OL-U SERIES Contents Introduction to the user manual ..............................4 Meaning of the symbols used ..............................4 Products overview ..................................4 Installation instructions ................................5 Configuration and commissioning ............................. 5 KNX Secure .................................... 5 General parameters .................................. 6 General settings ..................................6 Buttons configuration ................................
Page 3
We therefore cannot accept any liability for this. Any neces- sary corrections will be incorporated into newer versions of this manual. Eelectron S.p.A. Via Claudio Monteverdi 6, I-20025 Legnano (MI),Italia Tel +39 0331.500802 info@eelectron.com OL-U_UM_EN M E M B E R...
KNX functions. A freely configurable RGB Led bar is also available for dis- • MO04A01KNX-X: MultiSensor 4 Buttons | 4 ch - RGB Swip- playing states or other quantities available on the KNX bus. • 32 logic blocks are available to implement simple expres-...
“safe” device. For this purpose, the camera is available as a QR the ETS® (Engineering Tool Software). For the configuration of Code Reader or the code must be entered manually the device parameters the corresponding application program or the whole eelectron® product database must be loaded in the 92 mm 25 mm ETS® program.
Humidity sensor disabled / enabled power-up Versions HO04A01KNX, MO04A01KNX-X and MO04L02KNX-X in- Through this parameter it is possible to set the telegram transmission clude a humidity sensor to perform ambient humidity measurement delay after switch-on by selecting the time beyond which the device is with a tolerance of ±2% between 0% and 90% RH.
OL-U SERIES Display none: no function associated bus value: it enables the CO “<LED Quality> Off / On” and “<LED Quality> Color” for sending the activation telegram and set the color of the LED. LEDs For temperature, humidity CO2 and VOC indicators, are set thresholds with colour corresponding to values under or above threshold.
OL-U SERIES KNX PARAMETER SETTINGS Economy mode never switch OFF, 1 to 15 min none When this option is enabled, the device enters economy mode after a configurable time. It’s possible to configure a behaviour for each LED bus value LED Cooling in the front panel when it enters Economy mode. When the device en- cooling (internal management) ters Economy mode, the device is awakened by the touching Swiper none: no function associated...
OL-U SERIES HVAC remote control Object enable disabled / enabled This parameter enables the object “<Special Button - x> Enable Ob- Communication objects involved: ject” of the relative special button. Initial enable state disabled / enabled “<Special button> HVAC Control Feedback” 1 byte This parameter defines whether to have the object “<Special Button - “<Special button>...
Page 10
OL-U SERIES SLOW Multiple % values from left to right In General parameters it’s possible to set the configuration and Increase direction from right to left average of algorithm for this function. It defines the direction to follow for increasing the percentage. KNX PARAMETER SETTINGS 0 ... 8 for thermostat Main button (0=last used) 0 ... 16 for switch prefer resolution over accuracy Configuration normal...
Page 11
OL-U SERIES To avoid a wrong reading of the swipe direction, Send R+G+B do not go beyond the action area indicated in the This parameter enables the objects figure • “<Swiper-Slow> Red” • “<Swiper-Slow> Green” Communication objects involved in each function: •...
OL-U SERIES TAP LEFT, TAP RIGHT, DOUBLE TAP L / R “<LED x> Color Change Index - OFF” 1 Byte CW “<LED x> Color Change Index - ON” 1 Byte CW For the devices: SO08L02KNX: Lite Switch 8 Buttons | 16 ch - RGB SO04L02KNX: Lite Switch 4 Buttons | 8 ch - RGB Tap gesture can be associated with both basic and special func- TO04L02KNX: Lite Thermostat 4 Buttons | 8 ch - RGB...
OL-U SERIES 9. Temperature function 1 / 2 This parameter defines the delay in sending the “output” objects on the BUS, applied after the calculation Please refer to the “Thermostat and additional probe” user ma- index to RGB nual. Conversion RGB to index index to RGB: in this mode, writing a value (0-13) on the 1 byte CW 10.