Eelectron HO04A01KNX User Manual

Eelectron HO04A01KNX User Manual

Thermostat / humidistat 4 buttons,8 ch - rgb swiper, thermostat 4 buttons,8 ch - rgb swiper, multisensor 4 buttons,4 ch - rgb swiper, switch 8 buttons,16 ch - rgb swiper, lite switch 8 buttons,16 ch - rgb, lite switch 4 buttons,8 ch - rgb, thermostat 8 bu
Hide thumbs Also See for HO04A01KNX:

Advertisement

Quick Links

HO04A01KNX
TO04A01KNX
MO04A01KNX
SO08A01KNX
SO08L02KNX
SO04L02KNX
TO04L02KNX
MO04L02KNX
Thermostat / Humidistat 4 Buttons | 8 ch - RGB Swiper
Thermostat 4 Buttons | 8 ch - RGB Swiper
MultiSensor 4 Buttons | 4 ch - RGB Swiper
Switch 8 Buttons | 16 ch - RGB Swiper
Lite Switch 8 Buttons | 16 ch - RGB
Lite Switch 4 Buttons | 8 ch - RGB
Thermostat 8 Buttons | 16 ch - RGB
Lite Multisensor 4 Buttons | 4 ch - RGB
USER MANUAL
Translation of the original instructions
Version: 1.0
Date: 19/Apr/2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HO04A01KNX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eelectron HO04A01KNX

  • Page 1 HO04A01KNX Thermostat / Humidistat 4 Buttons | 8 ch - RGB Swiper TO04A01KNX Thermostat 4 Buttons | 8 ch - RGB Swiper MO04A01KNX MultiSensor 4 Buttons | 4 ch - RGB Swiper SO08A01KNX Switch 8 Buttons | 16 ch - RGB Swiper...
  • Page 2: Table Of Contents

    OL-U SERIES Contents Introduction to the user manual ..............................4 Meaning of the symbols used ..............................4 Products overview ..................................4 Installation instructions ................................5 Configuration and commissioning ............................. 5 KNX Secure .................................... 5 General parameters .................................. 6 General settings ..................................6 Buttons configuration ................................
  • Page 3 We therefore cannot accept any liability for this. Any necessary corrections will be incorporated into newer ver- sions of this manual. Eelectron S.p.A. Via Claudio Monteverdi 6, I-20025 Legnano (MI),Italia Tel +39 0331.500802 info@eelectron.com OL-U_UM_EN M E M B E R...
  • Page 4: Introduction To The User Manual

    • TO04A01KNX: Thermostat 4 Buttons | 8 ch - RGB Swiper command and control functions. • HO04A01KNX: Thermostat / Humidistat 4 Buttons | 8 ch - • The swiper consists of a capacitive bar with swipe function RGB Swiper for the implementation of programmable KNX functions.
  • Page 5: Installation Instructions

    “safe” device. For this purpose, the camera is available as a QR the ETS® (Engineering Tool Software). For the configuration of Code Reader or the code must be entered manually the device parameters the corresponding application program or the whole eelectron® product database must be loaded in the 92 mm 25 mm ETS® program.
  • Page 6: General Parameters

    KNX sensor. At the end of ETS programming, the device behaves as it did after it For devices TO04A01KNX HO04A01KNX and TO04L02KNX the CO2 was switched on. is a logic function that refers to a knx external sensor. For MO04A01K-...
  • Page 7: Display

    VOC: display shows the measure of VOC (KNX sensor) speed correspond to fan speed 2. [1] values are in °C or °F [2] values are in % - only for HO04A01KNX, MO04A01KNX, Allow fan speed 2: the LED is on when the actual speed MO04L02KNX correspond to fan speed 2.
  • Page 8: Front Panel

    OL-U SERIES KNX PARAMETER SETTINGS Economy mode never switch OFF, 1 to 15 min none When this option is enabled, the device enters economy mode after a configurable time. It’s possible to configure a behaviour for each LED bus value LED Cooling in the front panel when it enters Economy mode. When the device en- cooling (internal management) ters Economy mode, the device is awakened by the touching Swiper none: no function associated...
  • Page 9: Swiper

    OL-U SERIES HVAC remote control Object enable disabled / enabled This parameter enables the object “<Special Button - x> Enable Ob- Communication objects involved: ject” of the relative special button. Initial enable state disabled / enabled “<Special button> HVAC Control Feedback” 1 byte This parameter defines whether to have the object “<Special Button - “<Special button>...
  • Page 10 OL-U SERIES SLOW Multiple % values from left to right In General parameters it’s possible to set the configuration and Increase direction from right to left average of algorithm for this function. It defines the direction to follow for increasing the percentage. KNX PARAMETER SETTINGS 0 ... 8 for thermostat Main button (0=last used) 0 ... 16 for switch prefer resolution over accuracy Configuration normal...
  • Page 11 OL-U SERIES To avoid a wrong reading of the swipe direction, Send R+G+B do not go beyond the action area indicated in the This parameter enables the objects figure • “<Swiper-Slow> Red” • “<Swiper-Slow> Green” Communication objects involved in each function: •...
  • Page 12: Leds

    OL-U SERIES TAP LEFT, TAP RIGHT, DOUBLE TAP L / R For the devices: SO08L02KNX: Lite Switch 8 Buttons | 16 ch - RGB SO04L02KNX: Lite Switch 4 Buttons | 8 ch - RGB TO04L02KNX: Lite Thermostat 4 Buttons | 8 ch - RGB MO04L02KNX: Lite MultiSensor 4 Buttons | 4 ch - RGB the LEDs are only in white color.
  • Page 13: Humidistat

    OL-U SERIES 10. Humidistat index to RGB Conversion RGB to index Please refer to the “Humidistat” user manual. index to RGB: in this mode, writing a value (0-13) on the 1 byte CW object "<Logic x> Index", you can send the RGB color corresponding to the CRT objects "<Logic x>...