Summary of Contents for Rangemaster GEO Intense GEO4TIDBF
Page 1
GEO Intense 4 in1 Hot Tap Installation Guide Please read these instructions carefully before installation or use and retain for future reference. You must install the tap and filter before the boiler. We have a policy of continued product and quality development and improvement. Accordingly we reserve the right to amend the specification at any time.
Page 2
⚠ A technical or safety An information point or tip for A service, maintenance consideration or warning of installation or usage. or care consideration. hazardous situation with regard to life and property. Using the product Using the product Using the product Using the product Thank you for choosing this product.
Page 3
Your tap can dispense Your tap can dispense 4 4 4 4 types of water: Your tap can dispense Your tap can dispense types of water: types of water: types of water: Cold (filtered) water – – – – This is delivered when the left side handle is rotated backwards up to a maximum Cold (filtered) water Cold (filtered) water Cold (filtered) water...
Page 4
In the unlikely event that you should experience any defect in the materials or workmanship of your new Rangemaster 4 in 1 hot mixer tap within FIVE years of purchase, the purchaser’s sole remedy shall be the replacement (at the manufacturer’s discretion) of all or any part of the product that is defective. All working parts and valves are guaranteed for a period of FIVE years from purchase.
Page 5
Tap installation Tap installation Tap installation Tap installation Important Technical Data Important Technical Data Important Technical Data Important Technical Data Minimum operating pressure (hot): 0.5 bar Minimum operating pressure (cold): 1.5 bar Maximum operating pressure: 5.5 bar* Maximum domestic hot water temperature: 70°C* Flow characteristics: Domestic Hot, Cold &...
Page 6
Installation Preparation Installation Preparation Installation Preparation Installation Preparation ⚠ You must install the mixertap and filter before the boiler. ⚠ Before installing the new mixer it is essential that you thoroughly flush through the supply pipes flush through the supply pipes in order flush through the supply pipes flush through the supply pipes to remove any remaining solder, swarf or impurities from your system.
Page 7
Parts and Contents Parts and Contents Parts and Contents Parts and Contents Key Description Description Description Description Mixer tap Base plinth Base plinth seal Sink or worktop (max. 50mm) White triangular plate (for use with steel sinks only) Lower gasket Metal horseshoe Fixing stud Fixing nut...
Page 8
Install the tap: Install the tap: Install the tap: Install the tap: This diagram shows the view of the base of the tap (A1) with the 98°C water handle to the left of the body. ⚠ YOU MUST CAREFULLY ACKNOWLEDGE THE INLETS AND OUTLETS AS SHOWN...
Page 9
15. Arrange and install the domestic cold in isolation valve (G1) and a stub of 15mm pipe (G4) using 15mm compression nut (G3) and olive (G2). 16. Fix the ½” x ½” x 3/4” isolating tee valve (G7) to the cold water feed pipe (G4) using 15mm compression nut (G5) and olive (G6).
Page 10
Meadow Lane, Long Eaton, Nottingham, NG10 2GD, England Trade Enquiries: +44 (0)115 946 4000 Consumer Enquiries: +44 (0)1926 457628 E-mail: consumers@agarangemaster.co.uk www.rangemaster.co.uk 06/2022 Please leave these instructions for your customer...
Page 11
PROBOIL.2X User & Installation Guide www.proboil.co.uk See top of boiler unit for contact details Please read these instructions carefully before installation or use and retain for future reference. You must install the tap and filter before the boiler. We have a policy of continued product and quality development and improvement.
1 1 1 1 PROBOIL.2X user guide PROBOIL.2X user guide PROBOIL.2X user guide PROBOIL.2X user guide 1.1 Important safety and usage considerations Important safety and usage considerations: : : : Important safety and usage considerations Important safety and usage considerations Throughout this guide, the following symbols are used to highlight key points or safety considerations.
⚠ WARNING If the appliance is to be handed over to someone else for use, all documentation and information should also be given. ⚠ WARNING This appliance must be installed respecting local plumbing and electrical regulations. ⚠ WARNING This appliance must use only genuine parts and accessories and sundry consumables.
⚠ WARNING This appliance is not intended to be operated by means of an external timer or separate remote control system. ⚠ WARNING unless attached to a modern consumer unit with RCD protection we recommend installing a local RCD protection device in the socket being used by the appliance. 1.1.3 Intended purpose: ⚠...
⚠ For safety regulations the plug or means of disconnection must always be accessible after installation. ⚠ Do not use any water jet or steam near this appliance. ⚠ Always ensure an airgap of at least 10mm around the appliance and that any closed cabinet has sufficient airflow.
To dispense hot water To dispense hot water To dispense hot water To dispense hot water (Model may vary) (Model may vary) (Model may vary) (Model may vary): : : : 1) Fully push the 98° water lever down to bypass the child lock and simultaneously turn the handle forwards, the further the lever is turned the greater the flow.
⚠ WARNING If you are not using the product and leaving it unattended for a period longer than 1 week you should turn the boiler into standby mode (see using the product section), do not turn off the power at the mains socket as this will reset the filter counter. You may also consider closing your mains stop cock to prevent flood damage from any of the water using appliances in your household.
1.2 Using the product: Using the product: Using the product: Using the product: 1.2.1 Boiler screen and interface: The boiler uses a touch screen interface to both display and change the status of the boiler. Temperature adjust: Touch sensitive & keys lower and raise the boilers maximum target temperature between a selection of pre-set values 75, 85, 90, 95, 96, 97- 98°C White colour, constantly illuminated when unit is not in standby mode, the boiler will...
Page 20
Heating indicator: Displays when the boiler is in a heating stage indicating the boiler is re-heating the water inside to achieve the pre-set target temperature. It is normal for the heating indicator to switch off before the target temperature is achieved as remaining heat inside the unit is still to disperse fully into the stored water.
1.2.2 Filter replacement guide: The product is supplied with a filter specifically designed to both improve the taste and clarity of the water but also to assist protecting the boiler from contaminants and scale. Each filter has a maximum life span of 6 months or 1000 litres (apx. 2800 cups), whichever occurs first. Regardless of the amount of usage it is required for you to replace the filter on schedule for reasons of product protections, hygiene and maintaining your warranty.
Page 22
6. Place a bowl (or similar) under the filter cartridge and pipes to catch any retained water in the system. 7. Take note of the direction (orientation) of the filter installed. The “FLOW->” indication on the label shows the direction of water flow from inlet to outlet.
Page 23
10. Push the “inlet” flexible blue pipe firmly and fully into the new filter cartridge inlet. Hold the filter and pull the pipe away from the filter to check it has inserted correctly. If the fit is too tight to push home the pipe fully add a single drop of dish soap onto the end of the pipe and push firmly.
Page 24
14. Push the “outlet” flexible blue pipe firmly and fully into the new filter cartridge outlet. Hold the filter and pull the pipe away from the filter to check it has inserted correctly. If the fit is too tight to push home the pipe fully add a single drop of dish soap onto the end of the pipe and push firmly.
Page 25
18. Wait for the boiler to show “READY” before use. 19. If the used filter cartridge is applicable for our recycling scheme please leave it upwards in the sink to drain any residual water from inside before packing and returning it as instructed. PROBOIL.2X user &...
Descaling the system 1.2.3 PROBOIL PROBOIL2X like all other appliances that use hot water can become coated with limescale over time, replacing your filter frequently will help delay this. Depending on the frequency of your usage pattern and the harder the water in your area, the quicker you should expect the limescale to build and therefore will need to be cleaned and descaled.
The water water tank within the PROBOIL.2X boiler: tank within the PROBOIL.2X boiler: water water tank within the PROBOIL.2X boiler: tank within the PROBOIL.2X boiler: The filter system provided with PROBOIL will help to prevent of the calcification (scaling) of the boiler. However it will be required from time to time that the PROBOIL will need to be descaled, drained and refilled to ensure the maximum energy efficiency and service life from the product especially in hard water areas.
Page 28
5) Firmly pull the silicone rubber high temperature output hose (K) off from the red outlet wing nut (J) connector. 6) Lift up then pull the boiler to unhook the boiler from its keyhole slots away from the wall it is mounted on. 7) Unscrew and detach the red outlet wing nut (J) connector from the top of the boiler (C).
Page 29
15. Reconnect all the removed parts from the boiler in the reverse order listed above. (do not use a spanner or overtighten connectors G or J) 16. Turn on the 98°C tap handle on slowly, keep the handle on until you see water exit the spout of the tap then turn it off immediately.
Cleaning and sterilising the PROBOIL system internal tank 1.2.4 ⚠ Periodically it is prudent to clean the PROBOIL.2X boiler this might because the boiler has been left switched off for long periods, possible contamination from dirt or debris, unwanted taste. When you clean the boiler we recommend you follow the descaling procedure first.
Page 31
9) Remove the inlet meshed filter seal (H) from the boiler inlet (B) or inlet adaptor (G), rinse the washer in cold water, and use a toothbrush to clean any debris from it. If meshed seal (H) is compressed inside inlet (B) or adaptor (G) then use a cocktail stick (or similar) to remove it.
Page 32
16. Wait for the PROBOIL.2X unit to display “READY” onscreen 17. Take note of the time and wait for no longer than a further 10 minutes maximum for the sterilising liquid to work. It is normal for an odour to be present during this time. 18.
1.3 Troubleshooting: Troubleshooting: Troubleshooting: Troubleshooting: ⚠ If you suspect your product has a fault you can use the guide below or if you are unsure about your issue you should isolate both the mains power and water and contact the service number on top of the boiler. 1.3.1 Boiler screen and interface: Issue description: Possible issue &...
1.3.3 Water dripping from the spout end when the handle is in the off position: Issue description: Possible issue & solutions: Water is dripping (continuously from the The hot water on/off valve is leaking, to confirm the fault: centre channel of the spout end aerator). 1) Turn the boiler into standby mode, press and hold the key for 1.5 seconds to activate.
It is normal for a short delay after the handle is turned on for 98°C water does not start the instant the 98°C water to start flowing as the tap empties partly after each use. handle is turned on. The spout aerator may be blocked or calcified, see “descaling- ⚠...
1.4 Warranty terms and Warranty terms and Warranty terms and Warranty terms and conditions conditions conditions: : : : conditions If you believe your product has developed a fault, firstly isolate the product from the mains power and water then please review the troubleshooting section of this guide, should this not resolve your issue then please contact the service agent (details shown on the top of the boiler).
2 2 2 2 PROBOIL.2X installer guide PROBOIL.2X installer guide PROBOIL.2X installer guide PROBOIL.2X installer guide 2.1 About the PROBOIL.2X water heater: About the PROBOIL.2X water heater: About the PROBOIL.2X water heater: About the PROBOIL.2X water heater: 2.1.1 Important technical data: Boiler: Boiler: Boiler:...
This symbol on the product(s) and / or accompanying documents means that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling, please take this product(s) to designated collection points where it will be accepted free of charge. Alternatively, in some countries you may be able to return your products to your local retailer upon purchase of an equivalent new product.
2.1.2 Parts and contents: This carton will contain the following parts, please check all are present and free from transportation damage before commencing installation. Qty. Description Key Number Spares part code Drawing / image PROBOIL.2X boiler unit Complete with sealing caps Mains power cable ASPT1180-D1 ¼”...
2.2 Installation: Installation: Installation: Installation: 2.2.1 Installation preparation Preparing yourself to install the product is an important part of the installation and will help you overall to improve the quality and speed of the installation of this product. 1) Turn off the hot and cold domestic water supplies or isolate the both feeds with local isolation (service) valves.
About the product About the product: : : : About the product About the product Date of installation Serial number (taken from top of boiler or data plate) All parts are present, correct and undamaged Install location Install location: : : : Install location Install location There is enough physical space to install the boiler and...
2.2.2 Install the tap Installation of the tap will vary from model to model, you must now refer to the separate installation guide supplied with the tap or dispenser at this time. 1) Install the tap as per the model specific guidelines supplied with each tap connect the domestic cold (and hot if applicable) water inputs to the tap.
2.2.3 Install the filter The filter is supplied within the tap package and must be installed after the tap or dispenser. Again, the instructions for installing the filter vary by tap model so you should refer to these separately now. ...
2.2.4 Install the boiler The boiler should be the last section of the product to install, you should already have the tap and filter installed and the cold filtered (1/4” blue tube) water and hot water hose connector to the tap free and ready to connect. ⚠...
Page 45
1. Roughly position the boiler (A) into its final installation location. Check there is sufficient length on the pipes (E & K) to and from the boiler to make connections. Check the power cable (D) will reach the power outlet socket. Check the boiler is accessible to your customer so they can easily disconnect and remove the boiler for maintenance.
Page 46
8. Check that the red 3/8” x 8mm boiler outlet connector (J) has preinserted internally the 3/8” rubber seal (I), an additional seal is supplied, ensure to use only 1 x 3/8” rubber seal in this connection. 9. Screw the red 3/8” x 8mm boiler outlet connector (J) hand tight (do not use a spanner or overtighten as the rubber seal may distort or be damaged) on to the boiler 3/8”...
Page 47
CORRECT 16. Take the silicone outlet tube (K) that carries the 98°C water from the boiler to the tap and rough out the minimum amount of pipe needed to red 3/8” x 8mm boiler outlet connector (J) found on the boiler outlet. Mark the desired minimum pipe length with a permanent pen.
2.2.5 Commissioning and testing You have finished the installation, now please take a few moments to go through the commissioning and testing process, this will ensure the product is working correctly, safely and your customer’s satisfaction. ⚠ WARNING You must not skip this section, we are not liable for any safety or performance issues as a result of not following the step by step installation guide with due care, DO NOT TURN ON THE BOILER UNTIL FULLY FLUSHED.
Need help?
Do you have a question about the GEO Intense GEO4TIDBF and is the answer not in the manual?