Aprilaire AUV24V Installation & Operating Instructions Manual
Aprilaire AUV24V Installation & Operating Instructions Manual

Aprilaire AUV24V Installation & Operating Instructions Manual

Residential uvc coil cleaner
Hide thumbs Also See for AUV24V:

Advertisement

Quick Links

INSTALLATION & OPERATING INSTRUCTIONS
Model AUV24V
UVC
Residential UVC Coil Cleaner
Installed By:
Installer Phone:
Date Installed:
NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP
READ AND SAVE THESE INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AUV24V and is the answer not in the manual?

Questions and answers

Summary of Contents for Aprilaire AUV24V

  • Page 1 INSTALLATION & OPERATING INSTRUCTIONS Model AUV24V Residential UVC Coil Cleaner Installed By: Installer Phone: Date Installed: NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP READ AND SAVE THESE INSTRUCTIONS...
  • Page 2: Table Of Contents

    Internal Magnet Method                                         7 on the market, AprilAire UV units and systems use a process...
  • Page 3: Safety Instructions

    Always wear • This AprilAire UV unit is not waterproof. DO NOT INSTALL glasses/goggles and gloves when installing the unit. OUTDOORS OR IN A WET LOCATION.
  • Page 4: Setup

    WHAT’S INCLUDED IN THE BOX (SEE FIGURE 1) A. Ballast B. UVC lamp C. Magnetic multi-bracket QUICK INSTRUCTIONS D. Mounting hardware Model AUV24V Residential UVC Coil Cleaner E. Pair of cotton gloves F. Quick Instructions G. UV warning decal WARNING: H.
  • Page 5: Installation

    INSTALLATION FIGURE 2: MODEL AUV24V ON “A” COIL NOTE: SIDE INSTALLATION OF RETURN EXTERIOR BRACKET METHOD AUV24V ON “A” COIL IS ACCEPTABLE IF OPPOSITE COIL SUPPLY HAS ADEQUATE COVERAGE. SEE SIDE INSTALLATION DRAWING. WARNING “A” COIL 8” MIN. FROM LAMP TO TOP OF PRIOR TO BEGINNING INSTALLATION: “A”...
  • Page 6 6. Mount the back plate (FIGURE 5) to the ductwork using included self-tapping sheet metal screws. The flat side of the bracket FIGURE 5: BACK PLATE should contact the ductwork Ensure the center lamp hole aligns with the newly drilled hole to allow for lamp installation. Orient bracket housing into desired final position and secure with sheet metal screws in 2 mounting through holes 7.
  • Page 7: Internal Magnet Method

    (FIGURE 9). 1. Clear working area and unpack all included equipment from box; set aside on clear working space. Lamp should FIGURE 8: MODEL AUV24V ON “A” COIL remain in cardboard sleeve for protection until installed into bracket NOTE: SIDE INSTALLATION OF RETURN AUV24V ON “A”...
  • Page 8: Operation

    If using a separate 24 V transformer: a. Install transformer per manufacturers specifications. The AprilAire AUV24V is an automatic unit that is designed to run constantly when powered on As long as the blue b. Connect 24 V to the two black wires at the transformers glow can be seen through the viewport and the Ballast’s LED...
  • Page 9: Troubleshooting

    (measured in VA). Blinks 4 times Voltage to the • Install a dedicated transformer (AprilAire Part #8029 or other UL followed by a ballast is less approved transformer) that provides a minimum output of 20 VA at...
  • Page 10: Warning

    Step-down transformer 120 VAC to 24 VAC (40 VA) WARNING Use only specified AprilAire branded replacement UVC Lamps with your unit or system. Use of any other lamps will void your warranty and can result in damage to the unit,...
  • Page 11: Limited Warranty

    – 5:00 pm Central Time • Cosmetic damage or normal wear and tear, including, but not limited to: At the sole discretion of AprilAire, you may be required to: return the product not scratches, peeling finish, or dents that do not impede the mechanical later than thirty (30) days after the warranty period to the place of purchase or functionality of the product.
  • Page 12 B2209998B • 61002237 • 10.23 © 2023 AprilAire | aprilairepartners.com | 800.334.6011 AprilAire reserves the right to change specifications without notice.

Table of Contents