Turnstiles KT-4 Installation Manual

Four-door controller
Hide thumbs Also See for KT-4:
Table of Contents

Advertisement

Quick Links

KT-4 Four-Door Controller
Installation Guide
Building Technologies and Solutions
A16381A195
2024-03-19
Rev. A
www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KT-4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Turnstiles KT-4

  • Page 1 KT-4 Four-Door Controller Installation Guide Building Technologies and Solutions A16381A195 2024-03-19 Rev. A www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 2 KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 3: Table Of Contents

    Connecting readers using Wiegand and modules using SPI............... 26 Connecting readers and modules using an RS-485 bus (with encrypted protocol)......26 Updating to the latest firmware......................26 Security configuration.........................26 Connecting to a network........................26 KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 4 Connecting a tamper switch......................35 Connecting the KT-4 over RS-485.......................35 Powering the KT-4............................38 Powering the KT-4 using PoE, PoE+, or PoE++................. 38 Powering the KT-4 using an external transformer................39 Powering the KT-4 using an internal transformer................39 Reset options..............................40 Soft reset...............................40...
  • Page 5 Creating a task builder action for audible and visual signals in EntraPass........54 Creating a trigger and alarm sound in EntraPass..................55 UL 294 Compliance Notice........................56 UL 2610 Compliance Notice........................56 End-User License Agreement........................58 Copyright.................................59 KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 6 KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 7: Safety Information

    WARNING: Risk of Electric Shock. Do not install the equipment during a lightning storm. This equipment, KT-4 Four-Door Controller Model KT-4-EU, shall be used installed and used within an environment that provides the pollution degree max 2 and over voltages category II non- hazardous locations, indoor only.
  • Page 8: Introduction

    Introduction The KT-4 four-door controller offers a simple access control and point monitoring solution. The following figures show the KT-4 PCB, inputs and outputs, and cabinets. Figure 1: KT-4 PCB KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 9 Figure 2: KT-4 inputs and outputs KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 10 USB type A connector to supported devices such as USB-485 communication device RJ12 low speed 1200-115200 RS232 serial interface RJ45 Ethernet network 10/100/1000 PoE, PoE+, or PoE++ with an installed PoE module KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 11 Figure 3: KT-4 cabinet for North America KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 12: Features

    Figure 4: KT-4 cabinet for global regions excluding North America Features The KT-4 controller includes the following features: Operating modes Use the KT-4 controller in one of the following modes: • Stand-alone mode: use as a stand-alone access controller with an Ethernet or Wi-Fi configuration for direct configuration.
  • Page 13: Compatibility With Entrapass

    When you use the KT-4 with any EntraPass edition, the first controller becomes the main controller and can poll up to 31 controllers. The KT-4 asynchronously polls the KT-1, KT-2, KT-4, or KT-400 controllers, and communicates with the EntraPass gateway only when it is necessary. This reduces the amount of bandwidth that the security system requires to operate on the network.
  • Page 14: Aes Encryption 128-Bit

    Lock outputs The KT-4 has four onboard lock outputs. You can configure any onboard or expansion module to perform the locking function. Lock outputs are supervised for open circuit or short to ground fault detection.
  • Page 15: Relay Outputs

    Relay outputs The KT-4 has four onboard relays. The four relays on the KT-4 board and any relays on optional expansion boards that attach through RS-485 are defined as local relay outputs. ioSmart card readers The KT-4 is compatible with ioSmart card readers, which provide security by using end-to-end encryption between the ID badge credentials and the EntraPass software.
  • Page 16: Technical Specifications

    Door strike power • 500 mA each or 2 A total for the KT-4 model AC power 75 VA (JP4 on INT) supervised • 750 mA each or 3 A total for the KT-4-EU model AC power 100 VA (JP4 on INT) •...
  • Page 17: Kt-4 Pcb Leds

    The design uses flash memory to save access rules. Note: The KT-4 Wi-Fi performance level depends on the type of router that you use and on the installation environment. The KT-4 Wi-Fi access point mode can be used for configuration: it requires a mobile, tablet, or laptop that has Wi-Fi capability and a web browser.
  • Page 18 KT-4, and blinking on Wi-Fi activity. Green The LED is steady on green when a Bluetooth device is associated with the KT-4, and blinking on communication activity. RS-232 RX Yellow The LED is blinking yellow if the RS-232 serial port is receiving activity from an integrated device.
  • Page 19: Vital Led

    4 short flashes Unable to 2 long flashes resolve DNS DHCP server 4 long flashes failed Note: To reset or change the KT-4 controller's communication mode, see Resetting the KT-4. KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 20: Wiring Diagrams

    Wiring diagrams The KT-4 monitors its power continuously, and reports low and critical power issues. Power outputs are monitored and are protected electronically against short-circuits and surges. Locking devices are monitored to detect open circuit or short to ground faults.
  • Page 21 Figure 5: KT-4 inputs and outputs, North American model KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 22: Power Supply For North American Model

    Main battery 12 VDC, 7 A/H, KT-BATT-12 Second battery 12 VDC, 7 A/H, KT-BATT-12 Power supply for North American model The mains input ratings are 120 VAC/60 Hz 16 or 24 VAC/75VA. KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 23 Figure 6: KT-4 inputs and outputs, global model KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 24: Power Supply For Global Model

    Note: The KT-4 global model is not validated by UL. System setup with EntraPass You can configure the KT-4 with EntraPass Special Edition, Corporate Edition, or Global Edition software in a number of ways. When you use the KT-4 with EntraPass Special Edition, Corporate multi-site gateway, or Global Edition gateway, you can configure the setup in the following ways: •...
  • Page 25: Security Hardening Guide

    When you use the KT-4 with EntraPass Global Edition and a KT-NCC-G2, you can configure the setup in the following ways: • Over the local area network (LAN) • Over the RS-485 with a VC-485 Security hardening guide The security hardening guide provides information about the following areas: •...
  • Page 26: Connecting To Entrapass Using Wi-Fi

    Connecting to a network Depending on your configuration and deployment architecture, you may require network access. For a convenient stand-alone deployment, you can configure the KT-4 over the network. • When you connect to the network, use a private LAN.
  • Page 27: Managing Users

    • Isolate the KT-4 system from networks of lower trust. Deployment To ensure the safe and secure deployment of the KT-4, see the following guidelines: • Restricting physical access to the controller • Logging on during the initial startup •...
  • Page 28: Installation

    For more information, see the following sections. 3. Connect the 16 or 24 VAC output from the 120 VAC 75 VA transformer with a KT-4, or the mains 230 VAC with a KT-4-EU. Alternatively, use a 24 VDC at 3.5 A power supply. If powered over Ethernet, connect the PoE, PoE+, or PoE++ to the RJ-45 connection.
  • Page 29: Earth Grounding

    Mounting hole, four total Earth grounding To ensure that the KT-4 controller operates effectively, provide earth grounding. 1. Connect the 18 AWG ground wire to the corresponding earth ground terminal. 2. Make an earth ground connection to the cabinet of the controller.
  • Page 30: Connecting Door Locking Devices

    Door locking device: 12 VDC to 13.75 VDC 1.5 A maximum when using internal power, jumper JP4 set to INT. Connect a 1000 Ohms resistor when you do not connect a door locking device. KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 31: Connecting Inputs

    Connecting inputs The KT-4 controller can monitor sixteen inputs. Each onboard input is supervised with or without 5.6K ohm end-of-line (EOL) resistors. The maximum distance of one line is 2,000 ft (600 m) with AWG #22 in a single or double EOL configuration.
  • Page 32: Connecting Card Readers

    Tamper Connecting card readers You can connect up to eight readers to a KT-4 controller. The controller provides 12 VDC power for card readers. The maximum distance between the readers and the controller varies by reader type. For more information, refer to the card reader Installation Guide.
  • Page 33 Figure 10: Wiegand or RS-485 reader configuration Callout Description COM2: RS-485 ioSmart mullion reader with integrated keypad on RS485 interface Rear view of the reader ioSmart single gang reader with integrated keypad on Wiegand interface KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 34 Figure 11: RS-485 daisy chain configuration Callout Description COM2: RS-485 ioSmart reader 1 Rear view of the reader ioSmart reader 8 KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 35: Connecting Relay Controlled Outputs

    Connecting relay controlled outputs The KT-4 controller provides four Form C relays that are rated at 3 Amps, 30 VDC, 0.6 power factor. Figure 12: KT-4 relay controlled outputs Connecting auxiliary outputs Connect auxiliary outputs to readers and local warning devices Auxiliary outputs are used for visual and audible signals.
  • Page 36 Note: If the VDC AUX- is already in use, connect the RS-485 signal ground to the other GND terminals on the KT-4. You cannot use the EGND terminal for signal ground. Only use the GND and AUX 12 VDC negative terminals for signal ground.
  • Page 37 Figure 13: Connecting the KT-4 over RS-485 KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 38: Powering The Kt-4

    During the installation, connect the Ethernet wire to the RJ-45 connector. Note: Use PoE, PoE+, or PoE++ Phihong model POE90U-1BT-1. Note: Do not use PoE, PoE+, or PoE++ if you intend to use the KT-4 as a wireless controller. KT-4 Four-Door Controller Installation Guide...
  • Page 39: Powering The Kt-4 Using An External Transformer

    1. Ensure you have a 16.5 or 24 VAC 75 VA transformer. 2. Place the batteries in the cabinet. 3. Connect the KT-4 AC power input to the transformer output, and connect the batteries. Note: If the AC supply is removed, the 12 VDC 7 Ah backup batteries support normal operation for up to 12 hours if fully charged.
  • Page 40: Reset Options

    Resetting the KT-4. Soft reset If you perform a soft reset on a KT-4, the following occurs: • If all of the controller's memory definitions and parameters are valid, they are verified and kept intact. If they are not valid, the controller goes into a hard reset.
  • Page 41: Factory Default Dhcp

    Note: When the LED is normally on and flashes off, it is a reversed flash. Factory default DHCP The KT-4 default DHCP is completed by Kantech. Reset the controller to factory default DHCP only for the following reasons: •...
  • Page 42: Spi Expansion Port

    Buzzer SPI expansion port Use the Serial Peripheral Interface (SPI) expansion port on the KT-4 to connect expansion modules in order to add more inputs and outputs, such as relays. The maximum current draw for the SPI expansion port is 500 mA when not using the 12 V AUX terminals. You must connect the 6-pin SPI cable to the SPI IN of the first module.
  • Page 43 Figure 17: KT-4 expansion modules KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 44 Relay module Buzzer Optional external high power source: 12-24 VDC Output device: 5-24 VDC, 1 A maximum 12 VDC, up to 0.75 A absolute total outputs, internal or external supply KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 45: Configuration

    If either of the devices are behind a bridged network, even if they have the same subnet, this step does not work. 4. On the KT-4 Registration page, to configure the correct mode, complete the steps in one of the following procedures: To configure the controller in stand-alone mode, complete one of the following options: •...
  • Page 46: Configuring The Kt-4 Using The Kt-Finder

    4. In the KT-Finder Wizard window, from the Device list, click KT-4. 5. In the MAC address field, type the MAC address of the KT-4, and click Connect. When the KT- Finder finds the controller, the following message appears: Configuring the KT-4 with the KT- Finder.
  • Page 47: Kt-4 Models, Expansion Kits, And Related Items

    AP mode (factory default). KT-4 models, expansion kits, and related items The following table lists all of the KT-4 controller models, expansion kits, and miscellaneous, related items. Table 7: KT-4 models, expansion kits, and related items...
  • Page 48 VC-485 interface, RS-232 cable 3 m (10 ft) with RJ-12 connectors, 740-1012 (DB25F to RJ-12) adapter, 740-1022 (DB9F to RJ-12) adapter and 740-1033 (DB25M to RJ-12) adapter TR1675 KT-4 transformer, wire-in, 110 VAC/16.5 VAC (75 VA), UL approved TR161000 KT-4-EU transformer, wire-in, 240 VAC/16 VAC (100 VA), CE approved KT-4-BATASSY...
  • Page 49: Kt-4 Maintenance Recommendations

    Do not try to recharge the battery. If you need to dispose of the PCB and/or the lithium battery, wrap the KT-4 in non-conductive tape. Check with your local authorities for battery disposal regulations.
  • Page 50: Europe, Middle East, And Africa

    +972 772 201 350 Italy Direct +39 0230 510 112 Direct +96 6800 8500 509 Kuwait Direct (0)22062915 Lebanon Direct 01 426 801, new dial tone and then dial 8552 3436 77 KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 51: Asia Pacific

    15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residen!al installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 52: Rf Transmitters: Compliance Statement (Part 15. 19)

    This equipment complies with RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 53: Warning (Part 15. 21)

    Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with the KT-4. Table 12: Antenna type Antenna type Antenna gain at 2.4 GHz and 5 GHz...
  • Page 54: Ce, Rcm, & Ukca

    8. Click Save and close the window. Note: Audible and visual signaling devices must be connected to the KT-4 relays and located near to the KT-4 controller. Depending on the audible or visual device you use, you may require an external power supply.
  • Page 55: Creating A Trigger And Alarm Sound In Entrapass

    Do not connect to a receptacle controlled by a switch. • Use of a UL 60950 or UL 62368 listed computer. • Use of a UL recognized tamper switch on every housing cabinet for the KT-4 Four-Door Controller. • Do not use the SmartLink option.
  • Page 56: Ul 294 Compliance Notice

    UL 2610 Compliance Notice • The KT-4 is UL 2610 Listed as a Commercial Proprietary Control Unit Accessory and Proprietary Burglar Alarm Unit (Section 83.2), with EntraPass and Redundant Server, alarm system features, EOL, KT-400 Controllers, Kantech ioProx Proximity readers, and TRex request to exit devices –...
  • Page 57 P225KPW26, P225XSF, P225KPXSF, P325W26, P325KPW26, P325XSF, P325KPXSF and P600; HID Signo 20NKS, 20TKS, 20KNKS, 20KTKS, 40NKS, 40TKS, 40KNKS, 40KTKS. Note: All P series readers can be ordered with or without the following suffixes: BEI, BEI-SE, GRY, or GRY-SE. KT-4 Four-Door Controller Installation Guide www.TURNSTILES.us | patrick.mcallister@TURNSTILES.us | 303-670-1099...
  • Page 58: End-User License Agreement

    The PoE/PoE+/PoE++ feature is not permitted for UL 2610. • The supervision of the IP network connection between a KT-4 and EntraPass is controlled by the network pulse time. You can program the network pulse time in EntraPass from 15 seconds up to 10 minutes.