    How to connect Atlas Junior with REALITi 360? ......................................... 11 How to change the Wi-Fi setting on Atlas Junior? ....................................... 14 FAQ ........................................................16 Spare Parts ..................................................... 17 Technical Data ....................................................17 Contact Information ..................................................17 ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | Contents...
  • Page 3: Product Introduction

    ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 PRODUCT INTRODUCTION Atlas Junior is the ALS pediatric simulator by 3B Scientific used for conducting interdisciplinary and interprofessional emergency training. It offers extensive emergency-specific applications for advanced life support in simulation-based training and further training.
  • Page 4: Features

    • REALITi 360 extends the therapy options to defibrillation, cardioversion and pacemaker application on the real or generic monitor. The bilateral carotid pulse feature allows to determine the indication and success of applied intervention. ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | Features...
  • Page 5: General Handling

    Wi-Fi connection has been established, a blue light appears when bluetooth speaker connection is established and a red light indicates that SSID name & password is ready to be changed. ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | General Handling | Safety Instructions | Installation...
  • Page 6: Airway

    BURP maneuver. To intubate use a classic laryngoscopy, or video laryngoscopy. è è è Recommended tube sizes: • Oraltracheal tube 5.5 • Nasotracheal tube 4.5 • iGel 2 • Laryngeal mask 2.5 • Laryngeal tube 2 ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | Airway...
  • Page 7 In order to see the inspiratory tidal volume use the quality CPR Dashboard and generic defibrillator screen from REALITi 360. è è è Lung Specification • Max tidal volume: 300 mL • Max airway pressure: 6.92 kpa ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | Airway...
  • Page 8: Cardiopulmonary Resuscitation (Cpr)

    ✓ Realistic compression depth and resistance ✓ Detection of depth, release, and frequency of compressions ✓ Real-time view of Quality of CPR on the CPR Dashboard ✓ Detection of hand position ✓ Compliant with ILCOR resuscitation ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | CPR...
  • Page 9: Circulation

    When the day’s sessions are done, flush the IV/IO/IM sites with air to remove any fluid/liquid in the system. Connect a syringe filled with air to the IV/IO/IM catheter and flush the IV pads/IO insert/IM insert with air until only air exits the overflow tube. Replacement of IV sites Replacement of IO/IM site ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | Circulation...
  • Page 10: Neurological

    Atlas Junior features a speaker integrated into the manikin. This speaker can be connected using the iSimulate iPad to access a variety of sounds from the REALITi sound library. ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | Neurological | Audio...
  • Page 11: Network/Router Settings

    4. Bluetooth Settings: Disable Bluetooth on the Monitor iPad, but enable it on the Control iPad to pair with Atlas Junior’s Bluetooth. ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | How to connect Atlas Junior with REALITi 360?
  • Page 12 8. Select a scenario or monitor and tap the ‘Start’ button. Launch the Defibrillator from the main menu on the iPad: scenario or monitor setup to begin. ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | How to connect Atlas Junior with REALITi 360?
  • Page 13 ‘Atlas Junior’ by tapping ‘Connect Device’. The connected the bar graph. Atlas Junior will be calibrated automatically. The manikins will simulate a carotid pulse. ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | How to connect Atlas Junior with REALITi 360?
  • Page 14: How To Change The Wi-Fi Setting On Atlas Junior

    Monitor iPad’s to reveal the ‘Available Devices’ menu. Select access the ‘Settings’. ‘Rescan Devices’ and choose ‘Atlas Junior Wi-Fi Config’ from the list by tapping ‘Connect Device.’ ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | How to change the Wi-Fi setting on Atlas Junior?
  • Page 15 Both iPads must be on the same Wi-Fi network. 10. Follow step 3 to step 12 from scenario 1. Junior is ready to start! ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | How to change the Wi-Fi setting on Atlas Junior?
  • Page 16: Faq

    • Open Settings on your iSimulate iPad and switch on Atlas Junior. • Tap Bluetooth. • Toggle Bluetooth on. • Select the device ‘BT...-Audio’ from the list. • Once connected, you’ll see the device listed as “Connected” under My Devices. ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | FAQ...
  • Page 17: Spare Parts

    CONTACT INFORMATION A worldwide group of companies 3B Scientific GmbH Ludwig-Erhard-Straße 20 • 20459 Hamburg • Germany Phone: +  49   (0)40-73966-0 • Fax: +  49   (0)40-73966-100 3bscientific.com • info@3bscientific.com ATLAS JUNIOR THE ALS PEDIATRIC SIMULATOR P76 | Spare Parts | Technical Data | Contact Information...