Haier HSU-18CK03 - annexe 1 Installation Manual page 5

Room air conditioner
Hide thumbs Also See for HSU-18CK03 - annexe 1:
Table of Contents

Advertisement

When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and tightened.
After the cable connection, never fail to fasten the connected cable with the wiring cover.
Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring
is not correct, proper operation can not be carried out and will cause defect.
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualified person. The type of connecting wire is H05RN-F or H07RN-F.
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the
distance between its two contacts should be not less than 3mm.
YEL/GRN
BLK
Indoor unit
WHT
HSU-09LE03
HSU-12LE03
HSU-05LE03
HSU-07LE03
YEL/GRN
BLK WHT
G
{
N
HSU-18LE03
L
HSU-22LE03
HSU-24LE03
Indoor unit
FJT-24L
Indoor unit
YEL/GRN
WHT
Outdoor unit
BLK
HSU-09LD0307
HSU-12LD0307
YEL/GRN
BLK
WHT
Outdoor unit
HSU-18CK0307
HSU-24CG0307
HSU-18CK03
FJT-18L
YEL/GRN
BLK
Indoor unit
WHT
Connecting wiring:
-mod 05-07-09-12: 3G1.0mm
-mod 18-22-24:
Power cable:
-mod 05-07-09-12: 3G1.0mm
-mod 18:
-mod 22-24:
5
YEL/GRN
BLK
WHT
Outdoor unit
HSU-12LX03
FJT-12L
2
3G2.0mm
2
2
3G1.5mm
2
3G2.5mm
2

Hide quick links:

Advertisement

Table of Contents
loading