Table of contents Before you start This is a compact, easy-to-setup, and easy-to-use wired conference system, yet it Before you start Web management system provides advanced features and excep onal versa lity. Embedded with advanced Introduc on………………………………... 1 Login page....…………………..14 network opera on system, configura on and control can be done via built-in web Features……………………………………….
Product overview Product overview Controller Front Panel Chairman unit 1. Condenser microphone capsule Detachable design, to pickup audio signal from speaker. 2. Mic indicator To indicate the working status of microphone. 3. Display 4. Volume control The volume control headset. 1.
Product overview Opera on System connec on diagram Controller system interface CONFERENCE CONTROL The menu includes various parameters setup related to pre-mee ng program. CAMERA TRACKING Configura on window which allows operator to configure the camera posi on for each microphone. RECORDING The window for audio recording opera on.
Opera on Opera on Conference control – Meet mode Conference control – Queue mode DISCUSSION MODE AUTO MODE Camera related setup, camera tracks to Camera related setup, camera tracks to the last switched on microphone unit. microphone unit which received voice FIFO signal.
Opera on Opera on ALL UNIT OFF/ON CERTAIN UNIT OFF/ON AUTO OFF TIME OFF All microphone units connected will be To switch on/off specific microphone unit To switch off the microphone when no To set the me frame for the microphone switched on/off.
Opera on Opera on Camera tracking Camera tracking – Setup preset CAMERA SETUP CAMERA NO. PRESET POINT Camera protocol: VISCA(SONY-D70)/Pelco- Select needed camera for the tracking Preset point is the unit ID that assigned for the tracking posi on configura on in the D/Pelco-P (baud rate:9600)/Yaan(baud posi on setup.
Opera on Opera on System setup Camera tracking – Preset proposal SETUP IP ADDRESS TIME System setup can be stored at this step as a proposal, different proposals can save and To define the IP for accessing web To configure the system me. retrieve when needed.
Web management system Web management system CERTAIN UNIT ADDRESS Login page To allow user to allocate a specific ID to a microphone unit. For example: A system consisted 30 mics, when an extra microphone to be included into the system, then user can define this mic’s ID as 31 separately. Note: Should only 1 microphone unit connected to the controller on this opera on.
Web management system Web management system MUTE AUTO OFF UNIT TIMING OFF TEST PRESET IEW PRESET To switch off the microphone when no To set the me frame for the microphone To allow user to check if the tracking To allow user to check the presets saved. voice unit in ac ve, the unit will be switched off...
Web management system General Specifica ons UNIT NAME interface allows operator to enter the name of attendee by clicking the Controller unit ID, then click“Save to device” to save as default name list. When user leaved this section and come back to this page, name list will not display until clicking “Load Power supply AC 110 - 220V/ 50 - 60Hz name”...
Page 12
General Specifica ons Microphone unit Power supply DC 24V Working current 60mA Cartridge Condenser Pa ern Cardioid Sensi vity -50dB/Pa Frequency response 100Hz - 12KHz 80dB Dynamic range 95dB Harmonic distor on <0.1% Input impedance 2.2K MIC length 540mm MIC - RJ45 X 1 Connector Earphone - 3.5mm x 1 Dimension...