Installation, Operation &
Maintenance
Instructions
9700 SERIES
Hydrostatic Level transmitter
SAFETY INSTRUCTIONS
Information
...points out useful tips,
recommendations and information
for efficient and trouble-free
operation.
CAUTION!
...indicates a potentially dangerous
situation that can result in light
injuries or damage to equipment or
the environment, if not avoided.
WARNING!
...indicates a potentially dangerous
situation that can result in serious
injury or death, if not avoided.
WARNING!
...identifies hazards caused by
electric power. Should the safety
instructions not be observed, there
is a risk of serious or fatal injury.
WARNING!
...indicates a potentially dangerous
situation that can result in burns,
caused by hot surfaces or liquids, if
not avoided.
WARNING!
...indicates a potentially dangerous
situation in the hazardous area that
can result in serious injury or death,
if not avoided.
Ex applications...special instructions for Ex
applications.
CONTENTS
Foreword
Product Overview
Operating principle
Specification
Installation
Wiring diagram
Replacement parts & maintenance
Fault finding
CSA Approval
CSA Control drawing
Integral cable length for I.S. circuits
Warranty
Decommissioning
Disposal
Product identification
Foreword
Product overview
The 9700 Series range of tank level transmitters
from Delta Mobrey, is a loop powered level transmitter.
It provides an accurate level measurement solution
where in-tank problems such as foaming, vapor layers,
and temperature gradients makes the use of other
instrumentation difficult.
The series comprises 3 different models for
measurement inside the tank and one for
measurement outside the tank with different
connections available, to meet the requirements of the
installation:
Models:
9710, 9720, 9780 for installation INSIDE the tank
Models:
9790 for installation OUTSIDE the tank
The transmitter is designed to withstand the harshest
of environments.
Its rugged, flush ceramic sensor is inherently capable
of withstanding attack from most chemicals.
Page 1 of 6
9710
Inside the
9720
tank
9780
Outside the
9790
tank
Warning: Units must be selected and installed by
suitably
trained
and
accordance with appropriate codes of practice so
that the possibility of failure resulting in injury or
damage caused by misuse or misapplication is
avoided.
Warning: Before installation check that the
characteristics of the chemical seal comply with
process and plant requirements
Warning: The user should ensure the equipment is
suitable for use in the application with aggressive
substances.
Warning: The users attention is drawn to the fact
that, when the unit is 'live' with respect to electrical
or pressure supplies, a hazard may exist if the unit
is opened or dismantled.
Warning: Do not try to disassemble the cable nor
the pole from the transmitter
Warning: Use appropriate tools for the installation
or the device.
Warning: Do not hang the instrument from the
cable!
IOM-9700 –B : MAY 2024
qualified
personnel
www.delta-mobrey.com
in

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9700 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for delta-mobrey 9700 Series

  • Page 1 Product overview substances. The 9700 Series range of tank level transmitters Warning: The users attention is drawn to the fact from Delta Mobrey, is a loop powered level transmitter. that, when the unit is ‘live’ with respect to electrical...
  • Page 2: Operating Principle

    0 to 328 ft. (0 to 100 m) H20 depth fitted 7.1 (16.4 / 5) 0 to 3.3 ft. (0 to 1 m) H20 depth 24.9 (57.4 / 17.5) 0 to 11.5 ft. (0 to 3.5 m) H20 depth Page 2 of 6 www.delta-mobrey.com...
  • Page 3 Submersible 9700 units are supplied fitted with a specified length of vented cable to be terminated in a vented box. For connection diagrams see below : 9790 • Black wire = negative • wire = positive • Screen cable must be connected Page 3 of 6 www.delta-mobrey.com...
  • Page 4: Csa Control Drawing

    High mA output Damaged Sensor (Voltage output sensor) approx. Return to factory. >10mA Replace sensor No Change in out- put with pressure change Page 4 of 6 www.delta-mobrey.com...
  • Page 5: Product Identification

    Isolate the instrument from the process. Disconnect the instrument from the process connection. Dismount the assembly and dispose -Warning: The process fluid can be hot and or corrosive. Plug the process pipe Product identification Model 9710 / 9720 Page 5 of 6 www.delta-mobrey.com...
  • Page 6 IOM-9700 –B : MAY 2024 Model 9780 Model 9790 Page 6 of 6 www.delta-mobrey.com...