26.4 cm/15.0 × 8.4 × 10.4 in Net weight 12 kg/26.5 lbs Size Battery capacity 998 Wh (39000 mAh/25.6 V) Cycle life 4000 times Rated power 1000 W, peak power of 1800 W Cell type Lithium iron phosphate battery...
Page 9
Use conditions °C °C °F °F Operating temperature to 45 to 113 °C °C °F °F Charging temperature to 40 to 104 Working environment humidity 20% to 90% RH (no condensation) °C °C °F °F Storage temperature to 45 to 113 Storage environment humidity <...
III. Use of the product 1. Use of the product Power-on/off The main power switch controls the product to power on or power off. Press the main power switch to power on the product. In power-on state, long-press the main power switch for 2 seconds to power off the product. In power-on state, press the main power switch to make the display switch between on and off states.
AC output Turn on the main power supply. Press the AC output switch. After that, the 230 V AC output is turned on, the AC socket starts to output power supply, and the AC switch indicator is turned on. Press the AC output switch again. After that, the 230 V AC output is turned off, and the AC output switch indicator is turned off.
Note: When the AC input is connected to the mains, if you do not need to use the AC output, please turn off the AC output switch, otherwise it will reduce the AC charging power. For the AC charging indicators, refer to the following table. Pressing sequence Screen display Variable charging...
charging power fluctuates during photovoltaic charging. This product supports charging through the same type of solar panels. The company shall not bear the responsibility for any damage caused by improper operations or using different types of solar panels. 5. EPS function This mode is enabled by default.
6. Long-term backup power mode The product can be connected to the mains for a long period of time. The built-in intelligent system of the product automatically manages charging and discharging. If the product is not used for a long period of time, to meet the power backup requirement, the AC input port can always be connected to the mains, and it is intelligently determined that the battery is automatically recharged every 45 days.
IV. Fault Display and Handling Warning icon Fault type Handling Remarks Flashing: The rated The load exceeds the load capacity AC output power is exceeded of the product. termination and but no protection is 1. When the fault occurs, press the overload performed.
Page 16
The USB power Check whether the load capacity of USB output supply is faulty, and the product is exceeded. termination. the output is 1. When the fault occurs, press the abnormal. USB output switch to clear the alarm. 2. If the alarm indicates that the load capacity of the product is exceeded, reduce the load and press the USB output switch again to...
Page 17
If the two It is detected that the power device Output indicators flash at temperature is too low. Wait the termination. the same time, it temperature to change to normal indicates a low before using the product again. temperature alarm of the power device.
V. Package Contents Power station AC charging cable Car charging cable User manual VI. Maintenance 1. It is recommended that the product be in long-term backup power mode. If the product needs to be stored for a long period of time, charge and discharge it once every three months (that is, first discharge the product to 30% of the full capacity, and then charge the product to 60%.) 2.
providing services or charge the cost of parts and services in the following circumstances: 1. The appearance of the product is damaged after use. 2. Unauthorized disassembly and maintenance of non-professionals. 3. Performance problems caused by human factors. 4. Damage caused by natural disasters, lightning strikes, accidents, and other irresistible factors.
Page 20
This product complies with the European Low Voltage Directive 2014/35/EU and EMC Directive 2014/30/EU. WEEE Directive–2012/19/EU The product this manual refers to is covered by the Waste Electrical & Electronic Equipment (WEEE) Directive and must be disposed of in a responsible manner. Battery Directive-2013/56/EC Battery in the product complies with the European Battery Directive 2013/56/EC.