Aimco Signature SPT Series Manual

20v cordless transducerized tools

Advertisement

Quick Links

SPT Series 20V Cordless
Transducerized Tools
10000 SE Pine St.
Portland, Oregon 97216
Phone: 1-800-852-1368
www.aimco-global.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Signature SPT Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aimco Signature SPT Series

  • Page 1 SPT Series 20V Cordless Transducerized Tools 10000 SE Pine St. Portland, Oregon 97216 Phone: 1-800-852-1368 www.aimco-global.com...
  • Page 2: Table Of Contents

    5.18 Group Count Setting..27 Charging the Battery Pack ..Battery Charger Lamp Indications ..Specifications ... . www.aimco-global.com - 2 -...
  • Page 3: Safety Guidelines

    • When servicing an AIMCO Signature • Use safety equipment. Always wear Series tool it is important to use AIM- eye protection. Dust mask, non-skid CO Signature Series parts and all work...
  • Page 4 This product has been carefully inspected prior to leaving the factory. It should provide you with years of satisfying service under normal operating conditions. Do not, however, force the tool to perform outside its design parameters. Such usage will void the warranty. www.aimco-global.com - 4 -...
  • Page 5: Functions

    To switch tool back to The LED light will remain on for 5 forward operation, simply press the seconds, then shut off. button again and the tool is back in forward operation. 2. LED Light The bright LED illuminates dark areas. www.aimco-global.com - 5 -...
  • Page 6 7. Mini USB Port This port is for checking motor data. WARNING: DO NOT CONNECT TO THE TOOL USB MINI-B PORT WITH ANYTHING OTHER THAN AN SPT-USBD DONGLE. SEVERE DAMAGE TO THE CONNECTED PC WILL RESULT www.aimco-global.com - 6 -...
  • Page 7: Assembly

    Good practice is to perform periodic audits of the application. Auditor™ Torque Wrenches or Rotary Transducers are ideally suited for this. www.aimco-global.com - 7 -...
  • Page 8 3. Use an open end wrench and the supplied adjustment wrench to tighten the nut by turning in opposite direction to complete angle adjustment. www.aimco-global.com - 8 -...
  • Page 9: Display Screen Overview

    Programming Keys Pistol Tools Angle Tools LED Indicators LED Indicators Programming Keys The functions of the Programming keys are shown on the display screen. LED Indicators Reverse Low Battery Warning Change Battery www.aimco-global.com - 9 -...
  • Page 10: Display Screen Walkthrough

    Threshold Torque Enter or confirm Switch to the last screen or change value Angle High Limit Confirm the setting Angle Low Limit Press or pull the trigger to return to the Run screen Tightening Direction A. Clockwise B. Counter-clockwise Group Count www.aimco-global.com - 10 -...
  • Page 11: Tool Operation

    3. Upper secondary display (left): target torque value / target angle value. LED Indicators Reverse Low Battery Warning Change Battery Screw number Target Torque/ tightened/Group Target Angle count Sequence of the P-Step Actual tightening torque Unit of torque www.aimco-global.com - 11 -...
  • Page 12: Setting Screen

    Press to enter the password screen. 5.3 Entering the Password The primary display shows the 4-digit password, and each digit is adjustable from 0 to 9. 3. Press to move the cursor to the number wish to be adjusted. 4. Press to increase the number, up to 9. 5. Press to decrease the number, down to 0. 6. Press to confirm. If the password is valid, the display will be unlocked and continue to settings that can be adjusted. If the password in invalid, the display will return to the setting screen as 4.2 shown. Note: To reset the password, the NPT software is required. www.aimco-global.com - 12 -...
  • Page 13: Setting Up The P-Step Sequence

    Note: First digit cannot be 0. 3. Press to move the cursor to the next digit. 4. Press to confirm and save, and press . The screen background color turns to black. 5. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 13 -...
  • Page 14: P-Step Configuration

    2. Press to select bigger number 3. Press to select smaller number 4. Press to confirm and save, and press . The screen background color turns to black. 5. Press to go to next setting, or press back to last setting, or press return to the run screen. www.aimco-global.com - 14 -...
  • Page 15: Mode Settings - Torque Or Angle

    2. Press to move the cursor to set the tightening mode to Torque or Angle 3. Press to confirm and save, and press . The screen background color turns to black. 4. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 15 -...
  • Page 16: Setting Target Torque

    Press and hold to decrease the number rapidly. 4. Press to confirm and save, and press . The screen background color turns to black. 5. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 16 -...
  • Page 17: Setting Target Angle

    When the number goes up to 9, it returns to 0. 3. Press to move the cursor to the right for the number position you want to adjust. 4. Press to confirm and save, and press . The screen background color turns to black. 5. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 17 -...
  • Page 18: Shift Down Torque Setting

    Press and hold to decrease the number rapidly. 4. Press to confirm and save, and press . The screen background color turns to black. 5. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 18 -...
  • Page 19: Shift Down Speed Setting

    Press and hold to decrease the number rapidly. 4. Press to confirm and save, and press . The screen background color turns to black. 5. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 19 -...
  • Page 20: Free Speed Setting

    Press and hold to decrease the number rapidly. 4. Press to confirm and save, and press . The screen background color turns to black. 5. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 20 -...
  • Page 21: Torque High Limit Setting

    Press and hold to decrease the number rapidly. 4. Press to confirm and save, and press . The screen background color turns to black. 5. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 21 -...
  • Page 22: Torque Low Limit Setting

    Press and hold to decrease the number rapidly. 4. Press to confirm and save, and press . The screen background color turns to black. 5. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 22 -...
  • Page 23: Threshold Torque Setting

    Press and hold to decrease the number rapidly. 4. Press to confirm and save, and press . The screen background color turns to black. 5. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 23 -...
  • Page 24: Angle High Limit Setting

    4. Press to confirm and save, and press . The screen background color turns to black. 5. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 24 -...
  • Page 25: Angle Low Limit Setting

    4. Press to confirm and save, and press . The screen background color turns to black. 5. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 25 -...
  • Page 26: Tightening Direction Setting

    3. Press to confirm and save, and press . The screen background color turns to black. 4. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 26 -...
  • Page 27: Group Count Setting

    Press and hold to decrease the number rapidly. 4. Press to confirm and save, and press . The screen background color turns to black. 5. Press to go to next setting, or press back to last setting, or press to return to the run screen. www.aimco-global.com - 27 -...
  • Page 28: Charging The Battery Pack

    NOTE: Remove the battery pack when the tool is not in use, to avoid damage to the battery pack that can reduce the service life. Recharge the battery pack once every 6 months even if the battery is not in use. www.aimco-global.com - 28 -...
  • Page 29: Battery Charger Lamp Indications

    The battery and the charger are not connected. If the yellow lit still on after trying re-attach the battery, consult an authorized dealer. Green Flashing Light Now start charging Green Flashing Light Battery is approximately 50% charged. Green Flashing Light Battery is approximately 80% charged. Green Light Charging is complete. (Fully charged.) www.aimco-global.com - 29 -...
  • Page 30: Specifications

    1.68 kg (3.7 lb) 2.16 kg (4.77 lb) Battery Type (Li-Ion) 2.5Ah 5.0Ah 2.5Ah 5.0Ah 5.0Ah Noise Level dB(A) < 75 < 75 < 75 Torque Accuracy Meets ISO 5393 Cmk >1.67 at ± 7.5% tolerance. www.aimco-global.com - 30 -...
  • Page 31 2.16 kg (4.77 lb) 2.16 kg (4.77 lb) 2.16 kg (4.77 lb) Battery Type (Li-Ion) 5.0Ah 5.0Ah 5.0Ah Noise Level dB(A) < 75 < 75 < 75 Torque Accuracy Meets ISO 5393 Cmk >1.67 at ± 7.5% tolerance. www.aimco-global.com - 31 -...
  • Page 32 CORPORATE HEADQUARTERS 10000 SE Pine Street Portland, Oregon 97216 Phone: (503) 254–6600 Toll Free: 1-800-852-1368 WWW.AIMCO-GLOBAL.COM AIMCO CORPORATION DE MEXICO SA DE CV Ave. Cristobal Colon 14529 Chihuahua, Chihuahua. 31125 Mexico Phone: (01-614) 380-1010 Fax: (01-614) 380-1019 LIT-MAN259 Rev. 08-09-24...

Table of Contents