  • Page 1 MBa8MP-RAS314 Preliminary User's Manual MBa8MP-RAS314 UM 0003 02.08.2024...
  • Page 2: Table Of Contents

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page i TABLE OF CONTENTS ABOUT THIS MANUAL ....................................6 Copyright and license expenses ............................6 Registered trademarks ................................6 Disclaimer ......................................6 Imprint ......................................6 Tips on safety ....................................7 Symbols and typographic conventions ..........................
  • Page 3 Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page ii CLIMATIC AND OPERATIONAL CONDITIONS ........................... 31 Protection against external effects ............................ 31 Reliability and service life ............................... 31 ENVIRONMENT PROTECTION ................................32 RoHS ....................................... 32 ®...
  • Page 4 Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page iii TABLE DIRECTORY Table 1: Terms and conventions ..................................... 7 Table 2: Data interfaces ......................................10 Table 3: Diagnostic and user interfaces ................................10 Table 4: C devices, address mapping on TQMa8MPxL and MBa8MP-RAS314 ..................12 Table 5: Temperature sensor SE97BTP, D1 ...............................
  • Page 5 Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page iv FIGURE DIRECTORY Figure 1: Block diagram MBa8MP-RAS314 ................................9 Figure 2: Block diagram TQMa8MPxL .................................. 11 Figure 3: Block diagram I C bus ..................................... 12 Figure 4: Block diagram MBa8MP-RAS314 Reset structure ...........................
  • Page 6 Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page v REVISION HISTORY Rev. Date Name Pos. Modification 0001 11.10.2023 Kreuzer First edition 0002 04.03.2024 Kreuzer Figure 17 added Range corrected 0003 02.08.2024 Kreuzer 6.4, 6.5, 6.6, 6.7, 8.5...
  • Page 7: About This Manual

    Preliminary User's Manual, or due to usage of erroneous or incomplete information, are exempted, as long as there is no proven intentional or negligent fault of TQ-Systems GmbH. TQ-Systems GmbH explicitly reserves the rights to change or add to the contents of this Preliminary User's Manual or parts of it without special notification.
  • Page 8: Tips On Safety

    Handling and ESD tips General handling of your TQ-products The TQ-product may only be used and serviced by certified personnel who have taken note of the information, the safety regulations in this document and all related rules and regulations. A general rule is not to touch the TQ-product during operation. This is especially important when switching on, changing jumper settings or connecting other devices without ensuring beforehand that the power supply of the system has been switched off.
  • Page 9: Naming Of Signals

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 8 Naming of signals A hash mark (#) at the end of the signal name indicates a low-active signal. Example: RESET# If a signal can switch between two functions and if this is noted in the name of the signal, the low-active function is marked with a hash mark and shown at the end.
  • Page 10: Brief Description

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 9 BRIEF DESCRIPTION This Preliminary User's Manual describes the hardware of the MBa8MP-RAS314 as of revision 01xx. The MBa8MP-RAS314 is designed as a carrier board for the TQMa8MPxL. The TQMa8MPxL is directly soldered on the MBa8MP- RAS314.
  • Page 11: Mba8Mp-Ras314 Interfaces, Overview

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 10 MBa8MP-RAS314 interfaces, overview The following interfaces/functions and user interfaces are available on the MBa8MP-RAS314: Table 2: Data interfaces Interface Connector Type Remark Audio 1 × 3.5 mm jack...
  • Page 12: Electronics

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 11 ELECTRONICS MBa8MP-RAS314 functional groups The following chapters describe the interfaces of the MBa8MP-RAS314 in connection with a TQMa8MPxL. 3.1.1 TQMa8MPxL overview The MBa8MP-RAS314 provides all power supplies and configurations required for the operation of the TQMa8MPxL.
  • Page 13: I 2 C Devices, Address Mapping

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 12 3.1.3 C devices, address mapping The TQMa8MPxL provides five I C buses. Of these, only I2C3 and I2C5 are provided on a pin header. All other buses are used by different components on the module or the mainboard.
  • Page 14: Rtc Backup

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 13 3.1.4 RTC backup In case of power failure or power down, a Goldcap capacitor on the MBa8MP-RAS314 supplies the RTC on the TQMa8MPxL. The TQMa8MPxL features an i.MX 8M Plus-internal RTC or a discrete RTC PCF85063A. The RTC is supplied in either way.
  • Page 15: Power Supply

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 14 Table 6: Reset signals Signal Dir. Source Default Remark • Requires pull-up on carrier board (max. 6.5 V) RESET_OUT# TQMa8MPxL High • ON/OFF function; see i.MX 8M Plus data sheet (1)
  • Page 16: Protective Circuitry

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 15 3.2.1 Protective circuitry The protective circuit (see Figure 8) features the following characteristics: • Overcurrent protection by fuse 7 A, Slow Blow • Overvoltage protection • PI filter •...
  • Page 17: Communication Interfaces

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 16 Communication interfaces 3.3.1 Ethernet 1000 Base-T (RGMII) The i.MX 8M Plus CPU has two independent RGMII interfaces. On the MBa8MP-RAS314 both interfaces are used to provide two Gigabit Ethernet ports by means of two DP83867 Ethernet PHYs.
  • Page 18: Sd Card Interface

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 17 3.3.2 SD card interface The MBa8MP-RAS314 offers a microSD card slot that can also be used as boot source. All signals are directly connected to the USDHC2 interface of the i.MX 8M Plus.
  • Page 19: Usb 3.0 Hub

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 18 3.3.3 USB 3.0 Hub A USB 3.0 hub TUSB8041 is connected to the USB2 interface on the MBa8MP-RAS314, which provides four USB 3.0 / 2.0 host interfaces.
  • Page 20: Wifi

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 19 3.3.5 WiFi A WiFi module (LBEE5XV1YM from Murata) is available on the MBa8MP-RAS314. It supports IEEE 802.11 a/b/g/n/ac and offers a dual-band RF interface (2.4 / 5 GHz).
  • Page 21: Display Interface

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 20 Table 9: Pinout Camera Interface, X5 Signal Remark – MIPI_CSI1_DATA0_N – MIPI_CSI1_DATA0_P – – MIPI_CSI1_DATA1_N – MIPI_CSI1_DATA1_P – – MIPI_CSI1_CLK_N – MIPI_CSI1_CLK_P – – CAM_GPIO1 Enable...
  • Page 22 Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 21 TQMa8MPxL RESET, BLT_EN, PWR_EN, LVDS0 CONTRAST/PWM LVDS Data 5 V / 3.3 V 5 V / 12 V LVDS – Control 3.0 Hub optional Figure 13:...
  • Page 23: Hdmi

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 22 3.3.10 HDMI The HDMI_TX interface of the TQMa8MPxL is provided on the MBa8MP-RAS314 on an HDMI connector. Between TQMa8MPxL and HDMI socket is a "HDMI signal conditioning chip", which converts the levels and provides ESD protection. The HDMI_ARC_N and HDMI_ARC_P signals have capacitors between the module and the connector according to the EARC specification.
  • Page 24: Audio

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 23 3.3.11 Audio A Texas Instruments TLV320 audio codec is assembled. It is configured via SAI5 and controlled by the I2C4 bus. The audio codec provides microphone (mono) and headphone at a 3.5 mm jack on the MBa8MP-RAS314.
  • Page 25: Usdhc

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 24 3.3.17 USDHC The USDHC1 interface of the TQMa8MPxL is provided at the GPIO header of the MBa8MP-RAS314. It can be used as a 4-bit wide SDIO interface.
  • Page 26: User Interfaces And Diagnostic

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 25 User interfaces and diagnostic 3.4.1 Boot Mode configuration The Boot Mode is set with the 4-fold DIP switch S4 at the four i.MX 8M Plus pins Boot_Mode[3:0].
  • Page 27: Jtag

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 26 ® 3.4.4 JTAG ® ® ® The JTAG port of the i.MX 8M Plus is routed to a standard ARM 10-pin JTAG connector (X17) on the MBa8MP-RAS314.
  • Page 28: Software

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 27 SOFTWARE No software is required for the MBa8MP-RAS314. Suitable software is only required on the TQMa8MPxL and is not a part of this Preliminary User's Manual. More information can be found in the TQ-Support Wiki for the TQMa8MPxL.
  • Page 29: Component Placement & Labeling

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 28 Component placement & labeling Figure 18: MBa8MP-RAS314 component placement top...
  • Page 30 Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 29 Figure 19: MBa8MP-RAS314 component placement bottom The labels on the MBa8MP-RAS314 show the following information: Table 20: Labels on MBa8MP-RAS314 Label Content MBa8MP-RAS314 version and revision, tests performed...
  • Page 31: Safety Requirements And Protective Regulations

    TQ. TQ is not liable for any delivery delays due to national or international export restrictions or for the inability to make a delivery as a result of those restrictions.
  • Page 32: Climatic And Operational Conditions

    Page 31 Warranty TQ-Systems GmbH warrants that the product, when used in accordance with the contract, fulfills the respective contractually agreed specifications and functionalities and corresponds to the recognized state of the art. The warranty is limited to material, manufacturing and processing defects. The manufacturer's liability is void in the following cases: •...
  • Page 33: Environment Protection

    (Substances of very high concern, e.g., carcinogen, mutagen and/or persistent, bio accumulative and toxic). Within the scope of this juridical liability, TQ-Systems GmbH meets the information duty within the supply chain with regard to the SVHC substances, insofar as suppliers inform TQ-Systems GmbH accordingly.
  • Page 34: Appendix

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 33 APPENDIX Acronyms and definitions The following acronyms and abbreviations are used in this document: Table 22: Acronyms Acronym Meaning Analog/Digital Converter Artificial Intelligence ® Advanced RISC Machine...
  • Page 35 Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 34 Acronyms and definitions (continued) Table 23: Acronyms (continued) Acronym Meaning Media Access Controller Microphone MIPI Mobile Industry Processor Interface Machine Learning MTBF Mean operating Time Between Failures...
  • Page 36: References

    Preliminary User's Manual l MBa8MP-RAS314 UM 0003 l © 2024, TQ-Systems GmbH Page 35 References Table 23: Further applicable documents Name Rev. / Date Company i.MX 8M Plus Applications Processor Data Sheet Rev. 1 / 08/2021 i.MX 8M Plus Applications Processor Reference Manual Rev.
  • Page 37 TQ-Systems GmbH Mühlstraße 2 l Gut Delling l 82229 Seefeld Info@TQ-Group TQ-Group...

This manual is also suitable for:

Mba8mp-ras314-aaMba8mp-ras314

Table of Contents